ETA-USA The Power Professionals ODM10-SC 10W DC/DC Features 4:1 Wide input range VDC Efficiency 85%~ 88% 5 KVAC Isolation Wide operating temperature from -40C to +105C EMI class A without external circuit No minimum load required Medical safety meets 2xMOPP per 3rd Edition of IEC/EN 60601-1 Low leakage current 5KVAC isolation DIP 24 package Available Inputs Voltage (nominal): 24 VDC Nom (DC9~36V) 48 VDC Nom (DC 1 ~75V) 2 Years Warranty MODEL/CHANNEL Unit ODM10-05SC24 ODM10-12SC24 ODM10-15SC24 ODM10-24SC24 OUTPUT Nominal Voltage V 5 12 15 24 Current A 2.2 .916 .733 .458 Ripple & Noise(pk-pk) mVp-p 30 40 40 50 Efficiency % 85.5 87.5 88 87.5 MODEL/CHANN EL Unit ODM10-05SC48 ODM10-12SC48 ODM10-15SC48 ODM10-24SC48 OUTPUT Nominal Voltage V 5 12 15 24 Current A 2.2 .916 .733 .458 Ripple & Noise(pk-pk) mVp-p 30 40 40 50 Efficiency % 87 89 88 90 Operating Frequency kHz 300 350 Line Regulations mV .02 Load Regulations mV .02 Total Power W 11 ETA-USA 16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 ETA-USA The Power Professionals ODM10 10W DC/DC MODEL/CHANNEL Unit ODM10-SC24 ODM10-SC48 (9~18) (18~36) INPUT Voltage, Frequency V 6 6 Start Up Time mS Nom. Vin at 100% load Typ. 25ms 24VDC Typ. 7.5VDC Voltage Lockout VDC 48VDC Typ. 15VDC 24VDC Max. 50VDC Voltage Surge VDC 48VDC Max. 100VDC 24VDC 9 VDC Start Up Time VDC 48VDC 18 VDC Isolation Voltage Vac 60 sec. 1mA Min. 5KVDC Function Isolation Capacitance pf Max. 15 pF Isolation Resistance - Min. 1000 M Min. 5.6~Max. 8 Min. 13.4~Max. 19.2 Overvoltage Protection - Min. 16.8~Max. 22.5 Min. 26.9~Max. 31.2 Overload Protection - Typ. 150% Environment Cooling Method - Convection Operating temp. & Humidity - -40 ~ +105C Storage temp. & Humidity - -55 ~ +125C MTBF - 25C MIN. 1016 KHrs 24VDC 10 ~ 55Hz at 1G, 3 minutes period, 30 minutes along X, Y and Z axis Vibration - 48VDC Mil-STD 202G IEC68-2-6 10 ~ 55Hz at 1G, 3 minutes period, 30 minutes along X, Y and Z axis EMI EN55011 Class B Radiated immunity EN61000-4-3 Criteria A ESD EN61000-4-2, Air15Kv Contact8kV Criteria A 31.8x20.3x10.2 /13 Fast transient EN61000-4-4, 2kV Criteria A Safety/Emission - Surge EN61000-4-5. 2kV Criteria A Conducted immunity EN61000-4-6 Magnetic field immunity EN61000-4-8 Criteria A Medical safety 2 X MOPP per 3rd edition of IEC/EN 60601 Dimension Size(LxWxH) 24VDC 25.4 25.4x10/17 mm/g /Weight 48VDC 50.8x25.4x12/30 Case Material - PLASTIC MATERIAL Potting Material ETA-USA 16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037