Tin-plated 3 Max. 79 m /h DC axial fans 80 x 25 mm 1) Material: Housing: GRP (PBT) Possible special versions: 1) Impeller: GRP (PA) (See chapter DC fans - specials) Direction of air flow: Exhaust over struts - Speed signal Direction of rotation: Counterclockwise, - Go / NoGo alarm looking towards rotor - Alarm with speed limit Connection: Via single wires AWG 24, - External temperature sensor TR 64 - Internal temperature sensor Highlights: Some models are suitable for - PWM control input use at high ambient - Analog control input temperatures up to 85 C. - Moisture protection Weight: 95 g - Degree of protection: IP 54 / IP 68 1) Fiberglass-reinforced plastic Series 8400 N Nominal data 3 -1 Type m /h cfm VDC VDC dB(A) Bel(A) / Watts rpm C Hours Hours 8412 NGLE 33 19.4 12 8...15 12 3.5 0.5 1 500 -20...+85 80 000 / 27 500 135 000 8412 NLE 33 19.4 12 8...15 17 3.7 0.3 1 500 -20...+85 80 000 / 27 500 135 000 8412 NGMLE 45 26.5 12 8...15 19 3.9 0.9 2 050 -20...+80 80 000 / 32 500 135 000 8412 NMLE 45 26.5 12 8...15 21 4.0 0.6 2 050 -20...+85 80 000 / 27 500 135 000 8412 NGME 58 34.1 12 8...15 26 4.3 1.4 2 600 -20...+75 80 000 / 35 000 135 000 8412 NME 58 34.1 12 8...15 27 4.4 1.0 2 600 -20...+75 80 000 / 35 000 135 000 8412 NG 69 40.6 12 8...15 32 4.7 2.0 3 100 -20...+70 70 000 / 35 000 117 500 8412 N 69 40.6 12 8...15 32 4.7 1.7 3 100 -20...+70 70 000 / 35 000 117 500 8412 NH 79 46.5 12 8...13.2 37 5.0 2.1 3 600 -20...+70 70 000 / 35 000 117 500 8412 NH-217 79 46.5 12 8...15 37 5.0 2.5 3 600 -20...+70 70 000 / 35 000 117 500 8414 NGL 33 19.4 24 18...28 12 3.5 0.9 1 500 -20...+70 80 000 / 40 000 135 000 8414 NL 33 19.4 24 18...28 17 3.7 0.8 1 500 -20...+70 80 000 / 40 000 135 000 8414 NGML 45 26.5 24 18...28 19 3.9 1.2 2 050 -20...+70 80 000 / 40 000 135 000 8414 NML 45 26.5 24 18...28 21 4.0 1.1 2 050 -20...+70 80 000 / 40 000 135 000 8414 NGM 58 34.1 24 18...28 26 4.3 1.4 2 600 -20...+70 80 000 / 40 000 135 000 8414 NM 58 34.1 24 18...28 27 4.4 1.4 2 600 -20...+70 80 000 / 40 000 135 000 8414 NG 69 40.6 24 18...28 32 4.7 2.2 3 100 -20...+70 70 000 / 35 000 117 500 8414 N 69 40.6 24 18...28 32 4.7 1.8 3 100 -20...+70 70 000 / 35 000 117 500 8414 NH 79 46.5 24 18...26 37 5.0 2.4 3 600 -20...+70 70 000 / 35 000 117 500 8414 NH-221 79 46.5 24 18...28 37 5.0 2.2 3 600 -20...+70 70 000 / 35 000 117 500 8418 N 69 40.6 48 36...56 32 4.7 2.0 3 100 -20...+70 70 000 / 35 000 117 500 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level L A ISO 103002 W measured on a hemisphere with a radius of 2 m. Sound pressure level L A measured at 1 m distance p from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configura- tion, the parameters must be checked after installation For detailed information see