Product Information

CCP2-AUX-S

CCP2-AUX-S electronic component of Eaton

Datasheet
Circuit Breaker Accessories Eaton Corporation

Manufacturer: Eaton
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (AUD)

1: AUD 86.871 ( AUD 95.56 Inc GST) ea
Line Total: AUD 86.871 ( AUD 95.56 Inc GST)

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Global Stock


Ships to you between Fri. 26 Jul to Tue. 30 Jul

MOQ : 1
Multiples : 1
1 : AUD 111.9865
5 : AUD 107.5846
10 : AUD 99.4818
50 : AUD 85.1954
100 : AUD 79.5157
250 : AUD 78.624
500 : AUD 76.3366

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Brand
Subcategory
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.

Fuse and fuse block cross reference, and index 16 Contents Section Description page Fuse sizing for 600 V building electrical systems 2-3 Selective coordination 4 Low voltage, branch circuit fuse types and classes 5 We make what Glossary of common electrical terms 6-7 Electrical formulas 7 matters work * FuseFinder fuse and fuse block cross reference 8-9 Catalog number index 10-14 For information on products not contained in this catalog, contact Customer Satisfaction, toll-free, at 855-287-7626 (855-BUSSMANN) between 7:00 a.m. 6:00 p.m. Central time, M-F, or email Horseless carriages. World War BussCustSat Eaton.com. * II aircraft. NASA space shuttles. Electric vehicles. Over the past 100 years, Bussmann series products have protected the things that have propelled our world forward. And theyll continue to protect for the next 100 years. Because we never lose sight of what matters. And its our job to make sure it works. BUSSMANN SERIES FULL LINE CATALOG 1007 OCTOBER 2018 Eaton.com/bussmannseries 16-1 Cross reference and index16 Fuse and fuse block cross reference, and index 4. Feeder circuit with mixed loads. (430.63) Size fuse at sum of: Fuse sizing for 600 V building electrical systems a. 150% to 175% of the largest motors full-load current**, General guidelines are given for selecting fuse amp ratings for plus most circuits. For specific applications warranting other fuse sizing, b. 100% of all other motors full-load current**, plus the load characteristics and appropriate NEC sections should be considered. The selections shown here are not, in all cases, c. 125% of the continuous, non-motor load, plus the maximum or minimum amp ratings permitted by the NEC. d. 100% of the non-continuous, non-motor load Demand factors as permitted by the NEC are not included. Study the pertinent NEC sections noted by () and reference pertinent 5. Branch circuit with no motor load. (210.20) The fuse size footnotes. must be at least 125% of the continuous load plus 100% of the non-continuous load. Do not size larger than the conductors ampacity*. Recommended fuses: Low-Peak KRP-C Class L, time-delay, 601 to 6000 A 6. Motor branch circuit with overload relays. Where overload Low-Peak 250 V LPN-RK/600 V LPS-RK Class RK1, dual element, time-delay, up to 600 A relays are sized per 430.32 for motor running overload Fusetron 250 V FRN-R/600 V FRS-R Class RK5, protection, there are various alternatives: 1 dual element, time-delay, up to 600 A 6a. Motor branch circuit short-circuit and ground fault protection. (430.52) (most common). Size the fuse between 150 to 175% of the full load current.** Provides Feeder Feeder Feeder branch circuit short-circuit and ground fault protection only. Fuse with no with all with 10 8 2 3 4 11 > 600 A motor motor combo 6b. Motor branch circuit short-circuit and ground fault load load motor/ protection (430.52) as well as backup overload no motor Motor load protection. Size FRN-R and FRS-R Class RK5 dual-element, starter time-delay fuses at 125% and LPN-RK-SP and LPS-RK-SP overload relay Class RK1 dual-element, time-delay fuses at 130% of motor 6a 6b 7 12 full-load current or next higher size. This results in closer Large fuse sizing and provides some backup running overload M motor protection. In addition, it provides motor branch circuit short- circuit and ground fault protection. Sizing in this manner may result in better motor protection if the overload relays are not properly sized or calibrated. 5 5 5 M M M 7. Motor branch circuit with only fuse protection. Where the fuse is the only motor protection, the following FRS-R and FRN-R, Class RK5, fuses provide motor running overload protection (430.32) and short-circuit protection (430.52): Cont. Non- loads, cont. Motor 1.15 ser vice factor or 40C rise. Size the fuse at 110% lighting/ loads 7 5 7 7 5 to 125% of the motor full-load current on the name plate heating 430.6(a)(2) . Motor less than 1.15 ser vice factor or over 40C rise. Size M M M fuse at 100% to 115% of motor full-load current on the name 9 Continuous plate 430.6(a)(2) . loads Power factor 8. Large motor branch circuit. Fuse larger than 600 A. 436.52(c) correction and 430.52(c)(1) Exceptions 2(d) . For large motors, size Low- capacitor Peak KRP-C-SP time-delay fuse at 175% to 300% of the motor Dual-element, time-delay fuses full-load current**, depending on the starting method i.e., part- winding starting, reduced voltage starting, etc. Class CF (up to 400 A), and J, RK1 and RK5 ( up to 600 A) 9. Power factor correction capacitors. 460.8(b) . Size dual- For fuses above 600 A, use Class L time-delay fuses with element fuses as low as practical, typically 150% to 175% of ratings from 601-6000 A. While these fuses are not dual-element capacitor rated current. construction, the Bussmann series KRP-C-SP is a time-delay fuse. 10. Transformer primary fuse (without secondary fuse 1. Main service. Size fuse according to method in 4 below. protection). 450.3(b) When transformer primary current is equal to or greater than 9 amps, the dual-element, time-delay 2. Feeder circuit with no motor loads. (215.3) The fuse size fuse should be sized at 125% of transformer primary current or must be at least 125% of the continuous load plus 100% of the next size larger if 125% does not correspond to a standard the non-continuous load. Do not size larger than the conductors fuse size. Note: Secondary conductors must be protected from ampacity*. overcurrent damage per Article 240. 3. Feeder circuit with all motor loads. (430.62) Size the fuse at 11. Transformer primary fuse (with secondary fuse protection). 150% to 175% of the largest motors full load current** plus the 450.3(b) May be sized at 250% of transformer primary current full-load current** of all other motor s. if the secondary is fused per 12 below. 12. The secondary fuse is sized at no more than 125% of secondary full-load current. 450.3(b) Note: Secondary conductors must be protected at their ampacities per Article 240. 16-2 BUSSMANN SERIES FULL LINE CATALOG 1007 OCTOBER 2018 Eaton.com/bussmannseries

Tariff Desc

8547.90.00 TC 9904140 SPACERS, INSULATED, having a maximum outside diameter of 8 mm

3926.90.90 Other articles of plastics and articles of other materials ---Other

7415 Nails, tacks, drawing pins, staples (other than those of 8305) and similar articles, of copper or of iron or steel with heads of copper; screws, bolts, nuts, screw hooks, rivets, cotters, cotter-pins, washers (including spring washers) and similar articles, of copper:
7415.3 -Other threaded articles:
7415.33.00 --Screws; bolts and nuts
7415.39.00 --Other
Arrow Hart / Cooper
BUS
BUSSMANN
Bussmann Eaton
BUSSMANN / EATON
BUSSMANN BY EATON
COILTRONICS
Coiltronics Eaton
Coiltronics / Cooper Bussmann
Coiltronics / Eaton
Cooper
COOPER BUSSMAN
Cooper Bussmann
COOPER BUSSMANN / COILTRONICS
COOPER BUSSMANN / POWERSTOR
COOPER COILTRONICS
COOPER CROUSE-HINDS
Cooper Industries
Cooper Interconnect
Crouse-Hinds
CROUSE-HINDS/COOPER
CUTLER HAMMER/EATON
Cutler-Hammer / Eaton
Cutler-Hammer / Eaton
Eaton - Electronics Division
EATON AEROSPACE
EATON BUSSMAN ELECTRICAL
Eaton Bussmann
EATON BUSSMANN SERIES
EATON COILTRONICS
EATON CUTLER HAMMER
EATON ELECTRIC
Eaton Electro
Eaton Electronics
EATON HEINEMANN
EATON MOELLER
EATON POWERWARE
EATON SWITZERLAND
EATON/BUSSMANN
EATON/CUTLER-HAMMER
Garry Elec/WPI
HEINEMANN / EATON
Magnum / Cooper
MOELLER
Moeller / Eaton
PowerStor
PowerStor Eaton
POWERSTOR / COOPER
PowerStor / Cooper Bussmann
PowerStor / Eaton
Wirepro
WPI - WIRE-PRO INTERNATIONAL

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted