Issued by Module Components Div, TAMURA CORPORATION Hall Effect Current Sensors S26P200D15Y Features: Advantages: Closed Loop type Excellent accuracy and linearity Current or voltage output Low temperature drift Conversion ratio K = 1:2000 Wide frequency bandwidth N Printed circuit board mounting No insertion loss Aperture High Immunity to external interferences Insulated plastic case according to Optimised response time UL94V0 Current overload capability Specifications UL Recognition T =25C, V =15V A CC Symbol S26P200D15Y Parameters Primary nominal current I 200A 300A f 1 Maximum current (at 85C) 350A (at R 5) I M fmax 2 0 ~ 4 (at V = 12V) 0 ~ 26 (at V = 12V) CC CC Measuring resistance (at 85C) R M 0 ~ 56 (at V = 15V) 0 ~ 8 (at V = 15V) CC CC Conversion Ratio K 1 : 2000 N Rated output current I 100mA 150mA O 3 Output current accuracy (at I ) X I 0.4% f O 4 Offset current (at If=0A) I 0.2mA Of 3 Output linearity (0AIf) 0.15% (at I ) f L 1 Power supply voltage V 12V .. 15V 5% CC Consumption current I 16mA (Output current is not included) CC 5 Response rime 1.0s (at di/dt = 100A / s) t r 6 Thermal drift of gain TcIo 0.01% / C Thermal drift of offset current TcIof 0.5mA max (at T = 40C +85C) A Hysteresis error I 0.3mA ( I =0A I I =0A) OH f f f Insulation voltage V d AC 3000V, for 1minute (sensing current 0.5mA), inside of through hole terminal Insulation resistance R 500M ( DC 500V) , inside of through hole terminal IS Secondary coil resistance R 60 (at T = 70C) , 65 (at T = 85C) S A A Ambient operation temperature T 40C ~ +85C A Ambient storage temperature T 40C ~ +90C S 1 2 3 4 5 Maximum current is restricted by V I = 250A Without offset current After removal of core hysteresis Time between 90% input current CC f 6 full scale and 90% of sensor output full scale Without Thermal drift of offset current Electrical Performances Frequency characteristic Saturation characteristic( RM=2 0 ) 3.0 6 2.5 4 2.0 1.5 2 1.0 0 0.5 -2 0.0 -4 -0.5 -1.0 -6 -1.5 -8 T =25C Pulsed A -2.0 -10 -2.5 0.1 1 10 100 -3.0 -250 -200 -150 -100 -50 0 50 100 150 200 250 Frequency characteristic(kHz) Input current (A) If=3AT(Arms) RM=100 S26P200D15YrevC, April 2012 Tamura reserve the right to modify its products in order to improve them without prior notice Attenuation (dB) Output voltage (V)Issued by Module Components Div, TAMURA CORPORATION Hall Effect Current Sensors S26P200D15Y Mechanical dimensions If 48 NOTES 21 1. Unit is mm 10.2 17 2. Tolerance is 0.5mm Terminal number: 1. +Vcc(+15V) 2. I OUT 3. Vcc(-15V) 14 1 3 2 Terminal number 3-(0.6X0.7) Lot No 11.5 12.7 12.7 (25.4) Electrical connection diagram Current S26P200D15Y Voltage output At I = 200A & V = 15V output f CC DC 0 R 56 M -If -If +If +If 3 2 1 3 2 1 -VCC -VCC +VCC +VCC VOUT I OUT RM GND GND UL Standard UL 508 , CSA C22.2 No.14 (UL FILE No.E243511) For use in Pollution Degree 2 Environment. Maximum Surrounding air temperature rating, 85C. CAUTION Do not wrap the primary conductor around the core part of the product to increase measured current. Package & Weight Information Weight Pcs/box Pcs/carton Pcs/pallet 45g 50 200 5400 S26P200D15YrevC, April 2012 Tamura reserve the right to modify its products in order to improve them without prior notice 4.5 33.5 8.4 11 0.5