Data Sheet Coaxial Cable RG 223 /U Description PE-50 Ohm - double screen Technical Data Construction Material Detail Diameter Centre conductor Copper, Silver plated Wire 0.88 mm Dielectric PE (Polyethylene) 2.95 mm Outer conductor Copper, Silver plated Braid, 96% 3.6 mm Outer conductor Copper, Silver plated Braid, 94 % 4.2 mm Jacket PVC II (low migration) RAL 9005 - bk 5.4 mm +/- 0.1 Print: HUBER+SUHNER RG 223 U 50 Ohm (PA no.) Electrical Data Impedance 50 +/- 2 Operating Frequency 6 GHz Capacitance 101 pF/m Velocity of signal propagation 66 % Signal delay 5.03 ns/m Insulation resistance 8 1 x 10 Mm Min. screening effectiveness 85 dB (up to 1 GHz) Max. operating voltage 2.5 kVrms (at sea level) Test voltage 5 kVrms (50 Hz/1 min) Mechanical Data Weight 5.5 kg/100 m Min. bending radius static 30 mm repeated (for bendings) 54 mm Environmental Data Temperature range -25 C... +85 C Installation temperature -20 C... +60 C 2011/65/EU (RoHS) compliant Additional Information Ordering Information Order as RG 223 /U Remarks (For details refer to the HUBER+SUHNER RF CABLES GENERAL CATALOGUE or contact your nearest HUBER+SUHNER partner) Suitable Connectors Cable group U9 3 mm / 50 Ohm Document: DOC-0000177773 AA / PDO M / date of publication: 8/14/2014 2:49:34 PM / uncontrolled copy Page 1/2Data Sheet Coaxial Cable RG 223 /U Matrix typical Attenuation formula: (a*f 0.5 + b*f) and maximum Power CW formula: (p/f 0.5) Coefficients: a = 0.3756 b = 0.0749 f = 6 P at 1GHz = 120 max Frequency Nom. attenuation Nom. attenuation Max. CW power (GHz) (dB / m) (dB / ft) (watt) sea level 25 C sea level 25 C sea level 40 C ambient ambient ambient temperature temperature temperature 0.3 0.23 0.070 219 0.6 0.34 0.102 155 0.9 0.42 0.129 126 1.2 0.5 0.153 110 1.5 0.57 0.174 98 1.8 0.64 0.195 89 2.1 0.7 0.214 83 2.4 0.76 0.232 77 2.7 0.82 0.250 73 3.0 0.88 0.267 69 3.3 0.93 0.283 66 3.6 0.98 0.299 63 3.9 1.03 0.315 61 4.2 1.08 0.330 59 4.5 1.13 0.346 57 4.8 1.18 0.360 55 5.1 1.23 0.375 53 5.4 1.28 0.389 52 5.7 1.32 0.403 50 6.0 1.37 0.417 49 HUBER+SUHNER is certified according to ISO 9001, ISO 14001, ISO/TS 16949 and IRIS www.hubersuhner.com Waiver: It is exclusively in written agreements that we provide our customers with warrants and representations as to the technical specifications and/or the fitness for any particular purpose. The facts and figures contained herein are carefully compiled to the best of our knowledge, but they are intended for general information purposes only. Document: DOC-0000177773 AA / PDO M / date of publication: 8/14/2014 2:49:34 PM / uncontrolled copy Page 2/2