Product Information

NMUSB202MC-R13

NMUSB202MC-R13 electronic component of Murata

Datasheet
Interface Modules Powered Dual Port USB Data Isolator

Manufacturer: Murata
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (AUD)
N/A

Obsolete
Availability Price Quantity
0 - Global Stock

MOQ : 92
Multiples : 92
92 : AUD 65.1875
184 : AUD 64.5833
276 : AUD 63.9792
460 : AUD 63.375
1012 : AUD 62.7708
1380 : AUD 62.1667
2300 : AUD 61.5625
4600 : AUD 60.9583
6900 : AUD 60.3542
N/A

Obsolete
0 - Global Stock

MOQ : 92
Multiples : 92
92 : AUD 67.1875
184 : AUD 63.8125
276 : AUD 59.7084
N/A

Obsolete
     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Series
Product
Type
Number of Channels / Ports
Maximum Data Rate
Operating Supply Voltage
Minimum Operating Temperature
Maximum Operating Temperature
Interface Type
Description/Function
Packaging
Dimensions
Operating Supply Current
Brand
Cnhts
Hts Code
Product Type
Factory Pack Quantity :
Subcategory
Taric
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.

NMUSB202MC www.murata-ps.com Powered Dual Port USB Data Isolator System NMUSB202MC Isolated Power LDO Linear voltage DC-DC Regulator rail/ Converter External adapter USB 2.0 Isolated USB USB Power Device Port 1 Switch FEATURES USB Data Data Full Speed Port from USB Hub USB Isolator n Isolated dual powered USB 2.0 compliant PC/USB Isolated USB Controller USB 2.0 Host Port 2 n Surface mount module Device n One upstream port, two isolated dowstream ports Isolation n Automatic switching between low (1.5Mbps) and full speed (12Mbps) SELECTION GUIDE n Full 500mA available from isolated ports 1 Order Code NMUSB202MC n 3kVAC Isolation Voltage Hi Pot Test n UL60950 recognized PRODUCT OVERVIEW n ANSI/AAMI ES60601-1 1MOPP/2MOOPs The NMUSB202MC is a surface mount module which conveniently provides dual port USB data isolation recognized from a single upstream port with full power (500mA) available from each downstream port. Isolation n Industrial temperature range -40C to provides effective breaking of ground loops and immunity to EMI in harsh environments as found in +85C industrial and medical applications. Full speed (12Mbps) and low speed (1.5Mbps) are supported with automatic switching. Input power of 5V is provided by an external adapter or system voltage rail. n Short Circuit/overload protected USB ports n Power surge notification n Patents Pending n 3D Model available 1. Components are supplied in tape and reel packaging, please refer to package specification section. Orderable part numbers are NMUSB202MC-R7 (23 pieces per reel), or NMUSB202MC-R13 (92 pieces per reel). For full details go to All specifications typical at TA=25C, nominal input voltage and rated output current unless otherwise specified. www.murata-ps.com/rohs www.murata-ps.com/support KDC NMUSB202MC.C01 Page 1 of 8NMUSB202MC Powered Dual Port USB Data Isolator DC-DC CHARACTERISTICS INPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Voltage range Continuous operation 4.5 5 5.5 V Current (hub inactive) 5V input 70 mA Current (hub active) 0% load 5V input 110 mA Current 100% load 5V input 1.3 A Input reflected ripple current 5V input 31 mA(rms) OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Downstream voltages 5V output 4.75 5 5.25 V Peak deviation (0-50-0% & 50-100-50% swing) -5 +3 %V out Transient response Settling time 40 400 s MODULE CHARACTERISTICS TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Operation See derating curve -40 85 Storage -50 105 C Product temperature rise above ambient 100% Load, Nom VIN, Still Air (measured on tranformer core) 31 37 ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Isolation test voltage Flash tested for 1 second 3000 VAC Resistance Viso = 1kVDC 20 G GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Leakage current 250 VAC 50Hz 1.31 1.35 A Common mode transient immunity 25 kV/ s ESD rating Rated on model 2000 V Calculated using MIL-HDBK-217 FN2 calculation model with nominal input 600 kHrs voltage at full load, 25C ambient temperature MTTF Calculated using Telecordia SR-332 calculation model with nominal input 3300 kHrs voltage at full load, 25C ambient temperature ABSOLUTE MAXIMUM RATINGS Parameter Conditions Value Short-circuit protection Downstream USB 5V Continuous Input voltage Upstream USB 5V supply 5.5V www.murata-ps.com/support KDC NMUSB202MC.C01 Page 2 of 8

Tariff Desc

8517.62.00 51 No Modems, of a type using digital to analogue modulation and analogue to digital demodulation, being goods of a kind having operational transmission speeds of 300 bits/second or greater
IPDiA
MU2
MUP
MUR
MURATA
Murata - TOKO
Murata / IPDiA
Murata Electronics
Murata Electronics N
Murata Electronics North America
MURATA MANUFACTURING
Murata Manufacturing Co.
Murata Power Solutio
Murata Power Solutions
Murata Power Solutions Inc
Murata Power Solutions Inc.
Toko
TOKO AMERICA
Toko America Inc.
TOKO, Inc.
TOKYO PARTS INDUSTRIAL
Tokyo Parts Industrial Group

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted