TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC 030AAC Highlights & Features MDS-030AAC05, 12, 15, 24 Meet Efficiency Level VI Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 62368-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Meets Limited Power Source (LPS) requirements Low touch current. Suitable for type BF applications Detachable AC plug with multiple country options IP22 ingress protection rating 2 MOPP isolation 500K hours MTBF Safety Standards CB Certified for worldwide use Model Number: MDS-030AAC Unit Weight: 150 grams Dimensions (W L H): 53.5 88.0 27.5 mm 2.11 3.46 1.08 inch General Description The MDS series of external power supply comes with universal AC input at 85 Vac to 264 Vac. Other features include low touch current, risk management report available and the electric shock protection comply with 2 MOPP. The MDS series is certified for EMC standards according to EN/BS EN 55011 for industrial, scientific and medical (ISM) radio-frequency equipment and EN/BS EN 55032 for Information Technology Equipment (ITE) radio-frequency equipment. In addition, only recognized Japanese capacitors are used. The MDS series come with both medical and ITE safety approvals including UL/cUL and IEC 60950-1 CB certification as a Limited Power Source (LPS), and CCC approval. Designs are fully compliant with RoHS Directive for environmental protection. Model Information Medical AC-DC Adapter Model Number Input Voltage Range Efficiency Level Rated Output Voltage Rated Output Current MDS-030AAC05 85-264Vac Level VI 5 Vdc 3 A MDS-030AAC12 Level VI 12 Vdc 2 A MDS-030AAC15 Level VI 15 Vdc 2 A MDS-030AAC24 Level VI 24 Vdc 1.25 A Model Numbering MDS 030 AAC 1 2 Delta Medical Max wattage in the Family Code Output Voltage (Single Revision Code Revision Code Power Supply product series Output) DC plug type and output cable length Country duck-head type - 05 for 5 V - 12 for 12 V A 2.1 x 5.5 x10mm DC plug A China B United States - 15 for 15 V B 2.1 x 5.5 x12mm DC plug C European D United Kingdom - 24 for 24 V Both A & B are 1200mm cable length E Australia GKorea H India, J Argentina K Brazil MSouth Africa * MDS-030AAC15 BB is not available. All parameters are specified at 25C ambient unless otherwise indicated. 1 www.DeltaPSU.com (October 2021, Rev.13) TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC Specifications Model Number MDS-030AAC05 MDS-030AAC12 MDS-030AAC15 MDS-030AAC24 Input Ratings / Characteristics Nominal Input Voltage 100-240 Vac Input Voltage Range 85-264 Vac Nominal Input Frequency 50-60 Hz Input Frequency Range 47-63 Hz Input Current (max) 115 Vac 0.5 A 0.6 A 0.8 A 0.8 A 230 Vac 0.3 A 0.4 A 0.6 A 0.6A Average Efficiency (min) 115 Vac 81.4% 86.21% 87.0% 87.0% 230 Vac Standby Power (max) 115 Vac 0.1W 0.1 W 0.1 W 0.1 W 230 Vac Inrush Current (typ.) 60 A 115 Vac and 100 A 230 Vac 1) 2) Touch Current (max) 0.1 mA 264 Vac NC , 0.3 mA 264 Vac SFC 1) 2) Output-PE (protective earth) 0.1 mA 264 Vac NC , 0.5 mA 264 Vac SFC leakage current for Type BF application (max) 1) NC: Normal condition 2) SFC: Single fault condition Model Number MDS-030AAC12 MDS-030AAC15 MDS-030AAC24 MDS-030AAC05 Output Ratings / Characteristics Nominal Output Voltage 5 Vdc 12 Vdc 15 Vdc 24 Vdc Output Total Regulation 6% Output Current 3 A 2 A 2 A 1.25 A Output Power 15 W 24 W 30 W 30 W Line Regulation 1% Load Regulation 5% Ripple & Noise (max) 100 mVpk-pk 150 mVpk-pk 200 mVpk-pk 200 mVpk-pk Rated load Rated load Rated load Rated load Start-up Time (max) 3000 ms 115 Vac Hold-up Time (min) 10 ms 115 Vac Dynamic Response (Overshoot & 10% 50-100% load Undershoot O/P Voltage) Capacitive load (max) 4700 uF *Periodic and Random Deviation. Ripple & Noise measurement circuit with 20 MHz BW PSU Load 0.47uF Ceramic Scope 5cm 10uF Electrolytic Test Fixture All parameters are specified at 25C ambient unless otherwise indicated. 2 www.DeltaPSU.com (October 2021, Rev.13)