Surge Protection Devices SPD2 1P+1 SERIES Class II/Type 2/Type 1 CA Pluggable Multi-Pole Description Surge protection devices (SPDs) provide equipment protection from overvoltage events lasting micro-seconds. By limiting the overvoltage to the equipment during these events, costly Visual Life equipment damage and downtime can be mitigated. Indicator The surge protection devices for the 1+1 configuration are available for 60 V to 277 V nominal voltage sub-distribution board applications. Features & Benefits Pluggable RC Connector FEATURES BENEFITS Ensures low-residual voltage during high-energy Capability to clamp and surge events and higher nominal discharge current withstand high-energy to prevent disruption, downtime, and degradation or Internal Configuration transients damage to equipment UL Recognized and L N One component can be utilized globally, reducing VDE-IEC compliant in inventory needs and simplifying allocation of parts single part number Interlocking tab Secures module to withstand vibration mechanism TD TD No additional overcurrent protection Reduces the number of components and costs devices required in required for protection UL applications Compact footprint Increases panel design flexibility Quick visual determines module replacement status Visual life indicator RC to avoid loss of protection 14 11 12 Fast and simple to replace, minimizing maintenance Pluggable modules Legend and downtime. No tools required L Line RC Remote Contacts Thermal protection Eliminates catastrophic failure TD Thermal Disconnection N Neutral IP20 protection rating Finger-safe design increases worker protection Protective Earth Module & Base Ordering Information IEC Electrical UL Electrical Ordering Single Unit fi Number Weight 75 V / 20 kA / 50 kA / 800 V / 25 kA / 114 V / 75 V / 330 V / 20 kA / SPD2-075-1P1-R 60 V 100 A 114 V 1200 V 100 kA 124 g (0.274 lb) RMS 305 V 40 kA 65 kA 1500 V 50 kA Withstand 305 V 1000 V 20 kA 150 V / 20 kA / 50 kA / 1250 V / 25 kA / 229 V / 150 V / 600 V / 20 kA / SPD2-150-1P1-R 120 V 100 A 229 V 1200 V 200 kA 128 g (0.283 lb) RMS 305 V 40 kA 65 kA 1500 V 50 kA Withstand 305 V 1000 V 20 kA 300 V / 20 kA / 50 kA / 1500 V / 25 kA / 442 V / 300 V / 900 V / 20 kA / SPD2-300-1P1-R 240 V 100 A 337 V 1200 V 150 kA 135 g (0.298 lb) RMS 305 V 40 kA 65 kA 1500 V 50 kA Safe Fail 305 V 1000 V 20 kA 350 V / 20 kA / 50 kA / 1750 V / 25 kA / 529 V / 350 V / 1000 V / 20 kA / SPD2-350-1P1-R 277 V 100 A 403 V 1200 V 200 kA 140 g (0.309 lb) RMS 305 V 40 kA 65 kA 1500 V 50 kA Safe Fail 305 V 1000 V 20 kA Littelfuse.com/spd 2019 Littelfuse, Inc. 1 of 2 Rev: 1-A-061719 Nominal AC Voltage (50/60Hz) (U /U ) o n Maximum Continuous Operating AC Voltage (L-N / N-PE U ) c Nominal Discharge Current (8/20 s) (L-N / N-PE I ) n Maximum Discharge Current (8/20 s) (L-N / N-PE I ) max Voltage Protection Level (L-N / N-PE U ) p Follow Current Interrupt Rating (N-PE I ) Short-Circuit AC Current Rating (L-N I ) SCCR TOV Withstand 5 s (L-N U ) T TOV 120 min (L-N U ) / Mode T TOV Withstand 200 ms (N-PE U ) T Maximum Continuous AC Operating Voltage (L-N / N-PE MCOV) Voltage Protection Rating (L-N / N-PE VPR) Nominal Discharge Current (8/20 s) (L-N / N-PE I ) n Short-Circuit Current Rating (L-N SCCR)Surge Protection Devices SPD2 1P+1 SERIES Module & Base Part Numbering System Module Only Part Numbering System SPD2 VVV XPZ R SPD2 VVV M Optional Remote Module Only Series Contact Series Maximum Continuous Neutral Maximum Continuous Operating AC Voltage (1=yes or 0=no) Operating AC Voltage Number of Poles Replacement Module Ordering Information IEC Electrical UL Electrical Ordering Single Unit fi Number Weight 40 V / 20 kA / 50 kA / 1500 V 25 kA / 305 V 1000 V 20 kA / SPD2-040-M 0 V 100 A N/A N/A 1200 V N/A 42 g (0.093 lb) RMS 305 V 40 kA 65 kA (N-PE) 50 kA (N-PE) (N-PE) 20 kA 75 V / 20 kA / 50 kA / 800 V / 25 kA / 114 V / 75 V / 330 V / 20 kA / SPD2-075-M 60 V 100 A 114 V 1200 V 100 kA 50 g (0.111 lb) RMS 305 V 40 kA 65 kA 1500 V 50 kA Withstand 305 V 1000 V 20 kA 150 V / 20 kA / 50 kA / 1250 V / 25 kA / 229 V / 150 V / 600 V / 20 kA / SPD2-150-M 120 V 100 A 229 V 1200 V 200 kA 54 g (0.120 lb) RMS 305 V 40 kA 65 kA 1500 V 50 kA Withstand 305 V 1000 V 20 kA 300 V / 20 kA / 50 kA / 1500 V / 25 kA / 442 V / 300 V / 900 V / 20 kA / SPD2-300-M 240 V 100 A 337 V 1200 V 150 kA 61 g (0.135 lb) RMS 305 V 40 kA 65 kA 1500 V 50 kA Safe Fail 305 V 1000 V 20 kA 350 V / 20 kA / 50 kA / 1750 V / 25 kA / 529 V / 350 V / 1000 V / 20 kA / SPD2-350-M 277 V 100 A 403 V 1200 V 200 kA 68 g (0.146 lb) RMS 305 V 40 kA 65 kA 1500 V 50 kA Safe Fail 305 V 1000 V 20 kA Specifications Network Systems IT, TT, TN-S Housing Material Thermoplastic: Extinguishing Degree Mode of Protection L-N, N-PE UL 94 V-0 Nominal Discharge Current Thermal Protection Yes (8/20 s) (L-N / N-PE I ) 20 kA/40 kA Operating State/Fault n Maximum Discharge Current Indication Green Flag/No Green Flag (8/20 s) (L-N / N-PE I ) 50 kA/65 kA Remote Contact Switching max Protective Elements High Energy MOV and GDT Capacity AC: 250 V/1 A, 125 V/1 A Response Time DC: 48 V/0.5 A, 24 V/0.5 A, 12 V/0.5 A (L-N / N-PE t ) < 25 ns Remote Contact Conductor A 2 Back-Up Fuse (max) 315 A / 250 A Gg Cross Section (max) 1.5 mm (16 AWG) (Solid) Number of Ports 1 Standards Passed IEC 61643-11:2011 Mechanical & Environmental EN 61643-11:2012 Operating Temperature UL 1449, 4th edition E320116 Range (T ) -40 C to +80 C (-40 F to +185 F) Product Dimensions a Permissible Operating 2TE Module and Base H 90.0 mm (3.54) W 36.0 mm (1.42) Humidity (RH) 5% to 95% D 70.0 mm (2.76) Altitude (max) 4,000 m (13,123 ft) 1TE Replacement Module H 45.0 mm (1.77) W 18.0 mm (0.71) Terminal Screw Torque) (M ) 4.5 Nm (39.9 lbf-in) D 57.2mm (2.25) max Conductor Cross Section (max) 35 mm (2 AWG) (Solid, Stranded)/ Package Dimensions 2 25 mm (4 AWG) (Flexible) 2TE Module and Base H 102.0 mm (4.01) W 46.0 mm (1.81) Mounting 35 mm DIN Rail, EN60715 D 110.0 mm (4.33) Degree of Protection IP20 (built-in) 1TE Replacement Module H 102.0 mm (4.01) W 28.0 mm (1.10) D 110.0 mm (4.33) Warranty Visit www.littelfuse.com/warranty for details. Disclaimer Notice Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for their own applications. Littelfuse products are not designed for, and may not be used in, all applications. Read complete Disclaimer Notice at www.littelfuse.com/product-disclaimer. Littelfuse.com/spd 2019 Littelfuse, Inc. 2 of 2 Rev: 1-A-061719 Nominal AC Voltage (50/60Hz) (U /U ) o n Maximum Continuous Operating AC Voltage (L-N / N-PE U ) c Nominal Discharge Current (8/20 s) (L-N / N-PE I ) n Maximum Discharge Current (8/20 s) (L-N / N-PE I ) max Voltage Protection Level (L-N / N-PE U ) p Follow Current Interrupt Rating (N-PE I ) Short-Circuit AC Current Rating (L-N I ) SCCR TOV Withstand 5 s (L-N U ) T TOV 120 min (L-N U ) / Mode T TOV Withstand 200 ms (N-PE U ) T Maximum Continuous AC Operating Voltage (L-N / N-PE MCOV) Voltage Protection Rating (L-N / N-PE VPR) Nominal Discharge Current (8/20 s) (L-N / N-PE I ) n Short-Circuit Current Rating (L-N SCCR)