Product Information

CMA-4544PF-W

CMA-4544PF-W electronic component of CUI Devices

Datasheet
20 Hz ~ 20 kHz Analog Microphone Electret Condenser 3 V ~ 10 V Omnidirectional (-44dB ±2dB) PC Pins

Manufacturer: CUI Devices
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (AUD)

1: AUD 0.9844 ( AUD 1.08 Inc GST) ea
Line Total: AUD 0.9844 ( AUD 1.08 Inc GST)

18740 - Global Stock
Ships to you between
Thu. 11 Jul to Wed. 17 Jul
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
10234 - Global Stock


Ships to you between Wed. 17 Jul to Fri. 19 Jul

MOQ : 1
Multiples : 1

Stock Image

CMA-4544PF-W
CUI Devices

1 : AUD 1.2242
10 : AUD 0.9437
100 : AUD 0.9121
200 : AUD 0.8545
500 : AUD 0.8062
1000 : AUD 0.7598
2000 : AUD 0.7598
5000 : AUD 0.6762
10000 : AUD 0.6651

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Directional Properties
Impedance
Current Rating
Sensitivity
Termination Style
Depth
Diameter
Operating Supply Voltage
Frequency
Packaging
Brand
Mounting
Cnhts
Hts Code
Product Type
Factory Pack Quantity :
Subcategory
Taric
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.

Additional Resources: Product Page 3D Model PCB Footprint date 01/17/2020 page 1 of 4 MODEL: CMA-4544PF-W DESCRIPTION: ELECTRET CONDENSER MICROPHONE SPECIFICATIONS parameter conditions/description min typ max units directivity omnidirectional sensitivity (S) f = 1 kHz, 1 Pa, 0 dB = 1 V/1 Pa -46 -44 -42 dB operating voltage 3 10 Vdc output impedance (Zout) f = 1 kHz, 1 Pa 2.2 K sensitivity reduction (S-Vs) f = 1 kHz, 1 Pa, Vs = 3.0 to 2.0 Vdc -3 dB frequency (f) 20 20,000 Hz current consumption (IDSS) Vs = 3.0 Vdc, RL = 2.2 K 0.5 mA signal to noise ratio (S/N) f = 1 kHz, 1 Pa, A-weighted 60 dBA operating temperature -20 70 C storage temperature -20 70 C dimension 9.7 x 4.5 mm weight 0.8 g material Al terminal pin type (hand soldering only) RoHS yes Note: We use the Pascal (Pa) indication of sensitivity as per the recomendation of I.E.C. (International Electrotechnical Commission). The sensitivity of Pa will increase 20dB compared to the ubar indication. Example: -60dB (0dB = 1V/ubar) = -40dB (1V/Pa) MECHANICAL DRAWING MEASUREMENT CIRCUIT unit: mm RL = 2.2 K Schematic Diagram cuidevices.com Additional Resources: Product Page 3D Model PCB Footprint CUI Devices MODEL: CMA-4544PF-W DESCRIPTION: ELECTRET CONDENSER MICROPHONE date 01/17/2020 page 2 of 4 FREQUENCY RESPONSE CURVE 1.000V/PA MECHANICAL CHARACTERISTICS item test condition evaluation standard Soldering iron of +270 5C should be placed on the soldering heat resistance No interference in operation. terminal for 2 0.5 seconds. terminal mechanical strength Apply to the terminal 4.9 N (0.5 kg) for 30 seconds No damage or cutting off. The part should be measured after a vibration amplitude of vibration test 1.5 mm with 10~55 Hz band of vibration frequency to each of the 3 perpendicular directions for 2 hours. After any tests, the sensitivity should be within 3 dB of the initial sensitivity. The part without packaging is subjected to 3 drops on each drop test axis from the height of 1 m onto a 20 mm thick wooden board. ENVIRONMENT TEST item test condition evaluation standard high temperature test After being placed in a chamber at +70C for 72 hours. low temperature test After being placed in a chamber at -20C for 72 hours. After being placed in a chamber at +40C and 90 5% RH thermal shock for 240 hours. The part will be subjected to 10 cycles. One cycle will consist of: After any tests and 6 hours of conditioning at +25C, the sensitivity should be within 3 dB of the initial sensitivity. temperature cycle test TEST CONDITIONS standard test conditions a) Temperature: +5 ~ +35C b) Humidity: 45 ~ 85% c) Pressure: 860 ~ 1060 mbar judgement test conditions a) Temperature: +25 2C b) Humidity: 60 ~ 70% c) Pressure: 860 ~ 1060 mbar cuidevices.com

Tariff Desc

8543.70.00 - Other machines and apparatus Free
13 No Signal processors (graphic equalisers, crossovers etc.)
91 .. Other

9027.10.00 Instruments and apparatus for physical or chemical analysis (for example, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes.

9031.80.00 - MEASURING OR CHECKING INSTRUMENTS, APPLIANCES AND MACHINES, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER; PROFILE PROJECTORS Other instruments, appliances and machines Free

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted