CPC1966B AC Power Switch INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description AC Operating Voltage 20 - 240 V rms CPC1966B is an AC Solid State Switch utilizing Load Current 3 A dual power SCR outputs. This device also includes rms On-State Voltage Drop 0.8 V (at I = 3A ) zero-cross turn-on circuitry and is specified with a rms L rms Blocking Voltage 800 V blocking voltage of 800V . P P In addition, the tightly controlled zero-cross circuitry ensures low noise switching of AC loads by Features minimizing the generation of transients. The optically Load Current up to 3A rms coupled input and output circuits provide 5000V of rms 800V Blocking Voltage P isolation and noise immunity between the control and 5mA Sensitivity load circuits. As a result, the CPC1966B is well suited 5000V Input to Output Isolation rms for industrial environments where electromagnetic Off-State dV/dt: 1000V/s Minimum interference would disrupt the operation of plant facility 12.5mm External Creepage Distance with communication and control systems. Appropriate Layout Zero-Cross Switching Approvals DC Control, AC Output UL 508 Certified Component: File E69938 Optically Isolated CSA Industrial Control Switches Approval: Pending TTL and CMOS Compatible Low EMI and RFI Generation High Noise Immunity Ordering Information Part Description CPC1966B 8-Pin Power SOIC (25/Tube) Applications Programmable Control Process Control Power Control Panels Pin Configuration Remote Switching Gas Pump Electronics AC Load AC Load Contactors 87 6 5 Large Relays Solenoids Motors ZC Heaters 12 3 4 N/C + LED LED N/C DS-CPC1966B-R03 1 www.ixysic.comCPC1966B INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage (V ) 800 V DRM P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1 A 1 Input Power Dissipation 150 mW 2 Total Power Dissipation 2400 mW Isolation Voltage Input to Output 5000 V rms ESD, Human Body Model 8 kV Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 20 mW / C Electrical Characteristics 25C Parameters Conditions Symbol Min Typ Max Units Output Characteristics Load Current, Continuous V =120-240V I 0.1 - 3 A L rms L rms Maximum Surge Current t < 16ms I -- 30 A P P Off State Leakage Current V I - - 100 A DRM LEAK P 1 On-State Voltage Drop I =2A - - 0.88 1.1 V L P P Off-State dV/dt I =0mA dV/dt 1000 - - V/s F Switching Speeds Turn-on t - - 0.5 cycles I = 5 mA on F Turn-off t - - 0.5 cycles off 2 Zero-Cross Turn-On Voltage 1st half cycle - - 5 20 V Subsequent half cycle - - - 5 V Holding Current - I -44 50 mA H Latching Current - I -48 75 mA L Operating Frequency - 20 - 500 Hz Load Power Factor for 3 Guaranteed Turn-On 60Hz PF 0.25 - - - Input Characteristics 4 Input Control Current f=60Hz, I =1A Resistive I -- 5 mA L F Input Drop-out Voltage - - 0.8 - - V Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Input to Output Capacitance - C -- 3 pF I/O 1 Tested at a peak value equivalent. 2 Zero Cross 1st half cycle <100Hz. 3 Snubber circuits may be required at low power factors. 4 For high-noise environments, or for high-frequency operation, use I > 10mA. F R03 2 www.ixysic.com