Product Information

KCA77AB0

KCA77AB0 electronic component of Bourns

Datasheet
Thermal Cutoffs Trip Temp 77c 5c TOL

Manufacturer: Bourns
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (AUD)
N/A

Obsolete
Availability Price Quantity
0 - Global Stock

MOQ : 1
Multiples : 1

Stock Image

KCA77AB0
Bourns

1 : AUD 0.5926
N/A

Obsolete
0 - Global Stock

MOQ : 4000
Multiples : 4000

Stock Image

KCA77AB0
Bourns

4000 : AUD 1.3
N/A

Obsolete
0 - Global Stock

MOQ : 1
Multiples : 1

Stock Image

KCA77AB0
Bourns

1 : AUD 2.211
10 : AUD 2.112
25 : AUD 1.991
50 : AUD 1.694
100 : AUD 1.441
250 : AUD 1.397
500 : AUD 1.177
1000 : AUD 1.1289
2500 : AUD 1.0855
N/A

Obsolete
0 - Global Stock

MOQ : 18
Multiples : 18

Stock Image

KCA77AB0
Bourns

18 : AUD 0.5926
N/A

Obsolete
     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Contact Rating
Rated Temperature
Maximum Voltage
Minimum Holding Voltage
Resistance
Maximum Breaking Current
Maximum Leakage Current
Length
Width
Height
Series
Packaging
Current Rating
Operating Temperature Range
Product
Voltage Rating
Brand
Tradename
Cnhts
Hts Code
Mxhts
Product Type
Reset Temperature
Factory Pack Quantity :
Subcategory
Taric
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.

Features n Formerly a This series is currproduct ently available but not recommended for new designs. n Miniature Thermal Cutoff (TCO) device The Model AA Series is a possible n High current type replacement. n Optimal corrosion resistant properties n Smallerbody size: L5.4 x W3.2 x H0.89 mm n Overtemperatureand overcurrent protection for lithium polymer and prismatic cells n Wide range of temperature options KCA Series A-Type Breaker(Thermal Cutoff Device) RatingsRatings Model Specification KCA72AB0 KCA77AB0 KCA82AB0 KCA85AB0 Trip Temperature 72 C 5 C 77 C 5 C 82 C 5 C 85 C 5 C Reset Temperature 40 C min. Contact Rating DC12V / 25 A, 6000 cycles Maximum Breaking Current DC5V / 60 A, 100 cycles Maximum Voltage DC28V / 25 A, 100 cycles Minimum Holding Voltage 2 V 25 C for 1 minute Maximum Leakage Current 200 mA max. 25 C Resistance 5 milliohms max. Product Dimensions Agency Recognition 2.9 0.1 5.4 0.1 Description (.114 .004) (.213 .004) 2.9 0.1 UL, cUL File Number: E215638 (.114 .004) 0.1 0.01 (.004 .0004) TUV File Number: R50305080 0.89 0.05 How to Order 2.3 0.1 2.3 0.1 (.035 .002) (.091 .004) (.091 .004) KCA 77 A B 0 3.2 0.1 MM DIMENSIONS: Series Designator (.126 .004) (INCHES) Trip Temperature (5 C) 72 82 77 85 Arm Material Product Structure A = Cu Alloy, High Current Type Terminal Type COVER COVER PLATE ARM (with/without Projection & Terminal Length) ARM TERMINAL CONTACT Manufacturer s Internal Code PROJECTION PROJECTION PTC BASE BIMETAL DISC BASE TERMINAL AVAILABLE WITH AND WITHOUT PROJECTIONS. * RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011. ** Bourns considers a product to be halogen free if (a) the Bromine (Br) content is 900or less ppm (b) the Chlorine (Cl) content is 900 ppm or less and (c) the total Bromine (Br) and Chlorine (Cl) content is 1500 ppm or less. Specifications are subject to change without notice. Users should verify actual device performance in their specific applications. The products described herein and this document are subject to specific disclaimers as set forth on the last page of this document,www.bourns.com/legal/disclaimer.pdf and at . *RoHS COMPLIANT & **HALOGEN FREE *RoHS COMPLIANT LEAD FREE LEAD FREE VERSIONS ARE RoHS COMPLIANT*Applications Battery cell protection for: n Notebook PCs n Tablet PCs n Smart phones n Mobile phones KCA Series A-Type Breaker (Thermal Cutoff Device) Typical Performance Current vs. Temperature Curves KCA72ABO (Low 67 C average) 22 KCA77ABO (Low 72 C average) 21 20 KCA82ABO (Low 77 C average) 19 18 KCA85ABO (Low 80 C average) 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 20 30 40 50 60 70 80 Temperature (C) The above curves were derived from placing test samples in an oven at 25 , 40 , 60 and 70, increasing current flow through the sample at a rate of 0.1 A/minute and recording the current value when the sample trips. Operation NORMAL CIRCUIT CURRENT EXCESSIVE CURRENT AND/OR HEAT CIRCUIT AFTER OPENING VERY LOW CURRENT Specifications are subject to change without notice. Users should verify actual device performance in their specific applications. The products described herein and this document are subject to specific disclaimers as set forth on the last page of this document,www.bourns.com/legal/disclaimer.pdf and at . Current (A)

Tariff Desc

8536.20.00 PROTECTORS, THERMAL, bimetal disc, having BOTH of the following:
(a) a cut off temperature of 60 degrees C, or greater but NOT exceeding 350 degrees C;
(b) a current rating NOT exceeding 25 A
Op. 27.10.1997 Dec. 09.01.1998 - TC 9709468
BOURNS
Bourns Inc.
BOURNS JW MILLER
BR4
J.W. Miller
JW Miller

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted