Product Information

CTD1X1005AXXX

Hot CTD1X1005AXXX electronic component of Carlo Gavazzi

Datasheet
Current Transformers CURRENT TRANSFORMER 100:5A

Manufacturer: Carlo Gavazzi
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (AUD)

1: AUD 48.195 ( AUD 53.01 Inc GST) ea
Line Total: AUD 48.195 ( AUD 53.01 Inc GST)

1 - Global Stock
Ships to you between
Fri. 12 Jul to Thu. 18 Jul
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
10 - Global Stock


Ships to you between Fri. 12 Jul to Thu. 18 Jul

MOQ : 1
Multiples : 1

Stock Image

CTD1X1005AXXX
Carlo Gavazzi

1 : AUD 128.8673
5 : AUD 122.426
10 : AUD 116.3077

2 - Global Stock


Ships to you between Thu. 18 Jul to Mon. 22 Jul

MOQ : 1
Multiples : 1

Stock Image

CTD1X1005AXXX
Carlo Gavazzi

1 : AUD 114.9912
5 : AUD 110.4584
10 : AUD 108.7122
25 : AUD 105.164

1 - Global Stock


Ships to you between Fri. 12 Jul to Thu. 18 Jul

MOQ : 1
Multiples : 1

Stock Image

CTD1X1005AXXX
Carlo Gavazzi

1 : AUD 48.195
2 : AUD 45.57

     
Manufacturer
Product Category
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.

Accessories AC Current Transformer (max 23mm cable) Type CTD-1X Cable and bus-bar type current transformer 0.5 class, currents from 50 to 300 A Removable DIN-rail mounting holder Removable panel fixing clips 2 cable/bus-bar isolated fixing screws Double screw terminals (up to 8-wire connections) Sealable terminal block covers Product Des cript ion Ordering Key CTD-1X 100 5A XXX Cable/Bus-bar type current Rated primary currents from Model transformer with DIN-rail/bus- 50 A to 300 A. Primary current bar and panel mounting Secondary current facility. Option Optional fixing kit: CTD-kit Type Selection Primary current Secondary current Option From 50 to 300A 1A XXX: none (Refer to Range Table) 5A XTX: tropicalization Input Specifications Operating frequency 48 to 62 Hz Two panel mounting fixing clips. Max. system voltage 0.72 kV Special features 1 A secondary current, Rated insulation level 3 kV/1 min. 50 Hz Tropicalization Insulation class E (max 75C) Working temperature -25C to +60C (-13F to Short-time current rating 140F) (R.H. < 90% non condensing 40C) I Typical 100 I /1 s th n I 2.5 I dyn th Storage temperature -30C to +70C (-22F to The short-time thermal 158F) (R.H. < 90% non condensing 40C) current I is anyway limited th by the cable/bus-bar size Approvals CE, cUrus and CSA Connection Screw type Extended current rating 120% 2 Cable cross section area From 1.5 to 6 mm Security factor (FS) 5 (Class: 0.5, 1 and 3) Min/Max screws tightening torque relevant to terminal block screws: General Specifications From 1 to 2 Nm Max screws tightening Standards According to EN61869-2 torque relevant to the Housing ABS, self-extinguishing: cable/bus-bar fixing UL 94 V-0 screws: 0,3 Nm Mounting DIN-rail bus-bar Protection degree IP00 and panel mounting IP20 (with sealable terminal block covers + wire termi Standard accessories Two terminal block screws. nals) Two sealable terminal block covers. Cable diameter Max. 23 mm Two panel mounting Bus-bar size Max. 20x5 mm fixing clips. Weight From 150 to 200 g One DIN rail adapter. Optional accessories Extended fixing kit CTD-kit: Six cable/bus-bar fixing screws. Output Specifications Six plastic caps for cable/bus-bar fixing Rated secondary current 5 A or 1 A screws. Specifications are subject to change without no tice CTD-1X DS ENG 140116 1CTD-1X Range Table Model CTD-1X from 50A to 100A Model CTD-1X from 120A to 300A Primary Primary Burden (VA) Burden (VA) Current Current A CL 0.5 CL 1 CL 3 A CL 0.5 CL 1 CL 3 50 ( 60C/140F) 1 1.25 120 ( 60C/140F) 1.75 2 2.5 60 ( 60C/140F) 1 1.25 125 ( 60C/140F) 2 2.25 2.75 70 ( 60C/140F) 1.5 1.75 150 ( 60C/140F) 2.25 2.5 3 75 ( 60C/140F) 1 1.25 1.75 160 ( 60C/140F) 2.5 2.75 3.25 80 ( 60C/140F) 1.25 1.5 2 200 ( 60C/140F) 3 3.25 3.75 100 ( 60C/140F) 1.5 1.75 2.25 250 ( 50C/122F) 4.5 4.75 5.25 300 ( 50C/122F) 5 5.5 6 Benefits 1 2 3 4 5 10 6 7 8 9 Easy and quick mounting either on a panel or Dimensions (mm) on a DIN-rail (see figure 1-2). Protection of screw terminals using specific 44 sealable covers to assure always the best 30 safety (see figure 3). Bridging of current transformer output without changing the connection of the secondary, so to avoid any output overvoltage during either the maintenance or the installation procedure (see figure 4). Easy output and earth connection (see fig. 5). Screw terminals compatible with any kind of wire terminals (see figure 6-7-8-9). Multiple screws provided with insulation caps to grant a strong and reliable fixing of the current transformer to the bus-bar (see figure 10). Wiring Diagram S1 S2 22 44 69,2 L 46 P1 P2 N 2 Specifications are subject to change without no tice CTD-1X DS ENG 140116 23,3 27 65,2 83,6

Tariff Desc

8504.31.00 TC9500870 TRANSFORMERS, output, ferrite core, frequency within the range 20-50KHz, nominal power rating NOT greater than 100W

8504.31.00 TC1224368 TRANSFORMERS, LED, NOT less than 24VDC and NOT greater than 35VDC

8504.40.30 as follows
(a) separately housed units, designed to be housed in the same cabinet as the central processing unit of equipment of 8471
(b) for telecommunication apparatus of 8517
60 Electric current rectifying assemblies
Free

8504.31.00 TC702370 TRANSFORMERS, CURRENT AND/OR VOLTAGE, having ANY of the following
(a) current transformer voltage rating GREATER than 400kV
(b) voltage transformer voltage rating GREATER than 72kV
(c) combined current and voltage transformer voltage rating GREATER than 72kV

8504.34.00 TC513212 TRANSFORMERS, having ALL of the following
(a) primary and secondary winding
(b) primary voltage NOT less than 500kV
(c) greater than 330 MVA rating

8504.31 TC8343084 AUTOTRANSFORMERS, toroidal core, continuously variable from zero voltage

8504.31 TC8343083 TRANSFORMERS, radio frequency, power rating 100W continuous, frequency range 1.4MHz or greater but NOT exceeding 200.0MHz, input impedance 75ohms, output impedance 50ohms

8504.33.00 TC1761475 CURRENT TRANSFORMER MODULES, with OR without voltage measurement outputs, having NOT greater than 4 poles

8504.31.00 TRANSFORMERS, RF pulse, dual in-line packaging (DIP) TC9209172

8504.31.00 TC 1056338 TRANSFORMERS, TOROIDAL, STEP DOWN, isolated OR auto-wound, enclosed, complying with Australian & NZ Standards AS/NZS61558.1:2008, AS/NZS3820:2009 & AS/NZS3191:2008, including ALL of the following
(a) input voltage NOT less than 230V and NOT greater than 250V
(b) output voltage NOT less than 100V and NOT greater than 120V
(c) female 3 slot output chassis sockets rated at NOT greater than 20A
(d) rated Voltage Amps NOT less than 0.05kVA & NOT greater than 4kVA
(e) thermal fuse or thermal cut out protectors
Carlo Gavazzi Computing Solutions

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted