Loadcenters and Circuit Breakers 1.2 Type BR Loadcenters and Circuit Breakers Options and Accessories 1 1 Field Installation Kits and Parts BRSF125 Number Ampere Number of 1-Inch (25.4 mm) Wire Size Range Ordering Catalog 1 1 of Poles Rating Spaces Needed Cu/Al 60 C or 75 C Quantity Number Main and Sub-Feed Lug Blocks 1 2 125 2 82/0 1 BRSF125 2 150 2 82/0 1 BRSF150 1 3BRS225 225 4 2300 kcmil 1 BRS225 2 1 3 150 3 82/0 1 3BRSF150 225 6 2300 kcmil 1 3BRS225 1 Main Lugs Two-pole, 200 A stud mounted (includes deadfront filler plate) 1300 kcmil 1 BRL200 1 BRL200 Neutral/ground lug 2/0 maximum 1 NL20 Add-on neutral or ground lug 3/0 maximum 1 NL30 1 300 kcmil maximum 1 NL300 1 Filler Plates 1-inch (25.4 mm) circuit breaker space 25 BRFP 1 TDL BW main circuit breaker space (with hardware) 1 BWFP Door lock 1242 circuits, and 100225 A 1 TDL 1 Door lock48 circuits, 125 A 1 CH9FL 1 ANSI-61 light gray touchup paint for current loadcenters 1 SPC61 Isolated neutral assembly (computer circuits) 1 BINA 1 Circuit directoryadhesive backed 10 TCD Cover screws 25 LCCS 1 Cover replacement latch (gray) 14-5/16 (363.5 mm) wide loadcenters only 1 BRRL Circuit marking strip (next to breaker) 10 BRMS 1 Circuit identification label (preprinted breaker labels) 25 CHBL 1 Series rated caution label 25 SRL Bonding strip with screw 1 BSSUSE 1 Notes 1 Must be purchased in multiples of ordering quantities indicated. 1 2 82/0 wire size range is 75 C rated only. 1 1 1 1 1 1 1 1 1 1 1 V1-T1-60 Volume 1Residential and Light Commercial CA08100002ESeptember 2014 www.eaton.comLoadcenters and Circuit Breakers 1.2 Type BR Loadcenters and Circuit Breakers Field Installation Rainproof Conduit Hubs DS300H2 1 Conduit Size Ordering Catalog 1 Description Inches (mm) Quantity Number 1 Group 1for use with 70, 100 and 125 A MLO and MCB loadcenters and circuit breaker enclosures and the 0.75 (19.1) 1 DS075H1 following 150 and 200 A panels: BR48B200RF 1.00 (25.4) 1 DS100H1 1 1.25 (31.8) 1 DS125H1 1.50 (38.1) 1 DS150H1 1 2.00 (50.8) 1 DS200H1 1 Group 2for use with 150, 200 and 225 A MLO and MCB loadcenters and circuit breaker enclosures except for 2.00 (50.8) 1 DS200H2 the following 200 A loadcenters: BR48B200RF. Also for use with 400 and 600 A loadcenters and New York City 2.50 (63.5) 1 DS250H2 loadcenters manufactured after November 1, 2005 1 3.00 (76.2) 1 DS300H2 Type H conduit hubs for loadcenters PL0724R and S3100RN 0.75 (19.1) 1 RH75P 1 1.00 (25.4) 1 RH100P 1.25 (31.8) 1 RH125P 1 1.50 (38.1) 1 RH150P 1 Adapter kitAllows Installing a Group 1 hub on devices arranged for Group 2 hubs 1 DS900AP Group 1 small blank hub plate with bump 1 DS900CP1 1 Group 2 Large blank hub plate with bump 1 DS900CP2 1 Ground Bar Kits GBK14 1 Description Length Ordering Catalog 1 (See Legend) Inches (mm) Quantity Number 1 2 2.54 (64.5) 1 GBK5 dssssds 2 BRGBK39512 dssssdsj 3.59 (91.2) 1 GBK520 1 2 4.29 (109.0) 1 GBK10 dssssdssssss 2 1 dssssdssssssj 5.34 (135.6) 1 GBK1020 2 4.61 (117.1) 1 GBK13 1 2 dssssdssssssssss 5.69 (144.5) 1 GBK14 2 6.74 (171.2) 1 GBK1420 dssssdssssssssssj 1 2 dssssdsssssssssssssssss 8.14 (206.8) 1 GBK21 2 9.19 (233.4) 1 GBK2120 1 dssssdsssssssssssssssssj 34 5.78 (146.8) 1 BRGBK39512 1 5 1.84 (46.7) 1 GB4NM sssss Ground Bar Legend 1 s (3) 1410 Cu/Al or (1) 144 Cu/Al j (1) 62/0 Cu/Al 1 (1) 141/0 Cu/Al or (3) 1410 Cu/Al (1) 146 Cu/Al or (2) 1412 Cu/Al 1 d Mounting Hole Notes 1 1 Must be purchased in multiples of ordering quantities indicated. 2 Distance between mounting holes is 1.75 inches (44.5 mm). 1 3 For single- and three-phase 400 and 600 A applications. 4 Distance between mounting holes is 2.34 inches (59.5 mm). 5 For non-metallic enclosures. Snaps into molded base. 1 1 1 1 1 1 Volume 1Residential and Light Commercial CA08100002ESeptember 2014 www.eaton.com V1-T1-65 fk f k f d f k f f d f f f f k f f k d f f d k f f k f f f f k f f