Product Information

DMM-4026-B-EB-R

DMM-4026-B-EB-R electronic component of PUI Audio

Datasheet
Audio IC Development Tools MEMS MICROPHONE EVALUATION BOARD OMNI -26 DB 1.8 VDC 1000uA

Manufacturer: PUI Audio
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (AUD)

1: AUD 7.4025 ( AUD 8.14 Inc GST) ea
Line Total: AUD 7.4025 ( AUD 8.14 Inc GST)

19 - Global Stock
Ships to you between
Fri. 26 Jul to Tue. 30 Jul
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
11 - Global Stock


Ships to you between Fri. 26 Jul to Tue. 30 Jul

MOQ : 1
Multiples : 1

Stock Image

DMM-4026-B-EB-R
PUI Audio

1 : AUD 6.1118
4 : AUD 6.0933
12 : AUD 5.9446
28 : AUD 5.8703

     
Manufacturer
Product Category
Category
Factory Pack Quantity :
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.

This document contains data proprietary to PUI Audio Inc. Any use or reproduction, in any form, without prior written permission of PUI Audio Inc. is prohibited. 2020, PUI Audio Inc. Data Sheet DMM-4026-B-EB-R PUI Audio is proud to release a line of high-fidelity MEMS wide-band microphones that cover 20 Hz up to 18 kHzand up to 20 kHz on some modelsand consistency of 1 dB across the entire frequency response. Quickly test and prototype the bottom-firing DMM-4026-B-EB-R with this evaluation board. Specifications Parameters Condition Values Units Directivity Omnidirectional 1 kHz 50cm with 94 dB source Sensitivity 0 dB=1V/Pa -261 dB Data Format 1/2 Cycle PDM Rated Voltage - 1.8 VDC Operating Voltage Range - 1.5 to 3.6 VDC Full Power Mode 820 ~ 1000 A Current Draw Low Power Mode 400 ~ 450 A Signal-to-Noise Ratio Full Power Mode 63 dB (1kHz, 94 dB input, A-weighted) Low Power Mode 61 dB Frequency Range 20~18,000 Hz Total Harmonic Distortion (typical) 94 dB 50cm, 1 kHz acoustic source 0.5% - Full Power Mode 123 dB Acoustic Overload Point SPL 50cm with 10% THD 1 kHz (AOP) Low Power Mode 120 dB SPL 50cm with 10% THD 1 kHz Environmental Compliances RoHS/Halogen Free 100 mVpp Square Wave Power Supply Rejection 217 Hz, A-weighted -86 dBFS Load Capacitance 140 pF Max Voltage on any Pin 4 VDC Maximum SPL Before Damage (Source 50cm from microphone) 160 dB Max Mechanical Shock 10,000 Gs Max Vibration Pre-MIL-STD-883 Method 2007, Test Condition B Operating Temp (VDD <3.0V) -40 ~ +100 C Operating Temp (VDD >3.0V) -40 ~ +70 C Storage Temperature -40 ~ +125 C PUI Audio, Inc., 3541 Stop Eight Road, Dayton, OH 45414 Tel: (937) 415-5901 Fax: (937) 415-5925 This document contains data proprietary to PUI Audio Inc. Any use or reproduction, in any form, without prior written permission of PUI Audio Inc. is prohibited. 2020, PUI Audio Inc. Operational Settings Parameters Condition Values Units Sleep Mode 0 ~ 250 kHz Clock Frequency Low Power Mode 500 ~ 800 kHz Full Power Mode 1.03 ~ 4.80 MHz For fCLK 2.4 MHz the duty cycle must be Duty Cycle in the range of 40 ~ 60% and for fCLK > 2.4 MHz the duty cycle must be 50% 40 ~ 60 % Logic Input High - 0.75*VDD ~ VDD + 0.3V Logic Input Low - -0.3 ~ 0.25*VDD Logic Output High - 0.75*VDD ~ VDD + 0.3V Logic Output Low - -0.3 ~ 0.25*VDD Timing Characteristics PUI Audio, Inc., 3541 Stop Eight Road, Dayton, OH 45414 Tel: (937) 415-5901 Fax: (937) 415-5925

Tariff Desc

8543.70.00 Other machines and apparatus Free
13 Signal processors (graphic equalisers, crossovers etc.) 91 Other Free

9027.10.00 Instruments and apparatus for physical or chemical analysis (eg, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes Free

9031.80.00 MEASURING OR CHECKING INSTRUMENTS, APPLIANCES AND MACHINES, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER; PROFILE PROJECTORS Other instruments, appliances and machines Free

9030.31.00 Oscilloscopes, spectrum analysers and other instruments and apparatus for measuring or checking electrical quantities, excluding meters of 9028; instruments and apparatus for measuring or detecting alpha, beta, gamma, x-ray, cosmic or other ionising radiations.
Other instruments and apparatus, for measuring or checking voltage, current, resistance or power Multimeters without a recording device Free

8473.30.00 Parts and accessories of the machines of 8471 AUTOMATIC DATA PROCESSING MACHINES AND UNITS THEREOF; MAGNETIC OR OPTICAL READERS, MACHINES FOR TRANSCRIBING DATA ONTO DATA MEDIA IN CODED FORM AND MACHINES FOR PROCESSING SUCH DATA, NOT ELSEWHERE SPECIFIED OR INCLUDED:
.Other 71 No Weighing less than 1kg Free

8537 BOARDS, PANELS, CONSOLES, DESKS, CABINETS AND OTHER BASES, EQUIPPED WITH TWO OR MORE APPARATUS OF 8535 OR 8536, FOR ELECTRIC CONTROL OR THE DISTRIBUTION OF ELECTRICITY, INCLUDING THOSE INCORPORATING INSTRUMENTS OR APPARATUS OF CHAPTER 90, AND NUMERICAL CONTROL APPARATUS, OTHER THAN SWITCHING APPARATUS OF 8517:
8538 PARTS SUITABLE FOR USE SOLELY OR PRINCIPALLY WITH THE APPARATUS OF 8535, 8536 OR 8537:
8538.10.10 22 For programmable controllers Free
PUI Audio Inc.
PUI Audio, Inc.

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted