WRB**FWX-O 50 Watt AC/DC Dual Output Universal Input Compact design with Inrush current protection Dual Output -WRB21FWX-O: 5V, 24V - WRB24FWX-O:5V, 12V -WRB22FWX-O: 12V, 12V - WRB25FWX-O:5V, 15V -WRB23FWX-O: 15V, 15V 2 year Warranty RoHS UNIT Voltage/Freq V AC100V - 240V (AC85V ~ 264V or DC125V~ 370V), 50 / 60Hz (47 ~ 440Hz) Universal Input voltage INPUT Current Typ. A 1.2A at 110V .7A at 220V (I =100%) Power Factor - -- Inrush Current A 20A typ (AC IN 110V, I =100%), 40A typ (AC IN 220V, I =100%) at cold start Leakage mA 0.75 UNIT WRB24FWX-O WRB21FWX-O WRB25FWX-O WRB22FWX-O WRB23FWX-O Nominal Voltage VDC 5 12 5 24 5 15 12 12 15 15 OUTPUT Efficiency typ % 75 77 76 77 77 Current A 0.5~5 2 0.5~5 1 0.5~5 1.7 0.1~2.5 1.5 .1~2 1.5 Line Regulation mV (max) 50 120 50 240 50 150 120 120 150 150 Load Regulation mV(max) 100 240 100 480 100 210 240 240 300 300 Ripple mVp-p 80 120 80 150 80 120 120 120 120 120 Ripple Noise mVp-p 120 150 120 250 120 150 150 150 150 150 maximum Temperature Drift mV 75 180 75 360 75 225 180 180 225 225 0-+50C Rise Time mS 1000 max AC IN 110V/220V I =100% Hold up Time mS 17 typ AC IN 110V/220V,I =100% Grounding Individual Ground Over Voltage Works at 115~140% of rating Protection Over Current Works at 105% over rated current and recovers automatically Input-Output AC 3,000V 1 minute current 20mA, DC 500V 100M (At room temperature & Humidity) Isolation Input-F.G AC 2,000V 1 minute current 20mA, DC 500V 100M (At room temperature & Humidity) Output-F.G AC 500V 1 minute current 100mA, DC 500V 100M (At room temperature & Humidity ) Operating temp/hum -10 ~ +70 , 20 ~ 90% RH(Non condensing) Environment Storage temp/hum -20 ~ +75 , 20 ~ 90% RH(Non condensing) Vibration 10 ~ 55Hz at 1G, 3 minutes period, 30 minutes along X, Y and Z axis Impact 10G for 20ms once on each X, Y and Z axis CE/ CB IEC 60950-1, EN60950-1 Safety Line Con RF Voltage EN55022-A MM/G 82 x 35.5 x 135 (150) / 360 Size BLOCK DIAGRAM WRB22FWX-O WRB23FWX-O WRB25FWX-O WRB24FWX-O WRB21FWX-O