Product Information

CTU-D5N

CTU-D5N electronic component of Netronix

Datasheet
RFID reader; antenna; 79.5x79.5x12mm; 5V; Card memory:40

Manufacturer: Netronix
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (AUD)

1: AUD 49.0905 ( AUD 54 Inc GST) ea
Line Total: AUD 49.0905 ( AUD 54 Inc GST)

610 - Global Stock
Ships to you between
Fri. 12 Jul to Thu. 18 Jul
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
582 - Global Stock


Ships to you between Fri. 12 Jul to Thu. 18 Jul

MOQ : 1
Multiples : 1

Stock Image

CTU-D5N
Netronix

1 : AUD 47.2
2 : AUD 44.64
25 : AUD 43.3
100 : AUD 42.92

     
Manufacturer
Product Category
Dimensions
Kind Of Transponder
Interface
Communications Modules Features
Type Of Communications Module
Card Memory
Supply Voltage
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.

Technical Data Sheet RFID reader CTU-D series CTU-Dxx-man-eng-v3.pdf Fig. 1 CTU-D2R ATTENTION THIS CONFIDENTIAL DOCUMENT IS PROPERTY OF NETRONIX SP. Z O.O. DISTRIBUTION OF THIS DOCUMENT IN ANY WAY WITHOUT SPECIAL PERMISSION OF ITS OWNER IS STRICTLY FORBIDDEN 1. INTRODUCTION ............................................................................................. 4 2. GENERAL SPECIFICATION........................................................................... 5 3. DIMENSION, TERMINAL DESCRIPTION....................................................... 6 4. MODULE SETTINGS BY ON-BOARD SWITCH............................................. 7 5. TRANSMISSION PROTOCOLS...................................................................... 7 5.1. RS-232/485 TRANSMISSION PROTOCOL ................................................ 7 2 5.2. Protocol for I C transmission............................................................................. 7 5.2.1. Data exchange algorithm ............................................................................... 7 5.2.2. Timings.............................................................................................................. 9 5.3. Protocol for 1WIRE (Dallas) bus...................................................................... 10 5.4. Wiegand protocol ................................................................................................ 11 6. COMMUNICATION PROTOCOL COMMANDS............................................ 11 6.1. Commands for communication with transponders ................................... 11 6.1.1. Selecting the transponder type.................................................................... 12 6.1.2. On/off switching of reader field.................................................................... 12 6.1.3. Reading the ID card unique number .......................................................... 12 6.2. Commands for communication with Q5 transponders............................. 13 6.2.1. Writing the ID-Unique number to Q5 transponder.................................... 13 6.2.2. Reading the sector of Q5 transponder....................................................... 13 6.2.3. Writing the sector of Q5 transponder ......................................................... 14 6.3. Commands for communication with HITAG transponders...................... 14 6.3.1. Reading the page of HITAG transponder.................................................. 14 6.3.2. Writing the page to HITAG transponder..................................................... 15 6.4. Reader inputs and outputs ............................................................................... 15 6.4.1. Writing the output state................................................................................. 15 6.4.2. Reading the input state................................................................................. 15 6.4.3. Writing the settings to any port.................................................................... 16 6.4.4. Reading-out the configuration of freely selected port .............................. 18 6.5. Access password ................................................................................................ 19 6.5.1. Logging to reader........................................................................................... 19 6.5.2. Changing the password................................................................................ 19 6.5.3. Logging out of the reader ............................................................................. 20

Tariff Desc

8542.3 - Electronic integrated circuits:
8542.31.00 -- Processors and controllers, whether or not combined with memories, converters, logic circuits, amplifiers, clock and timing circuits, or other circuits
Monolithic integrated circuits:
.Digital:
61 No ..Linear/analogue and peripheral integrated circuits, timers, voltage regulators, A/D and D/A converters, telecommunication and modem integrated circuits, other than board level products
62 No ..Other
63 No Hybrid integrated circuits
64 No Multichip integrated circuits

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted