Product Information

MPS-TERM-03

MPS-TERM-03 electronic component of Littelfuse

Datasheet
Relay Sockets & Hardware TERM BLOCK SET CTU-03

Manufacturer: Littelfuse
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (AUD)
N/A

Obsolete
Availability Price Quantity
0 - Global Stock

MOQ : 1
Multiples : 1

Stock Image

MPS-TERM-03
Littelfuse

1 : AUD 409.3
5 : AUD 396.48
10 : AUD 394.54
25 : AUD 375.78
50 : AUD 375.78
100 : AUD 375.78
250 : AUD 370.02
N/A

Obsolete
     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Product
Accessory Type
Associated Relay Series
Packaging
Brand
Product Type
Factory Pack Quantity :
Subcategory
Cnhts
Hts Code
Taric
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.

Protection Relays and Controls Motor ProtectionAdvanced MPS SERIES (PGR-6300) Motor Protection System Description The MPS Motor Protection System monitors voltage, current, and temperature to provide a comprehensive package of PHASE CT GF CT 22 protective functions. The MPS is a modular system with PHASE CT integrated protection, motor control, metering, and data-logging M PHASE CT functions. This system is typically used to provide protection for RTD x 8 three-phase low- and medium-voltage, medium- to high-horsepower induction motors. 1 MPU-CIM MPS-RTD Operator Interface (MPS-OPI) (Current Input Module) (Temperature 1 Input Module) g Large, bright, 4 x 20 vacuum-fluorescent display g Display metered values g MPU-32 Access set points (Motor Protection Relay) g L1 Powered by Control Unit g L2 Panel mount or attach directly to Control Unit g Remote mounting (1.2 km or 4000 ft maximum loop length) g 1/2 DIN size g Hazardous-location certified Control Unit (MPS-CTU) 2 g 2 Current inputs5-A or 1-A secondary phase current transformers g Voltage inputsup to 600 V without PTs g Earth-leakage input5-A or 1-A secondary or sensitive transformer Simplified Circuit Diagram g Tachometer (high-speed pulse) input g PHASE CT GF CT 8 digital inputs, 5 relay outputs, 1 analog input and output A B g 24-Vdc supply for OPI and RTD modules, and for digital inputs PHASE CT g IRIG-B time-code input M PHASE CT g 1/2 DIN size, surface mount RTD x 8 g RS-485 network communications (Standard) g DeviceNet , Profibus , or Ethernet communications available MPS-RTD (Temperature MPS-CTU Input Module) L1 (Control Unit) C 2 L2 Accessories MPS-OPI A Phase Current Transformers 1 (Operator Interface) Phase CTs are required to detect phase currents. Ordering Information Ground-Fault Current Transformer ORDERING NUMBER COMMUNICATIONS B Required zero-sequence current transformer MPS-CTU-01-00 RS-485 detects ground-fault current. Available with 5-A MPS-CTU-02-00 RS-485 & DeviceNet and 30-A primary ratings for low-level pickup. MPS-CTU-03-00 RS-485 & Profibus MPS-CTU-04-00 RS-485 & EtherNet/IP & Modbus TCP C MPS-RTD Temperature Input Module Optional module provides 8 inputs to connect ACCESSORIES REQUIREMENT Pt100, Ni100, Ni120, and Cu10 RTDs. MPS-OPI-01-00 Recommended D Phase CTs Required MPS-DIF Differential Current Module Optional motor differential protection, Ground-Fault CT Recommended compatible with core balance and summation MPS-RTD-01-00 Optional current transformer connections. MPS-DIF-01-00 Optional SE-IP65CVR-M Optional 2017 Littelfuse Protection Relays & Controls Rev: 4-B-061517 Littelfuse.com/mps Based on Manual Rev: 6-F-022117Protection Relays and Controls Motor ProtectionAdvanced MPS SERIES (PGR-6300) Motor Protection System Features & Benefits FEATURES IEEE BENEFITS Overload 49, 51 Extends motor life and prevents insulation failures and fires Current unbalance/ 46 Prevents overheating and extends motor life Phase loss/Phase reverse Overcurrent/Jam 50, 51 Prevents catastrophic failures and fires and extends motor life Undercurrent 37 Detects low-level or no-load conditions Ground fault 50G/N, 51G/N Prevents catastrophic failures and fires Optional RTD temperature protection (MPS-RTD module) for RTD temperature 38, 49 high ambient or loss of ventilation protection Overvoltage 59 Prevents stress to insulation Undervoltage 27 Prevents a start attempt when it will damage the motor Voltage unbalance 47 Detects unhealthy supply voltage Phase differential 87 Provides sensitive protection for high-resistance winding faults Dynamic thermal mode Provides protection through starting, running, overload, and cooling cycles Reduced overcurrent mode Minimizes Arc-Flash hazards during maintenance Starter control Simplifies the installation by reducing component count Metering Displays the measured and calculated motor parameters Data logging On-board 64-event recorder helps with system diagnosis Communications Remotely view measured values, event records & reset trips Conformal coating Internal circuits are conformally coated to protect against corrosion and moisture Wiring Diagram MPS-OPI Specifications OPERATOR INTERFACE Protective Functions Overload (49, 51) RTD temperature (38, 49) (recommended) (IEEE Device Numbers) Phase reverse (current) (46) Unbalance (current) (46) 1 Overfrequency (81) Underspeed (14) Overcurrent (50, 51) Starts per hour (66) GROUND-FAULT Jam Phase loss (voltage) (47) PHASE CURRENT MPS-RTD TRANFORMERS CURRENT Underfrequency (81) Overvoltage (59) RTD MODULE TRANSFORMER Ground fault (50G/N, Differential (87) (required) (optional) (required) 51G/N) Phase loss (current) (46) C A B Undercurrent (37) Undervoltage (27) Unbalance (voltage) (47) Phase reverse (voltage) (47) MPS-DIF DIFFERENTIAL Failure to accelerate Power factor (55) MODULE PHASE Input Voltage 65-265 Vac, 25 VA 80-275 Vdc, 25 W (optional) VOLTAGES Power-Up Time 800 ms at 120 Vac D Ride-Through Time 100 ms minimum 24-Vdc Source 100 mA maximum AC Measurements True RMS and DFT, Peak, 16 samples/cycle, and 33 22 30 29 27 26 23 22 20 17 60 56 53 52 ...... positive and negative sequence of fundamental + I/0 MODULE 4-20 mA Frequency 50, 60 Hz or ASD ANALOG Inputs Phase current, Earth-leakage current, Phase voltage, INPUT MPS-CTU 7 digital, tachometer, 1 analog CONTROL UNIT Output Contacts 5 contacts See Product Manual Approvals CSA Certified, RCM ( Australian), UL Recognized Communications Allen-Bradley DFI and Modbus RTU (Standard) DeviceNet, Profibus , Ethernet (Optional) ANALOG OUTPUT Conformally Coated Standard feature DIGITAL RELAY RS-485 4-20 mA OUTPUTS INPUTS + Warrant y 10 years 1 2 5 16 35 37 39 40 43 51 2 .............. Mounting (Control Unit) Surface (Operator Interface) Panel, Control-Unit mounted CONTROL POWER 2017 Littelfuse Protection Relays & Controls Rev: 4-B-061517 Littelfuse.com/mps Based on Manual Rev: 6-F-022117

Tariff Desc

8536.69.10 62 Plugs and sockets for co-axial cables or printed circuits Free

8536.69.90 CONNECTORS, ELECTRICAL, being ANY of the following:
(a) plugs;
(b) sockets;
(c) adaptors
TC 1225594

8535.29.00 Other ELECTRICAL APPARATUS FOR SWITCHING OR PROTECTING ELECTRICAL CIRCUITS, OR FOR MAKING CONNECTIONS TO OR IN ELECTRICAL CIRCUITS (FOR EXAMPLE, SWITCHES, FUSES, LIGHTNING ARRESTERS, VOLTAGE LIMITERS, SURGE SUPPRESSORS, PLUGS AND OTHER CONNECTORS, JUNCTION BOXES), FOR A VOLTAGE EXCEEDING 1 000 VOLTS:

7415 Nails, tacks, drawing pins, staples (other than those of 8305) and similar articles, of copper or of iron or steel with heads of copper; screws, bolts, nuts, screw hooks, rivets, cotters, cotter-pins, washers (including spring washers) and similar articles, of copper:
7415.39.00 Other
C&K Aerospace
HAMLIN
Hamlin Littelfuse
Hamlin / Littelfuse
Hamlin Inc
Hartland Controls / Littelfuse
LF
LF7
Littelfuse Teccor Sidactor Product
Littelfuse Wickmann Brand
Littelfuse / US Sensor
Littelfuse Inc
Littelfuse Inc.
LITTELFUSE SEMITRON
LITTELFUSE WICKMANN
LITTELFUSE, INC.
Little Fuse / Wickmann
Littlefuse
SSAC
SSAC Relays
TE Connectivity / Circuit Protection
WICKMANN USA

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted