Product Information

N2140A

N2140A electronic component of Keysight

Datasheet
Test Probes Probe,Passive 10X 200MHz, 2-Pack

Manufacturer: Keysight
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (AUD)

1: AUD 214.2 ( AUD 235.62 Inc GST) ea
Line Total: AUD 214.2 ( AUD 235.62 Inc GST)

37 - Global Stock
Ships to you between
Fri. 26 Jul to Tue. 30 Jul
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
74 - Global Stock


Ships to you between Fri. 26 Jul to Tue. 30 Jul

MOQ : 1
Multiples : 1

Stock Image

N2140A
Keysight

1 : AUD 204.3462

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Equipment Type
Type
Bandwidth
Length
Description/Function
Brand
Product Type
Factory Pack Quantity :
Subcategory
Tradename
Cnhts
Hts Code
Taric
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.

Safety and Regulatory Information The probe cable is a sensitive part of the probe Keysight N2140A and N2142A and, therefore, you should be careful not to damage it through excessive bending or pulling. CSA is the Canadian certification mark to Avoid any mechanical shocks to the product to demonstrate compliance with the Safety requirements. Passive Probes guarantee accurate performance and protection. Do not use the probe assembly if the red wear The CE mark is a registered trademark of the Quick Start Guide indicator in the cable has become visible. European Community. ISM GRP 1-A denotes the instrument is an Industrial Scientific and Medical Group 1 Class A product. ICES/NMB-001 Some of the probe tips / accessories are very indicates product compliance with the Canadian sharp. You should handle these with care to Interference-Causing Equipment Standard. avoid personal injury. This symbol indicates the Environmental Protection Use Period (EPUP) for the products toxic Use only Grounded instruments. Do not connect 2 the probes ground lead to a potential other than substances for the China RoHS requirements. 3 earth ground. Always make sure that the probe IEC Measurement category II is for measurements and oscilloscope are grounded properly. CAT II 1 performed on circuits directly connected to the low voltage installation. Example. Household 4 Connect the probe to the oscilloscope and appliances portable tools, and similar equipment. connect the ground lead to earth ground before connecting the probe to the circuit under test. 5 6 Disconnect the probe input and the probe ground lead from the circuit under test before 7 disconnecting the probe from the oscilloscope. Indoor Use Only. Do not operate in wet / damp environments. Keep product surfaces dry and clean. Do not operate in an explosive environment. Keysight Technologies 2017 If your probe requires cleaning, disconnect N2140-92001, June 2017, it from the instrument and clean it with Printed in USA mild detergent and water. Make sure the probe is completely dry before connecting it to the instrument. *N2140-92001*The Keysight N2140A 200 MHz and N2142A 75 MHz passive These probes have been designed and calibrated for use Table 2 - Electrical Characteristics probes are high impedance probes with switchable attenuation with instruments having an input impedance of 1M ratio (1:1 and 10:1). These are compatible with the Keysight paralleled by 20pF. However, these may be recalibrated for Value Characteristic InfiniiVision EDUX1002A/G and DSOX1102A/G digital storage use with instruments having an input capacitance of Attenuation Ratio 1:1 / 10:1 oscilloscopes or similar oscilloscopes with 1 Mohm BNC input. 15 to 30pF. Input Capacitance 1:1 - 100pf 10:1 - 15pf Adjusting Probes for Low-Frequency (LF) Compensation Compensation range The BNC connector of these probes has a 15pf - 30pf The probe should be adjusted for LF compensation when it is (when terminated pin hole without a pin. This is as per the into 1 Mohm) connected to an oscilloscope input for the first time. LF design and does not indicate any damage compensation matches the probe cable capacitance to the or fault in the probe. Input Resistance 1:1 - 1M 10:1 - 10M oscilloscope input capacitance. This matching assures good Pin hole amplitude accuracy from DC to the upper bandwidth limit Maximum Input 1:1 - 150V rms CAT II without frequencies. A poorly compensated probe clearly influences Voltage 10:1 - 300V rms CAT II BNC a pin the overall system performance (probe and oscilloscope) Connector Current Rating and introduces measurement errors resulting in inaccurate 0.15mA (DC, 1:1, & maximum voltage) readings and distorted waveforms. For optimal probe compensation: For N2142A For N2140A Bandwidth Table 1 - Probe and its Supplied Accessories - Allow the oscilloscope (with the probe connected) to warm 1:1 - 6 MHz 1:1 - 6 MHz up for at least 30 minutes. 10:1 - 75 MHz 10:1 - 200 MHz Quantity - Repeat the compensation steps if the ambient temperature ID Part in the area in which the oscilloscope is being used changes For N2140A For N2142A Table 3 - Physical & Environmental Characteristics by more than 5 degrees C. Passive probe 2 2 - Do NOT push down on the adjustment screw when engaging Value Characteristic or turning this screw. Ground Spring - 2 To perform LF compensation: Probe Body 95mm Ground Lead 2 2 1 Connect the probe to the oscilloscopes front-panel Cable Length 1200mm calibration output (a square wave label is usually seen near Adjustment Tool 1 1 this output). Weight 55g Hook Tip 2 2 2 Use the supplied adjustment tool to adjust the LF Temperature -10 C to +55 C (Operating) Protective Cap 1 1 compensation to an optimum square wave response as -40 C to +70 C (Non-operating) shown in the figure below. Channel 2 sets of each color with Altitude 3,000 m (9,842 ft) (Operating) Identification rings two rings in each set 12200 m (40,026 ft) (Non-operating) Humidity 5% to 95% RH up to 30 C (Operating) These accessories are provided in the N2141A kit for the 5% to 65% RH above 30 C up to 55 C N2140A probe and the N2143A kit for the N2142A probe. (Non-operating) Undercompensated Overcompensated Optimum

Tariff Desc

8536.90 PROBES, multimeter Op. 20.03.1984 Dec. 20.03.1984 - TC 8342739

8536.69.10 62 Plugs and sockets for co-axial cables or printed circuits Free

8536.69.90 CONNECTORS, ELECTRICAL, being ANY of the following:
(a) plugs;
(b) sockets;
(c) adaptors
TC 1225594

8536.69.90 SOCKETS, being ANY of the following:
(a) single pin, NOT exceeding 3.5 mm;
(b) micro, single pin, 2 mm;
(c) DC power connector, 2.1 mm OR 2.5 mm;
(d) 9 pin OR 15 pin, sub D;
(e) 2, 4 OR 8 pole microphone connector;
(f) 2, 3, 5, 6, 7, 8 OR 13 pin DIN;
(g) 16, 20, 26, 34, 40 OR 50 way dual in line crimp-on
TC 9900883

8536.69 JACKS, phono, RCA Type
TC 8438480

8536.69.90 CONNECTORS, electrical, incorporating twist locking mechanism
TC 9703905

8536.70.90 CONNECTORS, OPTICAL Op. 12.06.2007 FIBRE
TC 0708845

8536.90.90 LUGS, being solderable, copper connectors
TC 0613954

8535.90.00 CRIMPING TERMINALS, having bell-mouth OR flared cable entry
TC 9504891

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted