Product Information

774500

774500 electronic component of Pilz

Datasheet
Module: safety relay; Series: PNOZ XV2; 24VDC; Contacts: NO x4

Manufacturer: Pilz
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (AUD)

1: AUD 708.0883 ( AUD 778.9 Inc GST) ea
Line Total: AUD 708.0883 ( AUD 778.9 Inc GST)

6 - Global Stock
Ships to you between
Thu. 11 Jul to Wed. 17 Jul
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
2 - Global Stock


Ships to you between Thu. 11 Jul to Wed. 17 Jul

MOQ : 1
Multiples : 1

Stock Image

774500
Pilz

1 : AUD 681.093
10 : AUD 679.35

     
Manufacturer
Product Category
IP Rating
Electrical Connection
Safety Category
Mounting
Input 1 Properties
Contacts Electrical Parameters
Type Of Module
Contacts Configuration
Series
Number Of Outputs
Operating Temperature
Supply Voltage
Number Of Inputs
Body Dimensions
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.

E-STOP relays, safety gate monitors Up to Category 4, EN 954-1 PNOZ XV2 Unit features E-STOP pushbuttons Safety gates Positive-guided relay outputs: The max. category the safety contacts 2 safety contacts (N/O), instanta- can achieve in accordance with neous EN 954-1 is stated in the technical de- 2 safety contacts (N/O), delay-on tails. de-energisation Connection options for: Safety features E-STOP pushbutton Safety gate limit switch The relay meets the following safety Reset button requirements: LED indicator for: The circuit is redundant with built-in Switch status channel 1/2 self-monitoring. Supply voltage The safety function remains effec- Safety relay for monitoring E-STOP Reset circuit tive in the case of a component fail- pushbuttons and safety gates. Delay-on de-energisation, fixed or ure. adjustable The correct opening and closing of Approvals Delay time can be cancelled via re- the safety function relays is tested set button automatically in each on-off cycle. See order reference for unit types The unit has an electronic fuse. PNOZ XV2 Unit description The safety relay meets the require- ments of EN 60947-5-1, EN 60204-1 and VDE 0113-1 and may be used in applications with Block diagram Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Strae 2, 73760 Ostfildern, Germany NSG-D-2-062-2010-01 Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh pilz.deE-STOP relays, safety gate monitors Up to Category 4, EN 954-1 PNOZ XV2 Function description earth faults in the reset and input Monitored reset: Unit is active once circuit, the input circuit is closed and once Single-channel operation: no re- short circuits in the input circuit the reset circuit is closed after the dundancy in the input circuit, earth and, with a monitored reset, in waiting period has elapsed faults in the reset circuit are detect- the reset circuit too, (see technical details). ed. shorts between contacts in the Increase in the number of available Dual-channel operation with detec- input circuit. contacts by connecting contact ex- tion of shorts across contacts: re- Automatic start: Unit is active once pander modules or external contac- dundant input circuit, detects the input circuit has been closed. tors/relays. Timing diagram Key Power: Supply voltage Output safe: Safety contacts, in- t : Delay-on de-energisation 2 Reset/start: Reset circuit S13-S14, stantaneous 13-14, 23-24 t : Delay time 3 S33-S34 Output safe del: Safety contacts, t : Waiting period 4 Reset t : Y39-Y40 delayed 37-38, 47-48 v t : Recovery time 5 c : Automatic reset Input: Input circuits S11-S12, S21- d : Monitored reset S22, S31-S32 t : Switch-on delay 1 Wiring Please note: Use copper wire that can withstand Information given in the Technical 60/75 C. details must be followed. Sufficient fuse protection must be Outputs 13-14, 23-24 are instanta- provided on all output contacts with neous safety contacts, outputs 37- capacitive and inductive loads. 38, 47-48 are delay-on de-energi- sation safety contacts. To prevent contact welding, a fuse should be connected before the output contacts (see technical de- tails). Calculation of the max. cable runs l in the input circuit: max R = max. overall cable resist- lmax ance (see technical details) R / km = cable resistance/km l Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Strae 2, 73760 Ostfildern, Germany NSG-D-2-062-2010-01 Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh pilz.de -2

Tariff Desc

8536.49.00 TC 17103979 RELAYS, PRINTED CIRCUIT BOARD

8536.41 TC 8909066 RELAYS, having a continuous contact rating of NOT less than 3A and body dimensions NOT exceeding 40mm x 30mm x 27mm

8536.49.00 TC 9613322 RELAYS, low profile, OTHER THAN reed relays, being EITHER of the following:
(a) height NOT exceeding 21.24 mm;
(b) height NOT exceeding 35 mm and having a continuous current rating NOT less than 8A AC

8536.49 TC 8906734 RELAYS, having ALL of the following:
(a) one, two or three contacts;
(b) maximum continuous contact current rating of NOT less than 15A;
(c) maximum contact voltage rating of NOT less than 380V;
(d) maximum switched power rating of NOT less than 4000VA

8536.49.00 TC 1122469 RELAYS, having an operating voltage NOT exceeding 250 volts, having ANY of the following:
(a) spring loaded terminals
(b) plug-in screw terminals
(c) wire connected terminals

8536.41 TC 8534635 RELAYS, cradle, having ALL of the following:
(a) maximum switching current NOT exceeding 5 A (AC or DC);
(b) switching voltage NOT exceeding 250 V (AC or DC);
(c) body dimensions NOT exceeding 31 mm x 36 mm x 19 mm

8536.49 TC 8633667 RELAYS, vacuum, hermetically sealed

8536.41.00 TC 19144923 RELAYS, SWITCH AMPLIFIER, having a supply voltage NOT greater than 40v

8536.49 8633669 RELAYS, thermal overload, having ALL of the following characteristics:
(a) trip time NOT exceeding 5 s at 6 times full load current
(b) manual reset
(c) maximum current 50A

8536.49 TC 8633636 RELAYS, power appliance, 15A, having EITHER 2 contacts or 3 contacts

8536.41 TC 8438513 RELAYS, mercury wetted, contact type

8536.41 TC 8438500 RELAYS, coaxial

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted