Product Information

PYP-1

PYP-1 electronic component of Omron

Datasheet
Relay Sockets & Hardware SOCKET PLATE FOR LY/MY

Manufacturer: Omron
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (AUD)

50: AUD 0.8152 ( AUD 0.9 Inc GST) ea
Line Total: AUD 40.76 ( AUD 44.84 Inc GST)

1063 - Global Stock
Ships to you between
Mon. 22 Jul to Fri. 26 Jul
MOQ: 50  Multiples: 1
Pack Size: 1
Availability Price Quantity
1063 - Global Stock


Ships to you between Mon. 22 Jul to Fri. 26 Jul

MOQ : 50
Multiples : 1

Stock Image

PYP-1
Omron

50 : AUD 0.8152
500 : AUD 0.6585
1000 : AUD 0.6486
2500 : AUD 0.6092
5000 : AUD 0.583
7500 : AUD 0.5743
10000 : AUD 0.5656
15000 : AUD 0.5571

64 - Global Stock


Ships to you between Fri. 26 Jul to Tue. 30 Jul

MOQ : 1
Multiples : 1

Stock Image

PYP-1
Omron

1 : AUD 0.8341
10 : AUD 0.8174
25 : AUD 0.7561
50 : AUD 0.7301
100 : AUD 0.6818
300 : AUD 0.6298
500 : AUD 0.5907
1000 : AUD 0.5888
2500 : AUD 0.5721

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Accessory Type
Associated Relay Series
Termination Style
Width
Application
Packaging
Brand
Mounting Style
Factory Pack Quantity :
Cnhts
Hts Code
Mxhts
Product Type
Subcategory
Taric
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.

Solid-state Timer H3Y CSM H3Y DS E 7 2 Miniature Timer Compatible with the MY Relay Semi-multi power supply voltage. Large transparent time setting knob facilitates time setting. A flat-blade and Phillips screwdriver can also be used for time setting. Pin configuration compatible with MY Power Relay. LED indication for power and output statuses. Conforms to EMC standards. Conforms to EN61812-1 and approved by UL and CSA. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Ordering Information Operation/ Time-limit contact Time ranges Supply voltage Mounting resetting system Surface/DIN-track Surface mounting mounting (with PCB terminals) (with socket) Time-limit operation/ DPDT (for power 0.04 s to 3 h 24, 100 to 120, 200 to 230, 240 H3Y-2 H3Y-2-0 self-resetting switching) VAC (50/60 Hz) 12, 24, 48, 125, 100 to 4PDT H3Y-4 (See note 3.) H3Y-4-0 (See note 3.) 110 VDC Note: 1. Specify both the model number, supply voltage, and rated time when ordering. Ex. H3Y-2 100 to 120 VAC 0.5 s Rated time Supply voltage 2. Sockets and Hold-down Clips are not included with the H3Y. They must be ordered separately. 3. Use the H3Y-4 or H3Y-4-0 Series when switching micro loads. Accessories (Order Separately) Adapter, Mounting Plate, Clip Socket Name/specification Model Timer Square Sockets Connection Terminal Model Flush mounting adapter Y92F-78 Contact Model Pin Mounting For 1 Socket PYP-1 DIN track PYF08A Plate for mounting For 18 Socket PYP-18 Sockets DIN track Front mounting Clip For PYF AY92H-3 PYF08A-E Connecting (Finger- H3Y-2 For PY and DPDT 8-pin Y92H-4 safe tyape) H3YN-2 PYF M Screw PYF08F mounting Note: For details, refer to Safety Precautions. Back Solder PY08 Connecting terminal DIN track PYF14A mounting Front DIN track Connecting H3Y-4 mounting 4PDT 14-pin PYF14A-E H3YN-4 (Finger- safe tyape) Back Solder PY14 Connecting terminal Note: 1. Cannot be used with the H3Y- -0 (PCB terminals). 2. The PYF A-E has a finger-protection structure. Round crimp terminals cannot be used. Use forked crimp terminals. 3. For details, refer to Socket and DIN Track Products. 1H3Y Specifications Time Ranges Rated time Time setting range Rated time Time setting range 0.5 s 0.04 to 0.5 s 3 min 0.1 to 3 min 1 s 0.1 to 1 s 5 min 0.2 to 5 min 5 s 0.2 to 5 s 10 min 0.5 to 10 min 10 s 0.5 to 10 s 30 min 1 to 30 min 30 s 1.0 to 30 s 60 min 2 to 60 min 60 s 2.0 to 60 s 3 h 0.1 to 3 h 120 s 5.0 to 120 s --- --- Ratings Item H3Y-2(-0)/H3Y-4(-0) Rated supply voltage (See note 6, 7.) 100 to 120 (50/60 Hz), 200 to 230 VAC (50/60 Hz), 240 VAC (50/60 Hz), 24 VAC (50/60 Hz) (See note 1.), 12, 24, 48, 125, 100 to 110 VDC (See notes 2 and 3.) Operating voltage range All rated voltages except 12 VDC: 85% to 110% of rated supply voltage 12 VDC: 90% to 110% of rated supply voltage (See note 4.) Reset voltage 10% min. of rated supply voltage (See note 5.) Power consumption 100 to 120 VAC: 1.5 VA (at 120 VAC) 200 to 230 VAC: 1.8 VA (at 230 VAC) 240 VAC: 1.7 VA (at 240 VAC) 24 VAC: 1.5 VA (at 24 VAC) 12 VDC: 0.9 W (at 12 VDC) 24 VDC: 0.9 W (at 24 VDC) 48 VDC: 1.0 W (at 48 VDC) 100 to 110 VDC: 1.3 W (at 110 VDC) 125 VDC: 1.3 W (at 125 VDC) Control outputs H3Y-2(-0): 5 A at 250 VAC, resistive load (cos = 1) The minimum applicable load is 1 mA at 5 VDC (P reference value). Contact materials : Ag H3Y-4(-0): 3 A at 250 VAC, resistive load (cos = 1) The minimum applicable load is 1 mA at 1 VDC (P reference value). Contact materials : Au-clad + Ag-alloy Note: 1. Do not use the output from an inverter as the power supply. Refer to Safety Precautions for All Times for details. 2. With DC ratings, single-phase full-wave rectified power sources may be used. 3. Only the H3Y-2 and H3Y-2-0 Series include 2-VDC models. 4. Use the Timer within 90% to 110% of the rated supply voltage (95% to 110% for 12 VDC) when using it continuously under an ambient operating temperature of 50C. 5. Set the reset voltage as follows to ensure proper resetting. 100 to 120 VAC:10 VAC max. 200 to 230 VAC:20 VAC max. 100 to 110 VDC:10 VDC max. 6. Refer to Safety Precautions for All Times when combining the Timer with an AC 2-wire proximity sensor. 7. A diode to prevent reverse voltages is provided only on models with a DC power supply. 2

Tariff Desc

8536.69.10 62 Plugs and sockets for co-axial cables or printed circuits Free

8536.69.90 CONNECTORS, ELECTRICAL, being ANY of the following:
(a) plugs;
(b) sockets;
(c) adaptors
TC 1225594

8535.29.00 Other ELECTRICAL APPARATUS FOR SWITCHING OR PROTECTING ELECTRICAL CIRCUITS, OR FOR MAKING CONNECTIONS TO OR IN ELECTRICAL CIRCUITS (FOR EXAMPLE, SWITCHES, FUSES, LIGHTNING ARRESTERS, VOLTAGE LIMITERS, SURGE SUPPRESSORS, PLUGS AND OTHER CONNECTORS, JUNCTION BOXES), FOR A VOLTAGE EXCEEDING 1 000 VOLTS:

7415 Nails, tacks, drawing pins, staples (other than those of 8305) and similar articles, of copper or of iron or steel with heads of copper; screws, bolts, nuts, screw hooks, rivets, cotters, cotter-pins, washers (including spring washers) and similar articles, of copper:
7415.39.00 Other
OM4
OMRON
Omron Automation
Omron Automation & Safety
Omron Automation and Safety
OMRON AUTOMATION CANADA
OMRON ELECTRONIC COM
OMRON ELECTRONIC COMPONENTS
OMRON ELECTRONICS
Omron Electronics In
Omron Electronics Inc-EMC Div
Omron Electronics Inc-IA Div
OMRON INDUSTRIAL
OMRON INDUSTRIAL AUTOMATION
Omron Industrial Products
OMRON OCB
OMRON SAFETY
OMRON STI

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted