Product Information

G9SA-301 AC/DC24

G9SA-301 AC/DC24 electronic component of Omron

Datasheet
Safety Relays 24AC/DC 3PST-NO MAIN EMERGENCY STOP

Manufacturer: Omron
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (AUD)

1: AUD 539.175 ( AUD 593.09 Inc GST) ea
Line Total: AUD 539.175 ( AUD 593.09 Inc GST)

384 - Global Stock
Ships to you between
Fri. 19 Jul to Tue. 23 Jul
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
323 - Global Stock


Ships to you between Fri. 19 Jul to Tue. 23 Jul

MOQ : 1
Multiples : 1
1 : AUD 481.4952
10 : AUD 454.3915

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Contact Form
Contact Termination
Coil Voltage
Relay Contact Form
Series
Brand
Coil Power Rating
Coil Resistance
Factory Pack Quantity :
Cnhts
Hts Code
Product Type
Subcategory
Taric
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.

Safety monitoring relays G9SA g9SA Safety relay Unit Four kinds of 45-mm wide units are available: A 3-pole model, a 5-pole model, and models with 3 poles and 2 OFF-delay poles, as well as a two-hand controller. Also available are 17.5 mm wide expansion units with 3 poles and 3 OFF-delay poles. Simple expansion connection OFF-delay models have 15-step OFF-delay settings Conforms to EN standards (BG approval) Both DIN track mounting and screw mounting are possible Specifications ratings Power input i g9SA-301/th301 g9SA-501 g9SA-321-t Power supply voltage 24 VAC/VDC:24 VAC, 50/60 Hz, or 24 VDC 100 to 240 VAC:100 to 240 VAC, 50/60 Hz Operating voltage range 85% to 110% of rated power supply voltage Power consumption * 24 VAC/VDC: 1.8 VA/ 24 VAC/VDC: 2.8 VA/ 24 VAC/VDC: 3.5 VA/ 1.7 W max. 2.6 W max. 3.3 W max. 100 to 240 VAC: 100 to 240 VAC: 100 to 240 VAC: 9 VA max. 11 VA max. 12.5 VA max. *When an Expansion Unit is connected, the power consumption is increased by 2 VA/2 W max. inputs g9SA-301/321-t /th301 g9SA-501 Input current * 40 mA max. 60 mA max. * When an Expansion Unit is connected, the input current is increased by 30 mA max. contacts g9SA-301/501/321-t /th301/eX301/eX031-t resistive load Rated load 250 VAC, 5 A 30 VDC, 5 A Rated carry current 5 A Omr On Scientific technOlOgieS, inc. For the Latest Information i5 USA Tel. 1/888/510-4357 canada Tel. 1/866/986-6766 On the Internet: www.sti.comg9SA Safety monitoring relays Specifications (continued) characteristics g9SA-301/th301 g9SA-501/321-t g9SA-eX301/eX031-t Contact resistance *1 100 mW Operating time *2 30 ms max. Response time *3 10 ms max. Insulation resistance *4 100 M min. (at 500 VDC) Dielectric Between different outputs strength Between inputs and outputs 2,500 VAC, 50/60 Hz for 1 min Between power inputs and outputs Between power inputs and other inputs (only for 100 to 240-V models) Vibration resistance 10 to 55 to 10 Hz, 0.375 mm single amplitude (0.75 mm double amplitude) 2 Shock Destruction 300 m/s 2 resistance Malfunction 100 m/s Durability *5 Mechanical 5,000,000 operations min. (at approx. 7,200 operations/hr) Electrical 100,000 operations min. (at approx. 1,800 operations/hr) Failure rate (P Level) (reference value) 5 VDC, 1 mA Ambient operating temperature -25 to 55C (with no icing or condensation) Ambient operating humidity 35% to 85% Terminal tightening torque 0.98 Nm Weight *6 Approx. 210 g Approx. 270 g Approx. 130 g *1. The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method. *2. Not including bounce time. *3. The response time is the time it takes for the main contact to open after the input is turned OFF. Includes bounce time. *4. The insulation resistance was measured with 500 VDC at the same places that the dielectric strength was checked. *5. The durability is for an ambient temperature of 15 to 35C and an ambient humidity of 25% to 75%. *6. Weight shown is for 24-VAC/VDC type. For 100 to 240 VAC type, add approximately 20 g. i Applications g9SA-th301 (24 VDc) with 2-hand inputs Timing Chart S11 (NC) S11 (NO) S12 (NC) Feedback loop S12 (NO) KM1 and KM2 (NC) KM1 and KM2 (NO) 0.5 s max. Input time difference operates only when the difference is 0.5 s max. TH SA S11, S12: Two-hand pushbutton switches KM1 and KM2: Magnetic Contactor Control circuit Note: 1. Use a 1NC+1NO switch for S11 and S12. 2. This circuit achieves Safety Category 4. C D Omr On Scientific technOlOgieS, inc. For the Latest Information i6 USA Tel. 1/888/510-4357 canada Tel. 1/866/986-6766 On the Internet: www.sti.com

Tariff Desc

8536.49.00 TC 17103979 RELAYS, PRINTED CIRCUIT BOARD

8536.41 TC 8909066 RELAYS, having a continuous contact rating of NOT less than 3A and body dimensions NOT exceeding 40mm x 30mm x 27mm

8536.49.00 TC 9613322 RELAYS, low profile, OTHER THAN reed relays, being EITHER of the following:
(a) height NOT exceeding 21.24 mm;
(b) height NOT exceeding 35 mm and having a continuous current rating NOT less than 8A AC

8536.49 TC 8906734 RELAYS, having ALL of the following:
(a) one, two or three contacts;
(b) maximum continuous contact current rating of NOT less than 15A;
(c) maximum contact voltage rating of NOT less than 380V;
(d) maximum switched power rating of NOT less than 4000VA

8536.49.00 TC 1122469 RELAYS, having an operating voltage NOT exceeding 250 volts, having ANY of the following:
(a) spring loaded terminals
(b) plug-in screw terminals
(c) wire connected terminals

8536.41 TC 8534635 RELAYS, cradle, having ALL of the following:
(a) maximum switching current NOT exceeding 5 A (AC or DC);
(b) switching voltage NOT exceeding 250 V (AC or DC);
(c) body dimensions NOT exceeding 31 mm x 36 mm x 19 mm

8536.49 TC 8633667 RELAYS, vacuum, hermetically sealed

8536.41.00 TC 19144923 RELAYS, SWITCH AMPLIFIER, having a supply voltage NOT greater than 40v

8536.49 8633669 RELAYS, thermal overload, having ALL of the following characteristics:
(a) trip time NOT exceeding 5 s at 6 times full load current
(b) manual reset
(c) maximum current 50A

8536.49 TC 8633636 RELAYS, power appliance, 15A, having EITHER 2 contacts or 3 contacts

8536.41 TC 8438513 RELAYS, mercury wetted, contact type

8536.41 TC 8438500 RELAYS, coaxial
OM4
OMRON
Omron Automation
Omron Automation & Safety
Omron Automation and Safety
OMRON AUTOMATION CANADA
OMRON ELECTRONIC COM
OMRON ELECTRONIC COMPONENTS
OMRON ELECTRONICS
Omron Electronics In
Omron Electronics Inc-EMC Div
Omron Electronics Inc-IA Div
OMRON INDUSTRIAL
OMRON INDUSTRIAL AUTOMATION
Omron Industrial Products
OMRON OCB
OMRON SAFETY
OMRON STI

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted