9V (6LR61XWA)
Industrial
Part Number: 6LR61XWA
(Replaces Panasonic part number 6AM-6PI)
Alkaline-Zinc/Manganese Dioxide
Industry Standard Dimensions mm (inches)
Dimensions Comply with ANSI and IEC Standards Specifications
Chemical Alkaline-Zinc/Manganese Dioxide
Max. inch Min. inch
System: (Zn/MnO2)
A 1.909 1.831
Designation: ANSI 1604A, IEC 6LR61
Nominal
B 1.827
9.0V
Voltage:
Operating
C 1.043 .965
Temperature -20C to 54C (-4F to 130F)
Range:
D .689 .610
Typical
45 grams (1.6 oz.)
Weight:
E .510 .490
Typical
3 3
22.8 cm (1.39 in. )
Volume:
Terminals: Snap
Batteries for every application and industry including:
Shelf Life: 5 years (85% Capacity)
Medical Hotel/Motel/Restaurant Transportation
Communications Government/Municipality HVAC
Heavy Metals No added Mercury,
Contractors Janitorial/Sanitation Power Plants
Content: Cadmium or Lead
Manufacturing Military/Defense Security
Important Notice: This data sheet contains typical information specific to products manufactured at the time of its publication.
Photos represent typical industrial applications but may or may not match the battery size on this data sheet.
Page 1 of 29V (6LR61XWA)
Industrial
Part Number: 6LR61XWA (Replaces Panasonic part number 6AM-6PI)
Alkaline-Zinc/Manganese Dioxide
Typical Discharge Characteristics with Typical Discharge Characteristics with Typical Temperature Characteristics
Constant Current at 20C Constant Resistance at 20C 5.4 Volts Cutoff Voltage
IEC/ANSI Standard Tests @ 20C
9V 9V
Toy (270ohm 1hpd) Smoke Detector, Accelerated Test (10K/620ohm 1sph pulse)
10
9.5
9
9
8.5
8
8
7
7.5
6
7
0 5 10 15 20 30 40
5
0 5 10 15 20 25
Duration (Days)
Duration (Hours)
9V Radio (620ohm 2hpd)
10
9
8
7
6
5
0 10 20 30 40 50 60
Duration (Hours)
This information is generally typical and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to modification
without notice. Cell/battery performance and service life depends on the operating temperature, cut-off voltage and load applied to cell/battery in a specific application. It is the responsibility of each user to ensure that each
cell/battery application is adequately designed safe and compatible with all conditions encountered during use and in conformance with existing standards and requirements. Contact Panasonic for the latest information.
2009 Panasonic Energy Corporation of America. All rights reserved. All reproductions prohibited without proper authorization.
Characteristics and specifications subject to change without prior notification.
Panasonic Energy Corporation of America Panasonic Canada Inc.
www.panasonic.com/industrial/battery/industrial www.panasonic.ca
e-mail: batteries@us.panasonic.com e-mail: ind_batteries@ca.panasonic.com
Page 2 of 2 Form 9VInd PEC-2.2009
Voltage (CCV) Voltage (CCV)
Voltage (CCV)