ETA-USA The Power Professionals 300W AC/DC Switching Adapter-Single Output DTMF300-SX-F-W6 FEATURES: ITE 62368-1 & Medical 60601-1 approvals. ( Class I ) 3-prong IEC320-C14, Class I (I/O Switch Option) - Fanless Medical safety approved ( 2x MOPP between primary to secondary ) Suitable for BF application with appropriate system consideration. Altitude during operation: ITE/Medical up to 5000m. 0.15W No Load Input Power Touch current less than 100uA Meet IEC60601-1-2 Ed4:2014 3 year warranty BAUART GEPRFT TUV Rheinland DTMF300- DTMF300- DTMF300- DTMF300- MODEL/CHANNEL Unit 12SX-F-W6 15SX-F-W6 19SX-F-W6 24SX-F-W6 OUTPUT Norminal Voltage V 12 15 19 24 Norminal Current A 25 20 15.79 12.5 Over Voltage Range Vdc 12.9-16 16-20 20.2-25.46 25.5-32.16 Ripple & Noise Max mV 240 300 DTMF300- DTMF300- DTMF300- MODEL/CHANNEL Unit 28SX-F-W6 48SX-F-W6 54SX-F-W6 Norminal Voltage V 28 48 54 OUTPUT Norminal Current A 6.25 6.25 5.56 Over Voltage Range Vdc 29.6-33.2 50-57.2 56-60.2 Ripple & Noise Max mV 300 Turn On/Turn Off % 5 OUTPUT Temperature Coefficient C 0.05% perC maximum. Output Regulation % 5 Output Power W 300 Temperature Coefficient C 0.05% perC maximum. INPUT Hold Up Time ms 10mS Typ. 115VAC Input Voltage Range V 90-264VAC Frequency A 47-63Hz Input Current (rms) A 3A 115 VAC/60Hz Power factor - >0.9 full load >88% (Average) 25%, 50%, Efciency % 75% and 100% of full load 115/230VAC Earth leakage current VAC < 250uA 264VAC Inrush current VAC 70A 230VAC Cold Start 25 ETA-USA 16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 ETA-USA The Power Professionals MODEL/CHANNEL Unit Protection Overvoltage Protection Vdc Auto Turn OFF Short Circuit Protection V Auto Recovery Over Load Protection % 105% to +150% Max Environmental RU CB IEC 60601-1 TUV 60601-1 TUV RH 62368-1 Safety Standards - Agencies CB 60950-1 PSE CCC FCC Part 18 Class B EN 55011 Class B EN55022 Class B EMC Standards - EN55024 Class B FCC Part 15 Class B CE 60950-1 CE 60601-1 ICES Environment Operating temp. & Humidity - 0 to +60C (Refer toDerating Curv) -30C to +60C (Derate linearly 2.5% per C from 41 to 60C) Temperature - (Derate linearly 1.0% per C from -1 to -30C) Storage temp. & Humidity - -30C to +85C 0 to 95%, non condescending Burn-in Test - 100% burn-in tested under 40 +/-5C. MTBF demonstrated H 200,000 hours min. max. load for 25C ambient temperature. Dielectric Primary-Secondary - 5656 VDC for 4 Sec. Withstand Secondary-Frame Ground - 2121 VDC for 4 Sec. Primary-Frame Ground - Primary to Frame Ground 2121 VDC for 4 Sec. Insulation Primary-Secondary - 20 MW Min. 500 VDC. Resistance Primary-Frame Ground - 20MW Min. 500 VDC. Dimension Size(WxHxD) / Weight mm/g 222LxW11245H/1.57 kgs. Derating Curve 300W - ETA-USA 16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037