Product Information

SFM3300-D

SFM3300-D electronic component of Sensirion

Datasheet
Flow Sensors 250 slm, Bidirectional Digital Flow Meter designed for Medical Applications - Disposable Single Use Version

Manufacturer: Sensirion
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (AUD)

1: AUD 68.9469 ( AUD 75.84 Inc GST) ea
Line Total: AUD 68.9469 ( AUD 75.84 Inc GST)

307 - Global Stock
Ships to you between
Wed. 17 Jul to Fri. 19 Jul
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
303 - Global Stock


Ships to you between Wed. 17 Jul to Fri. 19 Jul

MOQ : 1
Multiples : 1

Stock Image

SFM3300-D
Sensirion

1 : AUD 68.9469
10 : AUD 54.4392
30 : AUD 54.4215
60 : AUD 53.5369
2520 : AUD 51.7854

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Accuracy
Housing Material
Output Type
Packaging
Range
Series
Type
Brand
Operation Mode
For Use With
Hts Code
Maximum Operating Temperature
Minimum Operating Temperature
Operating Supply Voltage
Product Type
Factory Pack Quantity :
Subcategory
Supply Voltage - Max
Supply Voltage - Min
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.

Datasheet SFM3300-D Datasheet SFM3300-AW Digital Flow Meter for medical applications Flow range: 250 slm, bidirectional Small dead space < 10ml Single use (-D) version Re-use (-AW) version Very fast update time (0.5ms) Product Summary The SFM3300 series is Sensirions digital flow meter series The SFM3300 series has been designed with the use by designed for medical applications. It measures the flow rate medical professionals in mind. It features medical cones of air, oxygen and other non-aggressive gases with for pneumatic connection to standard breathing circuits and superb accuracy. The special design of the flow channel a mechanical interface for easy and reliable electrical results in a very small dead space. reconnection. The sensor element, signal processing and digital calibration are on a single microchip assuring very The SFM3300-D is the disposable single-use Version. The fast signal processing time, best-in-class accuracy and re-use version SFM3300-AW withstands washing and superior robustness to rough handling and adverse autoclaving procedures. It is in development stage with conditions. specifications identical to SFM3300-D. Both versions are extremely well suited for proximal flow measurements in The well-proven and patented CMOSens sensor medical ventilation and other respiratory applications. technology is perfectly suited for high-quality mass production and is the ideal choice for demanding and cost- sensitive OEM applications. Sensor chip Applications The SFM3300 series flow meter features a fifth-generation Proximal Flow measurement silicon sensor chip. In addition to a thermal mass flow Expiratory flow measurement sensor element, the chip contains an amplifier, A/D For Ventilation & Anesthesia converter, EEPROM memory, digital signal processing Respiratory measurements circuitry, and interface. Due to seamless integration of Metabolic Measurements signal acquisition and processing on the single silicon die significant performance and cost benefits are achieved. OEM options A variety of custom options can be implemented for high- volume OEM applications (custom flow rates, calibration for other gases etc.). Contact us for more information. www.sensirion.com Version 1.2 January 2019 1/7 1 1.1 Physical specifications Parameter Condition Value Unit 2 Flow range -250 +250 slm 3 Typical Max 5 6 span <100 slm 3 5 % m.v. 4 5 6 Accuracy span >100 slm 7 10 % m.v. 5 2 offset 0.1 0.2 slm 8 6 span <25slm 2.0 2.5 % m.v 4,7 8 6 Noise Level span >25slm 3 5 % m.v 8 2 offset 0.1 0.2 slm 8 Accuracy shift for deviation from span 0.4 0.5 % m.v./10C 8 Reference temperature 25C offset 0.015 0.02 % m.v./10C 6 span 0.07 % m.v. Resolution (14bit) 2 offset 0.034 slm 8 60 slm 180 / 0.73 230 / 0.93 Pa / inH O 2 8 Pressure drop 100 slm 380 / 1.53 550 / 2.21 Pa / inH O 2 8 200 slm 1400 / 5.62 1900 / 7.63 Pa / inH O 2 1.2 Ambient conditions Parameter Condition Value Unit Calibrated Temperature Range Dry gas +10 +50 C Operating Temperature Range 10-95% rel. hum. (non cond.) +5 +50 C Recommended to use Extended Operating Range -20+5 C on-sensor heater Storage Temperature 10-95% rel. hum. (non cond.) -40 +70 C 15C - 35C 30 - 70 % rel. hum. Shelf Life for SFM3300-D 3 years storage in original packaging Operating Pressure Range absolute 0.54 1.1 bar Burst Overpressure gauge 0.3 bar 1.3 Media compatibility Parameter Value 9 Calibration Air Media Compatibility Air (non-condensing), N , O , other non- aggressive gases 2 2 Wetted Materials AW version Si, Si N , SiO , Gold, Epoxy, PPSU, silicone, stainless steel 3 4 x Wetted Materials D version Si, Si N , SiO , Gold, Epoxy, MABS, silicone 3 4 x 1 Reference conditions are temperature = 25C, absolute pressure = 966 mbar, horizontal flow and Vdd = 5V 2 slm: mass flow measured in liters per minute at standard conditions (T = 20 C, p = 1013.25 mbar) 3 forMa no sensor measured outside of this limits will be shipped and a CpK of 1.33 is targeted 4 For accuracy, noise level or resolution the total value is the sum of offset and span values 5 This value corresponds to a CpK of 0.67 (95% of sensors within the Typical limit) 6 %m.v. = % measured value = % of reading 7 Noise level defined as standard deviation of individual sensor readings, measured at full sampling rate 8 Average value 9 Contact Sensirion for information about other gases, wider calibrated temperature ranges and higher storage temperatures. www.sensirion.com Version 1.2 January 2019 2/7

Tariff Desc

8543.70.00 - Other machines and apparatus Free
13 No Signal processors (graphic equalisers, crossovers etc.)
91 .. Other

9027.10.00 Instruments and apparatus for physical or chemical analysis (for example, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes.

9031.80.00 - MEASURING OR CHECKING INSTRUMENTS, APPLIANCES AND MACHINES, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER; PROFILE PROJECTORS Other instruments, appliances and machines Free

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted