Product Information

ISS-105

ISS-105 electronic component of Littelfuse

Datasheet
Controllers 5-CHINTRINSICALLY-SA FESWITCH

Manufacturer: Littelfuse
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (AUD)

1: AUD 995.463 ( AUD 1095.01 Inc GST) ea
Line Total: AUD 995.463 ( AUD 1095.01 Inc GST)

1 - Global Stock
Ships to you between
Fri. 26 Jul to Tue. 30 Jul
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
1 - Global Stock


Ships to you between Fri. 26 Jul to Tue. 30 Jul

MOQ : 1
Multiples : 1

Stock Image

ISS-105
Littelfuse

1 : AUD 995.463
10 : AUD 984.1868

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Number of Inputs
Number of Outputs
Series
Analog / Digital
Display Type
Packaging
Type
Brand
Maximum Operating Temperature
Minimum Operating Temperature
Operating Supply Voltage
Product Type
Factory Pack Quantity :
Subcategory
Cnhts
Hts Code
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.

Protection Relays Intrinsically Safe Relays ISS-105 SERIES Five-Channel Intrinsically Safe Switch Description The ISS-105 is a smart five-channel intrinsically safe relay and pump controller. The ISS-105 can be configured for pump-up or pump-down applications or as a five-channel relay covering a wide variety of applications. The ISS-105 has a long list of features that are needed for multiple pump applications and can indicate low, high and out-of-sequence alarms. If an out-of-sequence alarm occurs, the skipped pump(s) will be started as intended. The Model ISS-105 can be set-up to do non-alternating control, alternating control and alternating control with one non-alternating pump. The non-alternating pump is intended for use with an emergency or jockey pump. The ISS-105 can start an emergency pump once every 50 cycles to keep it working freely. Using the built-in DIP switches, individual pumps can be disabled when taken out of service for repair or maintenance. Features & Benefits Wiring Diagram JJ 5 intrinsically-safe input channels meeting UL913 Sixth Edition Typical Application: TYPICAL APPLICATION: JJ 4 normally open output relays and 1 SPDT output relay Audible Alarm Duplex Pump-Down with High and Low AlarmsDuplex Pump Down with High and Low Alarms. High JJ Alarm Field selectable pump control options JJ Monitors float sequencing and sends signal to alarm if Low Alarm out-of-sequence condition occurs 120 VAC JJ High and/or low alarm options depending on the number of Pump Pump 1 2 pumps and settings JJ Output contacts for audible alarm High Alarm Float JJ Meets IEC EMC standards for Electrical Fast Transients (EFT), 1 2 3 4 5 INPUT Electrostatic Discharge (ESD) and Radio Frequency Immunity (RFI) Lag 1 Float 120 VAC JJ PUMP PUMP LOW HIGH AUDIBLE MODE 1 DIN rail or surface mountable allows flexibility in 1 2 ALARM ALARM ALARM DUPLEXER PUMP DOWN Lead Float IS Super Cell panel installation MODEL ISS-105 LOW HIGH ALARM OFF LEAD LAG1 ALARM COMMON JJ INTRINSICALLY Stop Float User-selectable alternator/non-alternator option SAFE INPUTS 1 2 3 4 5 C JJ Non-alternating pump option for emergency or Low Alarm Float jockey applications JJ Pump disable switches make it easy to disable individual pumps when they are out for service or repair Many other configurations are possible. See users manual for more details. PUMP JJ Adjustable lag pump delay for all pumping modes JJ Adjustable delay-on-make/break timer in five-channel relay mode JJ Finger-safe terminals meet IEC 61000 safety requirements Ordering Information MODEL LINE VOLTAGE DESCRIPTION ISS-105 120VAC Intrinsically-Safe & Pump Controller ISS-105-ISO 120VAC Intrinsically-Safe Only ISS-105-ISO-3 120VAC 3-Channel Intrinsically-Safe Only ISS-105-ISO-4 120VAC 4-Channel Intrinsically-Safe Only ISS-105-ISO-F 120VAC ISO with Fast Trip Relays 2017 Littelfuse Protection Relays & Controls Rev: 1-B-050517 wwwwww.littelfuse.com/.littelfuse.com/iss105Protection Relays Intrinsically Safe Relays ISS-105 Standards Passed Specifications Electrostatic Discharge (ESD) IEC 61000-4-2, Level 3, 6kV contact, 8kV air. Input Characteristics Radio Frequency Immunity (RFI) IEC 61000-4-3, Level 3, 10V/m Supply Voltage 120VAC Fast Transients IEC 61000-4-4, Level 3, 4kV input power Frequency 50*/60Hz 2kV inputs/outputs Functional Characteristics Safety Marks Probe Sense Voltage 5vdc continuous UL UL913 Sixth Edition (File E233355) Output Characteristics Dimensions H 94.06 mm (3.703) W 127.64 mm (5.025) Relay Output Rating D 59.69 mm (2.350) Pilot Duty 480VA 240VAC, B300 Weight 1.2 lbs. (19.2 oz., 544.31 g) General Purpose 7A 240VAC Mounting Method 35 mm DIN rail or Surface Mount Relay Contact Life (Electrical) 100,000 cycles min. rated load ( 6 or 8 screws) Relay Contact Life (Mechanical) 10,000,000 cycles General Characteristics Temperature Range -40 to 55C (-40 to 131F) *Note: 50Hz will increase all delay timers by 20%. Maximum Input Power 5 W Wire range 12 to 20 AWG Recommended Terminal Torque 3.5 to 4.5 in.-lbs. (max. 4.5 in.-lbs.) Provides Intrinsically-Safe Circuits in the following locations: Division 1 and 2 Class I, Groups A,B,C,D Class II, Groups E,F,G and Class III Entity Parameters V = 16.8V Po=Voc*Isc oc I = 1.2mA 4 sc L = 100mH a C = 0.39uF a 2017 Littelfuse Protection Relays & Controls Rev: 1-B-050517 wwwwwwwww.littelfuse.com/iss105.littelfuse.com/.littelfuse.com/

Tariff Desc

8473.30.00 - Parts and accessories of the machines of 8471 AUTOMATIC DATA PROCESSING MACHINES AND UNITS THEREOF; MAGNETIC OR OPTICAL READERS, MACHINES FOR TRANSCRIBING DATA ONTO DATA MEDIA IN CODED FORM AND MACHINES FOR PROCESSING SUCH DATA, NOT ELSEWHERE SPECIFIED OR INCLUDED: Free
62 No .Cards (including network, sound, video, IDE, SCSI, and other similar cards)
C&K Aerospace
HAMLIN
Hamlin Littelfuse
Hamlin / Littelfuse
Hamlin Inc
Hartland Controls / Littelfuse
LF
LF7
Littelfuse Teccor Sidactor Product
Littelfuse Wickmann Brand
Littelfuse / US Sensor
Littelfuse Inc
Littelfuse Inc.
LITTELFUSE SEMITRON
LITTELFUSE WICKMANN
LITTELFUSE, INC.
Little Fuse / Wickmann
Littlefuse
SSAC
SSAC Relays
TE Connectivity / Circuit Protection
WICKMANN USA

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted