Data Sheet Flexible RF cable K 02252 D Item: 22510218 Description K: RF cables with PTFE/FEP/PFA dielectrics RG316D/RD316, 50 Ohm, 6 GHz, 200C, 3 mm, FEP jacket Technical Data Construction Material Detail Diameter Centre conductor Steel, Copper+Silver plated Strand-07 0.54 mm Dielectric PTFE (Polytetrafluoroethylene) 1.55 mm Outer conductor Copper, Silver plated Braid, 96% 2 mm Outer conductor Copper, Silver plated Braid, 91 % 2.5 mm Jacket FEP (Fluorinated ethylene propylene) RAL 8015 - br 3 mm +/- 0.1 Print: HUBER+SUHNER K 02252 D 50 Ohm (production order number) Electrical Data Impedance 50 +/- 2 Operating Frequency 6 GHz Capacitance 97 pF/m Velocity of signal propagation 69 % Signal delay 4.86 ns/m Screening effectiveness 80 dB (up to 6 GHz) Operating voltage 0.85 kV (at sea level) rms Test voltage 1.7 kV (50 Hz/1 min) rms Mechanical Data Weight 2.4 kg/100 m Min. bending radius static 18 mm 30 mm dynamic 45 mm Environmental Data Temperature range -65 C ... +200 C Installation temperature -20 C... +60 C Flame propagation test IEC 60332-3, Halogen free No 2011/65/EU (RoHS - including compliant 2015/863 and 2017/2102) 1907/2006/EC (REACH) compliant 2000/53/EC (ELV) compliant 2012/19/EU (WEEE) no special marking needed Additional Information Remarks (For details refer to the HUBER+SUHNER RF CABLES GENERAL CATALOGUE or contact your nearest HUBER+SUHNER partner) Suitable Connectors Cable group U4 2 mm / 50 Ohm Document: DOC-0000177686 AP / PDO L / date of publication: 14.10.2020 17:56:55 / uncontrolled copy Page 1/2Data Sheet Flexible RF cable K 02252 D Item: 22510218 Matrix typical Attenuation formula: (a*f 0.5 + b*f) and maximum Power CW formula: (p/f 0.5) Coefficients: a = 0.7648 b = 0.1301 f = 6 P at 1GHz = 149 max Frequency Nom. attenuation Nom. attenuation Max. CW power (GHz) (dB / m) (dB / ft) (W) sea level 25 C sea level 25 C sea level 40 C ambient ambient ambient temperature temperature temperature 0,3 0,46 0,140 272 0,6 0,67 0,204 192 0,9 0,84 0,257 157 1,2 0,99 0,303 136 1,5 1,13 0,345 122 1,8 1,26 0,384 111 2,1 1,38 0,421 103 2,4 1,5 0,456 96 2,7 1,61 0,490 91 3,0 1,71 0,523 86 3,3 1,82 0,554 82 3,6 1,92 0,585 79 3,9 2,02 0,615 75 4,2 2,11 0,644 73 4,5 2,21 0,673 70 4,8 2,3 0,701 68 5,1 2,39 0,729 66 5,4 2,48 0,756 64 5,7 2,57 0,783 62 6,0 2,65 0,809 61 HUBER+SUHNER is certified according to ISO 9001, ISO 14001, AS/EN9100, ISO/TS 16949 and IRIS. www.hubersuhner.com Waiver: Fact and figures herein are for information only and do not represent any warranty of any kind. Document: DOC-0000177686 AP / PDO L / date of publication: 14.10.2020 17:56:55 / uncontrolled copy Page 2/2