Dimensions: mm Recommended Land Pattern: mm General Properties: Type Optocoupler Darlington Input DC Package SOP 4 2 7,4 3 Plastic Housing Color White 5,2 4 1 Certification: 1 4 RoHS Approval Compliant 2011/65/EU&2015/863 7,0 0,3 REACh Approval Conform or declared (EC)1907/2006 Halogen Free Conform JEDEC JS709B 2 3 Halogen Free Conform IEC 61249-2-21 40051484 DIN EN 60747-5-5 (VDE0884-5) EN 5,2 0,3 VDE Approval 60747-5-5:2011 A1:2015 4,4 0,2 UL Approval E513104 UL 1577 CQC Approval CQC20001274583 GB4943.1-2001 GB8898-2011 Schematic: 0,5 typ. General Information: Operating Temperature -55 up to +110 C 4 1 Anode Collector Storage Conditions (for single -55 up to +125 C parts) 1 4 Storage Conditions (in original < 40 C < 75 % RH packaging) 2 3 Cathode Emitter Moisture Sensitivity Level (MSL) 1 2 3 Scale - 5:1 Product Marking: Pin 1 Anode o CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD Marking 355 SaVog 001.001 2022-01-07 DIN ISO 2768-1m Marking - Date Code YWW DESCRIPTION WL-OCDA - Optocoupler Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Darlington Max-Eyth-Str. 1 141355145000 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com SOP4 eiPal Valid 1/13 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 3,6 0,2 0,2 typ. 0,4 typ. 2,54 typ. 2,0 0,1 0,1 typ. 2,1 typ. 1,64 3,44Absolute Maximum Ratings Input Properties (Ambient Temperature 25 C unless Electrical & Optical Output Properties: otherwise specified): Value Properties Test conditions Unit Properties Test conditions Value Unit min. max. Forward Current I 60 mA V = 10 V F max. Collector-Emitter Dark Current I 100 nA CE I = 0 I CEO.Dark Peak Forward Current duty/ 100 100 Hz 1 A F F Peak P Input Power Dissipation 100 mW I = 100 A I Collector-Emitter Breakdown V C 40 V I = 0 Voltage (BR)CE Reverse Voltage V 6 V F REV I = 100 A Emitter-Collector Breakdown V E 6 V Absolute Maximum Ratings Output Properties: I = 0 Voltage (BR)EC F Properties Value Unit V Electrical & Optical Transfer Properties: Collector Emitter Voltage 40 V CE V Emitter Collector Voltage 6 V Value EC Properties Test conditions Unit I Collector Current 80 mA min. typ. max. CE.P P Output Power Dissipation 150 mW I = 1 mA O Current Transfer Ratio CTR F 600 7500 % V = 2 V CE Absolute Maximum Ratings Common Properties: I = 20 mA Collector-Emitter Saturation V 0.7 1 V F I = 5 mA Voltage Properties Test conditions Value Unit CEsat C P Power Dissipation 1) 200 mW Diss V = 2 V V CE Isolation Voltage AC for 1 Minute, RH 40~60 % 3750 V (RMS) t I = 10 mA Rise Time 95 300 s ISO r C R = 100 1) Total power dissipation of the whole component L V = 2 V Electrical & Optical Input Properties: CE t I = 10 mA Fall Time 90 250 s f C Value R = 100 L Properties Test conditions Unit typ. max. V = 2 V CE V I = 10 mA Forward Voltage 1.24 1.4 V I = 10 mA F F Cut-Off Frequency f 1 kHz C R = 100 c Reverse Current I V = 6 V 10 A L -3 dB REV REV V = 0 V Input Capactiance C 10 pF V = 0 V f = 1 kHz in C Floating Capacitance 0.6 pF IO f = 1 MHz DC = 500 V Isolation Resistance R 1 100 T 40~60 % R.H. ISO CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD SaVog 001.001 2022-01-07 DIN ISO 2768-1m DESCRIPTION WL-OCDA - Optocoupler Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Darlington Max-Eyth-Str. 1 141355145000 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com SOP4 eiPal Valid 2/13 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.