MCC
GBU8A
omponents
TM
20736 Marilla Street Chatsworth
THRU
Micro Commercial Components
GBU8M
Features
8 Amp Single Phase
Epoxy meets UL 94 V-0 flammability rating
Moisture Sensitivity Level 1
Glass Passivated
Halogen free available upon request by adding suffix-H
Glass Passivated Chip Junction
Bridge Rectifier
High Surge Overload Rating
Lead Free Finish/RoHS Compliant (NOTE 1) Suffix
50 to 1000 Volts
designates RoHS Compliant. See ordering information)
Maximum Ratings
GBU
Operating Temperature: -55C to +150C
Storage Temperature: -55C to +150C
Typical Thermal Resistance 2.2C/W Junction to Case
UL Recognized File # E165989
Mounting Torgue: 5.0 in-lbs Maximum
Maximum Maximum
MCC Device Recurrent Maximum DC
Case Style
Part Number Marking Peak RMS Blocking
3.2x45
A
Reverse Voltage Voltage
C
Voltage
N
N
G
H
GBU8A GBU8A 50V 35V 50V
B
I
GBU8B GBU8B 100V 70V 100V
J
1.90 RADIUS
N N
---- ++
~~~~ ~~~~ ++
GBU8D GBU8D 200V 140V 200V
GBU8G GBU8G 400V 280V 400V
K
D
GBU8J GBU8J 600V 420V 600V
L
GBU8K GBU8K 800V 560V 800V
E
GBU8M GBU8M 1000V 700V 1000V
M
F
DIMENSIONS
Electrical Characteristics @ 25C Unless Otherwise Specified
INCHES MM
Average Forward I 8 A
F(AV) Tc = 100C
DIM MIN MAX MIN MAX NOTE
Current A .860 .880 21.80 22.30
B .720 .740 18.30 18.80
Peak Forward Surge I 200A 8.3ms, half sine
FSM
C .130 .142 3.30 3.60
D .690 .717 17.50 18.20
Current
E .030 .039 0.76 1.00
Maximum
F .018 .024 0.46 0.60
IFM=4A
G .290 .310 7.40 7.90
Instantaneous V 1.0V
F
H .140 .160 3.50 4.10
Forward Voltage T = 25C
J I .065 .085 1.65 2.16
J .060 .096 1.52 2.45
Maximum DC
K .077 .098 1.95 2.50
Reverse Current At I
5 A T = 25C
R J L .040 .050 1.02 1.27
M .190 .210 4.83 5.33
Rated DC Blocking
500uA
T = 125C
J
N 7.0 TYPICAL
Voltage
2
2
2
I t Rating for fusing
(t<8.3ms)
I t 166A S
Typical Junction C 60pF Measured at
J
Capacitance 1.0MHz, V =4.0V
R
Notes: 1. High Temperature Solder Exemption Applied, see EU Directive Annex Notes 7
www.mccsemi.com
1 of 3
Revision: C 2014/03/03MCC
GBU8A thru GBU8M TM
Micro Commercial Components
FIG.1 - FORWARD CURRENT DERATING CURVE
FIG.2 - MAXIMUM NON-REPETITIVE SURGE CURRENT
10.0
WITH HEATSINK
200
8.0
150
6.0
WITHOUT HEATSINK
100
4.0
50
2.0
SINGLE PHASE HALF WAVE 60Hz
Single Half-Sine-Wave
RESISTIVE OR INDUCTIVE LOAD
(JEDEC METHOD)
0
0
0 20 40 60 80 100 120 140 1 2 5 10 20 50 100
CASE TEMPERATURE , C
NUMBER OF CYCLES AT 60Hz
FIG.3 - TYPICAL JUNCTION CAPACITANCE FIG.4 - TYPICAL FORWARD CHARACTERISTICS
1000
100
10
100
TJ = 25 C
10
1.0
PULSE WIDTH 300us
TJ = 25 C, f = 1MHz
1
0.1
1.0 4 10 100
1.4 1.6
0 0.2 0.4 0.6 0.8 1.0 1.2 1.8
REVERSE VOLTAGE , VOLTS
INSTANTANEOUS FORWARD VOLTAGE , VOLTS
FIG.5 - TYPICAL REVERSE CHARACTERISTICS
1000
TJ = 125 C
100
TJ = 100 C
10
TJ = 50 C
1.0
TJ = 25 C
0.1
40 60 80 100
0 20
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
www.mccsemi.com
Revision: C 202 of 3 14/03/03
AVERAGE FORWARD CURRENT
CAPACITANCE , (pF)
AMPERES
INSTANTANEOUS REVERSE CURRENT ,(uA)
PEAK FORWARD SURGE CURRENT,
INSTANTANEOUS FORWARD CURRENT ,(A)
AMPERES