Product Information

050R20-102B

050R20-102B electronic component of Parlex

Datasheet
Flat Cables .5mm-20-4-B ZIF .5mm Pitch Cable

Manufacturer: Parlex
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (AUD)

1: AUD 11.3215 ( AUD 12.45 Inc GST) ea
Line Total: AUD 11.3215 ( AUD 12.45 Inc GST)

982 - Global Stock
Ships to you between
Fri. 26 Jul to Tue. 30 Jul
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
930 - Global Stock


Ships to you between Fri. 26 Jul to Tue. 30 Jul

MOQ : 1
Multiples : 1

Stock Image

050R20-102B
Parlex

1 : AUD 7.7315
10 : AUD 6.6523
25 : AUD 5.7677
50 : AUD 5.1662
100 : AUD 4.9892
250 : AUD 4.2462
500 : AUD 3.6623
1000 : AUD 3.4146
2500 : AUD 3.3262

     
Manufacturer
Product Category
Product
Number of Conductors
Conductor Spacing
Cable Length
Insulation Material
Conductor Material
Maximum Operating Temperature
Minimum Operating Temperature
Packaging
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.

PROPRIETARY INFORMATION NOTICE This document and the designs, specifications, and engineering information disclosed herein are the property of Parlex USA LLC and are not to be disseminated or reproduced without expressed written consent. This document is loaned in confidence and then Standard ZIF Cable - Same side exposure only for consideration of the matter disclosed hereon. In accepting loan of this document, the recipient agrees to keep it and the matter disclosed hereon in confidence and not to use or permit their use in any way detrimental to Parlex USA LLC Cable Length Exposed Conductor Stiffener Margin Pitch Standard Part Numbering Configuration Cable Width Span XXX R X X - X XXXXX - 15 Characters maximum Conductor Width Marking - See Note Mating Thickness Cable Pitch Method Notes: 050 = 0.50MM ( 0.0197 ) - = Standard Cable Width = ( of conductors +1)*( Pitch ) 062 = 0.625MM ( 0.0246 ) Span = ( of conductors -1 )*( Pitch ) Space ( 1 space between orientation and method ) 100 = 1.00MM ( 0.0394 ) Mating Thickness = .012 ( .305mm ) 125 = 1.25MM ( 0.0492 ) Insulation = .002 Polyester with .0015 Flame Retardent Adhesive Conductors = Copper Tin Plated 127 = 1.27MM ( 0.050 ) Orientation of cable ends ( See Sheet 2 ) Temperature rating = -55C to 105C 254 = 2.54MM ( 0.100 ) Dielectric Strength = 2500 Volts/Mil Cable length in MM ( Up to 4 spaces, No decimal points ) UL Flame Rating = VW-1 R = RoHS Compliant Insulation Resistance = 10 Megaohm min. Standard Marking - Minimum marking to be PARLEX and Date Cod. On cables where Dimension of Conductors Tolerances - ( Dash ) spacing does not allow parts will not be marked. ( 1 - 99 ) See below note 0-3 .050 (1.27mm) 3 -6 .060 (1.524mm) ( For cables with less than 10 6 -12 .070 (1.778mm) Current Exposed Stiffener Copper CopperCopper UL Pitch Margin Conductors use only 1 number 12 -18 .110 (2.794mm) Conductor Length Thickness WidthWidth Style Rating 18 -24 .120 (3.048mm) Ex. 100R8-1252B - ) .0197 (.500mm) .014 (.356mm) .140 (3.556mm) .011 (.280mm) 20890 .237 (6mm) .003 (.076mm) .50 AMPS 24 -36 .150 (3.810mm) .0246 (.625mm) .017 (.422mm) .140 (3.556mm) .237 (6mm) .003 (.076mm) .016 (.406mm) 20890 .50 AMPS Over 36 .025 (.635mm) .020 (.495mm) .140 (3.556mm) .011 (.280mm) 1% OF LENGTH .237 (6mm) .003 (.076mm) 20890 .50 AMPS Exposed Conductor Length .030 (.76MM) .0315 (.800mm) .023 (.572mm) .140 (3.556mm) .237 (6mm) .003 (.076mm) .019 (.483mm) 20566 .80 AMPS .0394 (1.00mm) .026 (.660mm) .140 (3.556mm) .237 (6mm) .003 (.076mm) .026 (.660mm) 20566 Stiffener Length .050 (1.27MM) 1.5 AMPS .0492 (1.25mm) .033 (.845mm) .170 (4.318mm) .294 (7.5mm) .003 (.076mm) .0315 (.800mm) 20566 & 2643 2.0 AMPS Pitch .005 (.127MM) .050 (1.27mm) .034 (.864mm) .170 (4.318mm) .0315 (.800mm) Span .294 (7.5mm) .003 (.076mm) 20566 & 2643 2.0 AMPS .005 (.127MM) .100 (2.54mm) .069 (1.753mm) .240 (6.096mm) .062 (1.575mm) 2643 3.0 AMPS Margin .005 (.127MM) .394 (10mm) .003 (.076mm) A Johnson Electric Company .005 (.127MM) Cable Width UL Style Notes Parlex Standard ZIF Style Cables Part Numbering Configurations and General Specifications 20890 = .008 Min spacing between conductors, Voltage rating = 90 Volts SIZE FSCM Rev. SIZE FSCM Rev. 20566 = .010 Min spacing between conductors, Voltage rating = 90 Volts PS-3705 PS-3705 B 18377 - B 18377 - 2643 = .016 Min spacing between conductors, Voltage rating = 300 Volts SCALE NA SHEET 3 OF 4 SCALE NA SHEET 1 OF 4 Cables in piece form Standard ZIF Cable - Reverse side exposure Cable end orientations B Cable Length ZIF with Stiffeners on both ends Exposed Conductor Cables in bulk form Margin Stiffener BN ZIF with Stiffener on one end only Pitch KK Bulk roll with no exposed conductors and no stiffeners Cable Width Span BO ZIF with Stiffeners both ends Opposite sides Conductor Width 0.112 Ref. KS Bulk roll with no exposed conductors and no stiffeners with stripe marked over first conductor Bussbar Mating Thickness Cable Length Marking - See Note 0.280 0.030 Lasered Area Notes: BL KW Cable Width = ( of conductors +1)*( Pitch ) ZIF with Stiffeners one end and Lasered one end Bulk roll with exposed conductors and stiffeners Span = ( of conductors -1 )*( Pitch ) Mating Thickness = .012 ( .305mm ) Insulation = .002 Polyester with .0015 Flame Retardent Adhesive BT KN ZIF with Stiffener one end and Blunt cut one end Bulk roll with exposed conductors and no stiffeners Conductors = Copper Tin Plated Temperature rating = -55C to 105C Dielectric Strength = 2500 Volts/Mil N ZIF with no Stiffeners KR UL Flame Rating = VW-1 Bulk roll with exposed conductors and stiffeners on opposite sides Insulation Resistance = 10 Megaohm min. Standard Marking - Minimum marking to be PARLEX and Date Cod. On cables where Dimension Tolerances Double Exposed Area spacing does not allow parts will not be marked. NO ZIF with no Stiffeners Opposite sides .075 (1.905mm) 0-3 KL .100 (2.54mm) Bulk roll with exposed conductors with stiffeners and double bare area 3 -6 .125 (3.175mm) 6 -12 0.112 Ref. Exposed CopperCopper UL Current Stiffener Copper Bussbar Pitch Margin 12 -18 .150 (3.810mm) Cable Length Conductor Length Thickness WidthWidth Style Rating 0.280 0.030 18 -24 .200 (5.08mm) KBN .0197 (.500mm) .014 (.356mm) .140 (3.556mm) .237 (6mm) .003 (.076mm) .011 (.280mm) 20890 .50 AMPS Lasered Area Bulk roll with exposed conductors and stiffeners every other window 24 -36 .250 (6.35mm) .0246 (.625mm) .017 (.422mm) .140 (3.556mm) .016 (.406mm) 20890 .237 (6mm) .003 (.076mm) .50 AMPS NL 1% OF LENGTH Over 36 ZIF with no Stiffener one end and Lasered one end .025 (.635mm) .020 (.495mm) .140 (3.556mm) .237 (6mm) .003 (.076mm) .011 (.280mm) 20890 .50 AMPS .0315 (.800mm) .023 (.572mm) .140 (3.556mm) .003 (.076mm) .019 (.483mm) 20566 Exposed Conductor Length .030 (.76MM) .237 (6mm) .80 AMPS KNO Stiffener Length .050 (1.27MM) .0394 (1.00mm) .026 (.660mm) .140 (3.556mm) .237 (6mm) .003 (.076mm) .026 (.660mm) 20566 1.5 AMPS Bulk roll with exposed conductors and no stiffeners opposite sides .003 (.076mm) .0315 (.800mm) 20566 & 2643 Pitch .005 (.127MM) .0492 (1.25mm) .033 (.845mm) .170 (4.318mm) .294 (7.5mm) 2.0 AMPS .050 (1.27mm) .034 (.864mm) .170 (4.318mm) .003 (.076mm) .0315 (.800mm) 20566 & 2643 2.0 AMPS Span .005 (.127MM) .294 (7.5mm) NT ZIF with no Stiffener one end and Blunt cut one end .062 (1.575mm) .100 (2.54mm) .069 (1.753mm) .240 (6.096mm) .394 (10mm) .003 (.076mm) 2643 3.0 AMPS Margin .005 (.127MM) KRN Bulk roll with exposed conductors and stiffeners every other window opposite sides .005 (.127MM) Cable Width 0.112 Ref. UL Style Notes Bussbar Cable Length 20890 = .008 Min spacing between conductors, Voltage rating = 90 Volts L 0.280 0.030 Lasered Area SIZE FSCM Rev. 20566 = .010 Min spacing between conductors, Voltage rating = 90 Volts PS-3705 Lasered cable both ends 18377 B - 2643 = .016 Min spacing between conductors, Voltage rating = 300 Volts SHEET 4 OF 4 SCALE NA SIZE FSCM Rev. PS-3705 TT B 18377 - Cable Blunt cut both ends SCALE NA SHEET 2 OF 4 Cable Length Cable LengthPROPRIETARY INFORMATION NOTICE This document and the designs, specifications, and engineering information disclosed herein are the property of Parlex USA LLC and are not to be disseminated or reproduced without expressed written consent. This document is loaned in confidence and then Standard ZIF Cable - Same side exposure only for consideration of the matter disclosed hereon. In accepting loan of this document, the recipient agrees to keep it and the matter disclosed hereon in confidence and not to use or permit their use in any way detrimental to Parlex USA LLC Cable Length Exposed Conductor Stiffener Margin Pitch Standard Part Numbering Configuration Cable Width Span XXX R X X - X XXXXX - 15 Characters maximum Conductor Width Marking - See Note Mating Thickness Cable Pitch Method Notes: 050 = 0.50MM ( 0.0197 ) - = Standard Cable Width = ( of conductors +1)*( Pitch ) 062 = 0.625MM ( 0.0246 ) Span = ( of conductors -1 )*( Pitch ) Space ( 1 space between orientation and method ) 100 = 1.00MM ( 0.0394 ) Mating Thickness = .012 ( .305mm ) 125 = 1.25MM ( 0.0492 ) Insulation = .002 Polyester with .0015 Flame Retardent Adhesive Conductors = Copper Tin Plated 127 = 1.27MM ( 0.050 ) Orientation of cable ends ( See Sheet 2 ) Temperature rating = -55C to 105C 254 = 2.54MM ( 0.100 ) Dielectric Strength = 2500 Volts/Mil Cable length in MM ( Up to 4 spaces, No decimal points ) UL Flame Rating = VW-1 R = RoHS Compliant Insulation Resistance = 10 Megaohm min. Standard Marking - Minimum marking to be PARLEX and Date Cod. On cables where Dimension of Conductors Tolerances - ( Dash ) spacing does not allow parts will not be marked. ( 1 - 99 ) See below note 0-3 .050 (1.27mm) 3 -6 .060 (1.524mm) ( For cables with less than 10 6 -12 .070 (1.778mm) Current Exposed Stiffener Copper CopperCopper UL Pitch Margin Conductors use only 1 number 12 -18 .110 (2.794mm) Conductor Length Thickness WidthWidth Style Rating 18 -24 .120 (3.048mm) Ex. 100R8-1252B - ) .0197 (.500mm) .014 (.356mm) .140 (3.556mm) .011 (.280mm) 20890 .237 (6mm) .003 (.076mm) .50 AMPS 24 -36 .150 (3.810mm) .0246 (.625mm) .017 (.422mm) .140 (3.556mm) .237 (6mm) .003 (.076mm) .016 (.406mm) 20890 .50 AMPS Over 36 .025 (.635mm) .020 (.495mm) .140 (3.556mm) .011 (.280mm) 1% OF LENGTH .237 (6mm) .003 (.076mm) 20890 .50 AMPS Exposed Conductor Length .030 (.76MM) .0315 (.800mm) .023 (.572mm) .140 (3.556mm) .237 (6mm) .003 (.076mm) .019 (.483mm) 20566 .80 AMPS .0394 (1.00mm) .026 (.660mm) .140 (3.556mm) .237 (6mm) .003 (.076mm) .026 (.660mm) 20566 Stiffener Length .050 (1.27MM) 1.5 AMPS .0492 (1.25mm) .033 (.845mm) .170 (4.318mm) .294 (7.5mm) .003 (.076mm) .0315 (.800mm) 20566 & 2643 2.0 AMPS Pitch .005 (.127MM) .050 (1.27mm) .034 (.864mm) .170 (4.318mm) .0315 (.800mm) Span .294 (7.5mm) .003 (.076mm) 20566 & 2643 2.0 AMPS .005 (.127MM) .100 (2.54mm) .069 (1.753mm) .240 (6.096mm) .062 (1.575mm) 2643 3.0 AMPS Margin .005 (.127MM) .394 (10mm) .003 (.076mm) A Johnson Electric Company .005 (.127MM) Cable Width UL Style Notes Parlex Standard ZIF Style Cables Part Numbering Configurations and General Specifications 20890 = .008 Min spacing between conductors, Voltage rating = 90 Volts SIZE FSCM Rev. SIZE FSCM Rev. 20566 = .010 Min spacing between conductors, Voltage rating = 90 Volts PS-3705 PS-3705 B 18377 - B 18377 - 2643 = .016 Min spacing between conductors, Voltage rating = 300 Volts SCALE NA SHEET 3 OF 4 SCALE NA SHEET 1 OF 4 Cables in piece form Standard ZIF Cable - Reverse side exposure Cable end orientations B Cable Length ZIF with Stiffeners on both ends Exposed Conductor Cables in bulk form Margin Stiffener BN ZIF with Stiffener on one end only Pitch KK Bulk roll with no exposed conductors and no stiffeners Cable Width Span BO ZIF with Stiffeners both ends Opposite sides Conductor Width 0.112 Ref. KS Bulk roll with no exposed conductors and no stiffeners with stripe marked over first conductor Bussbar Mating Thickness Cable Length Marking - See Note 0.280 0.030 Lasered Area Notes: BL KW Cable Width = ( of conductors +1)*( Pitch ) ZIF with Stiffeners one end and Lasered one end Bulk roll with exposed conductors and stiffeners Span = ( of conductors -1 )*( Pitch ) Mating Thickness = .012 ( .305mm ) Insulation = .002 Polyester with .0015 Flame Retardent Adhesive BT KN ZIF with Stiffener one end and Blunt cut one end Bulk roll with exposed conductors and no stiffeners Conductors = Copper Tin Plated Temperature rating = -55C to 105C Dielectric Strength = 2500 Volts/Mil N ZIF with no Stiffeners KR UL Flame Rating = VW-1 Bulk roll with exposed conductors and stiffeners on opposite sides Insulation Resistance = 10 Megaohm min. Standard Marking - Minimum marking to be PARLEX and Date Cod. On cables where Dimension Tolerances Double Exposed Area spacing does not allow parts will not be marked. NO ZIF with no Stiffeners Opposite sides .075 (1.905mm) 0-3 KL .100 (2.54mm) Bulk roll with exposed conductors with stiffeners and double bare area 3 -6 .125 (3.175mm) 6 -12 0.112 Ref. Exposed CopperCopper UL Current Stiffener Copper Bussbar Pitch Margin 12 -18 .150 (3.810mm) Cable Length Conductor Length Thickness WidthWidth Style Rating 0.280 0.030 18 -24 .200 (5.08mm) KBN .0197 (.500mm) .014 (.356mm) .140 (3.556mm) .237 (6mm) .003 (.076mm) .011 (.280mm) 20890 .50 AMPS Lasered Area Bulk roll with exposed conductors and stiffeners every other window 24 -36 .250 (6.35mm) .0246 (.625mm) .017 (.422mm) .140 (3.556mm) .016 (.406mm) 20890 .237 (6mm) .003 (.076mm) .50 AMPS NL 1% OF LENGTH Over 36 ZIF with no Stiffener one end and Lasered one end .025 (.635mm) .020 (.495mm) .140 (3.556mm) .237 (6mm) .003 (.076mm) .011 (.280mm) 20890 .50 AMPS .0315 (.800mm) .023 (.572mm) .140 (3.556mm) .003 (.076mm) .019 (.483mm) 20566 Exposed Conductor Length .030 (.76MM) .237 (6mm) .80 AMPS KNO Stiffener Length .050 (1.27MM) .0394 (1.00mm) .026 (.660mm) .140 (3.556mm) .237 (6mm) .003 (.076mm) .026 (.660mm) 20566 1.5 AMPS Bulk roll with exposed conductors and no stiffeners opposite sides .003 (.076mm) .0315 (.800mm) 20566 & 2643 Pitch .005 (.127MM) .0492 (1.25mm) .033 (.845mm) .170 (4.318mm) .294 (7.5mm) 2.0 AMPS .050 (1.27mm) .034 (.864mm) .170 (4.318mm) .003 (.076mm) .0315 (.800mm) 20566 & 2643 2.0 AMPS Span .005 (.127MM) .294 (7.5mm) NT ZIF with no Stiffener one end and Blunt cut one end .062 (1.575mm) .100 (2.54mm) .069 (1.753mm) .240 (6.096mm) .394 (10mm) .003 (.076mm) 2643 3.0 AMPS Margin .005 (.127MM) KRN Bulk roll with exposed conductors and stiffeners every other window opposite sides .005 (.127MM) Cable Width 0.112 Ref. UL Style Notes Bussbar Cable Length 20890 = .008 Min spacing between conductors, Voltage rating = 90 Volts L 0.280 0.030 Lasered Area SIZE FSCM Rev. 20566 = .010 Min spacing between conductors, Voltage rating = 90 Volts PS-3705 Lasered cable both ends 18377 B - 2643 = .016 Min spacing between conductors, Voltage rating = 300 Volts SHEET 4 OF 4 SCALE NA SIZE FSCM Rev. PS-3705 TT B 18377 - Cable Blunt cut both ends SCALE NA SHEET 2 OF 4 Cable Length Cable Length

Tariff Desc

8544.42.29 CABLES, COMPUTER, being ANY of the following:
(a) flat ribbon;
(b) audio;
(c) video;
(d) serial interface;
(e) light emitting diode
(LED) strip;
(f) data;
(g) local area network;
(h) internal drive;
(i) switch (jumper);
(j) modulator/demodulator (MODEM);
(k) planar to modulator/demodulator (MODEM);
(l) signal
Op. 01.01.2007 Dec. 22.11.2006 - TC 0614493

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted