Data Sheet Flexible triaxial cable G 03362-01 Item: 22511961 Description G: RF cables with PE dielectrics Triax (RG58 alternative core), 50 Ohm, 2 GHz, 85C, 7.2 mm, LSFH jacket Technical Data Construction Material Detail Diameter Centre conductor Copper, Tin plated Strand-19 0.9 mm Dielectric PE (Polyethylene) 2.95 mm Outer conductor Copper, Tin plated Braid, 96% 3.6 mm Jacket LSFH (modified polyethylene) RAL 9005 - bk 4.95 mm +/- 0.15 nd Copper, Tin plated Braid, 96 % 5.6 mm 2 Screen Outer Jacket LSFH (modified polyethylene) RAL 9005 - bk 7.2 mm +/- 0.2 Print: HUBER+SUHNER G 03362-01 50 Ohm (production order number) Electrical Data Impedance 50 +/- 2 Operating Frequency 2 GHz Capacitance 101 pF/m Velocity of signal propagation 66 % Signal delay 5 ns/m Operating voltage 2.5 kV (at sea level) rms Test voltage 5 kVrms (50 Hz/1 min) Mechanical Data Weight 9.7 kg/100 m Min. bending radius static 36 mm 75 mm dynamic 110 mm Environmental Data Temperature range -40 C ... +85 C Installation temperature -20 C... +60 C Halogen test IEC 60754 Halogen free Yes 2011/65/EU (RoHS - including compliant 2015/863 and 2017/2102) 1907/2006/EC (REACH) compliant 2000/53/EC (ELV) compliant 2012/19/EU (WEEE) no special marking needed Additional Information Remarks (For details refer to the HUBER+SUHNER RF CABLES GENERAL CATALOGUE or contact your nearest HUBER+SUHNER partner) Suitable Connectors Cable group W2 3 mm / 50+75 Ohm Document: DOC-0000252254 AF / PDO M / date of publication: 14.10.2020 18:02:53 / uncontrolled copy Page 1/2Data Sheet Flexible triaxial cable G 03362-01 Item: 22511961 Matrix typical Attenuation formula: (a*f 0.5 + b*f) and maximum Power CW formula: (p/f 0.5) Coefficients: a = 0.3455 b = 0.2373 f = 2 P at 1GHz = 100 max Frequency Nom. attenuation Nom. attenuation Max. CW power (GHz) (dB / m) (dB / ft) (W) sea level 25 C sea level 25 C sea level 40 C ambient ambient ambient temperature temperature temperature 0,1 0,13 0,041 316 0,2 0,2 0,062 224 0,3 0,26 0,079 183 0,4 0,31 0,096 158 0,5 0,36 0,111 141 0,6 0,41 0,125 129 0,7 0,46 0,139 120 0,8 0,5 0,152 112 0,9 0,54 0,165 105 1,0 0,58 0,178 100 1,1 0,62 0,190 95 1,2 0,66 0,202 91 1,3 0,7 0,214 88 1,4 0,74 0,226 85 1,5 0,78 0,237 82 1,6 0,82 0,249 79 1,7 0,85 0,260 77 1,8 0,89 0,271 75 1,9 0,93 0,283 73 2,0 0,96 0,294 71 HUBER+SUHNER is certified according to ISO 9001, ISO 14001, AS/EN9100, ISO/TS 16949 and IRIS. www.hubersuhner.com Waiver: Fact and figures herein are for information only and do not represent any warranty of any kind. Document: DOC-0000252254 AF / PDO M / date of publication: 14.10.2020 18:02:53 / uncontrolled copy Page 2/2