Product Information

TRH70A120-11E01-Level-VI

TRH70A120-11E01-Level-VI electronic component of Cincon

Datasheet
Desktop AC Adapters Switching Adapter, Level VI, Desktop, 70 Watt, 90-264VAC Input, ITE & Industrial, 12VDC Output, 5.5x2.1x12mm, Straight, DC Cable 720mm

Manufacturer: Cincon
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (AUD)

1: AUD 50.4 ( AUD 55.44 Inc GST) ea
Line Total: AUD 50.4 ( AUD 55.44 Inc GST)

1363 - Global Stock
Ships to you between
Wed. 17 Jul to Fri. 19 Jul
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
628 - Global Stock


Ships to you between Wed. 17 Jul to Fri. 19 Jul

MOQ : 1
Multiples : 1
1 : AUD 44.5846
5 : AUD 42.7269
10 : AUD 40.8693
25 : AUD 39.0115
50 : AUD 37.8412

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
AC Plug included/required
Region
Input Voltage
Number of Outputs
Output Power
Output Voltage-Channel 1
Output Current-Channel 1
Industry
DC Output Connector
Efficiency
Series
Commercial/Medical
Dc Output Cord Length
Brand
Mounting Style
Load Regulation
Factory Pack Quantity :
Height
Isolation Voltage
Operating Temperature Range
Width
Cnhts
Cooling Method
Hts Code
Input Voltage Max
Input Voltage Min
Mechanical Style
Output Voltage V1 Nominal
Product Type
Subcategory
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.

V11 TRH70A SERIES 70W SWITCHING ADAPTER Features * Universal Input Range 90~264VAC * Meets EN55032 Class B and CISPR/FCC Class B * Continuous Short Circuit Protection * Over Voltage Protection * Meet CoC Tier 2 & DoE Level VI * No load Power Consumption<150mW * Approved IEC62368-1, UL62368-1, EN62368-1 (Output Cable Length1800mm) (TRH70A120:Output Cable Length720mm) (TRH70A150:Output Cable Length1220mm) (TRH70A180, TRH70A190: Output Cable Length1800mm 16AWG) Ordering information TRH70XXX - E XX -XX Model No. DC Plug Type OVP DC Cable Length and Type 01: 720mm 02: 1220mm 03: 1800mm 11: 720mm with Ferrite Core 12: 1220mm with Ferrite Core 13: 1800mm with Ferrite Core * 16AWG / UL1185 FOR 12V,15V,18V,19V * 18AWG / UL1185 FOR 24V,28V,36V,48V OUTPUT OUTPUT RIPPLE & VOLTAGE LINE LOAD AVERAGE VOLTAGE CURRENT NOISE ACCURACY REGULATION REGULATION EFFICENCY min. MODEL NOTE 1 NOTE 2 NOTE 3 NOTE 4 NOTE 5 TRH70A120 12V 5.80A 1% 2% 1% 4% 89% TRH70A150 15V 4.65A 2% 1% 3% 89% 1% TRH70A180 18V 3.90A 2% 1% 2% 89% 1% TRH70A190 19V 3.70A 2% 1% 2% 89% 1% TRH70A240 24V 3.00A 2% 1% 2% 89% 1% TRH70A280 28V 2.50A 2% 1% 2% 89% 1% TRH70A360 36V 2.00A 1% 2% 1% 2% 89% TRH70A480 48V 1.50A 1% 2% 1% 2% 89% Specifications are subject to change without notice. 1 V11 Specifications TRH70A Series Derating Curve INPUT SPECIFICATIONS: Voltage ..................................................................... 90~264Vac Frequency ...... 47 to 63Hz Input Current ...............................1.5A max. Inrush Current ..................... Cold Start 25 100A max. 240Vac Leakage Current ..... 3.5mA max. OUTPUT SPECIFICATIONS: Hold-up Time 8ms typ. 115Vac Short Circuit Protection . Continuous(Auto Recovery) Over Voltage Protection .. TVS Component to Clamp Temperature Coefficient ............................ 0.05%/ GENERAL SPECIFICATIONS: NOTE: Isolation Input to output = 3000VAC 1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for Operating Temperature .............................. -20 ~ 70 (see derating curve) Ripple & Noise measuring 20MHz BW. Storage Temperature .................. -20 ~ 85 2. Voltage setpoint at 60% full load. Humidity ................ 93% RH max. Non condensing 3. Line regulation measured from 100Vac to 240Vac full load. Cooling . Natural Convection 4. Load regulation measured from 60% to full load and from 60% to Switching Frequency .. 65KHz Typical 20% load (60% +/- 40% load). 5. Average Efficiency measured at 25%,50%,75%,100% load and input MTBF MIL-HDBK-217F, GB, at 25 /115VAC . 200Khrs min. Altitude 5000m voltage is 115Vac / 230Vac Dimensions ... 4.724x2.047x1.220 inches (120.00x52.00x31.00mm) Weight 300g AC Inlet .. IEC320/C14 SAFETY AND EMC: Emission and lmmunity EN55032 Class B, FCC Part 15 Class B EN61000-6-3,EN61000-3-2,EN61000-3-3 EN55024, EN61204-3, EN61000-6-1 Safety Class I, IEC62368-1/60950-1, UL62368-1/60950-1 EN62 3 68- 1/ 60 95 0- 1 Mechanical Specification All Dimensions are in inches(mm) Tolerance:Inches:X.XXX0.02 Millimeters:X.XX0.5 DC Plug type: V+ ) V- DC Plug :Right Angle(5.52.1) L12mm 18AWG1800mm Typical at 25C, nominal line and 75% load, unless otherwise Specified 2

Tariff Desc

8504.40.90 POWER SUPPLIES, having BOTH:
(a) input voltages of 176V-246VAC, 47Hz-63Hz single phase OR 200V-230VAC, 50Hz-60Hz single phase
(b) multiple DC output voltages from minus 200 V to positive 200V
TC 9603032

8504.40.90 CHARGERS, ADAPTERS AND INVERTERS, AC/DC OR DC/DC OR DC/AC having ALL of the following:
(a) input voltage NOT less than 10V and NOT greater than 252V
(b) output voltage NOT less than 2V and NOT greater than 252V
(c) wattage NOT less than 40 W and NOT greater than 160W
(d) output current NOT greater than 17A - TC 1021920

8504.50.10 81
(a) designed for use with equipment of 8471
(b) for telecommunication apparatus of 8517 Free

8504.40.90 POWER SUPPLY UNITS, DC AND/OR AC output, complying with AS/NZS 60950 & AS/NZS CISPR 22, having ALL of:
(a) voltage NOT less than 2.5 V and NOT greater than 55V
(b) wattage NOT less than 0.02 W and NOT greater than 105W
(c) current output NOT less than 0.01 amp and NOT greater than 2.5amp
TC 1014564

8504.40.90 POWER SUPPLY MODULES having ALL of the following:
(a) input power at EITHER of the following voltages:
(i) 120VAC/240VAC
(ii) 24VDC /48VDC
(b) output power at EITHER of the following voltages:
(i) 5VDC, +15VDC, -15VDC, and 24VDC field I/O
(ii) 24VDC field I/O only
(c) circuitry monitors
(d) output adjusters
TC 9810001

8504.40.90 POWER SUPPLIES DC having BOTH:
(a) variable voltage NOT exceeding 30V
(b) maximum current output NOT exceeding 25amps
TC 9900597

8504.40.90 CONVERTERS, DC/DC, power output not exceeding 5W, being ANY of:
(a) single in line package
(b) dual in line
(c) surface mount device
TC 9601650

8543.90.20 20 Electronic microassemblies Free

8504.40.30 Static converters
(a) separately housed units, designed to be housed in the same cabinet as the central processing unit of equipment of 8471
(b) for telecommunication apparatus of 8517
60 No Electric current rectifying assemblies Free
63 No Other Free

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted