2200 SERIES REED RELAYS
2200 Series Reed Relays
Ideally suited to the needs of Automated Test Equipment and RF requirements Th . e
specicfi ation tables allow you to select the appropriate relay for your particular ap -
plication . If your requirements differ, please consult your local representative or Cotos
Factory .
2200 Series Features
2
u
Very small footprint (0 . 17 in ), high reliability reed relays
12
u
High Insulation Resistance - 10 available with model 2204
u
High speed switching compared to electromechanical relays
u
Hermetically sealed contacts for long life
u
Epoxy coated steel shell provides magnetic shielding
u
Optional Electrostatic Shield for reducing capacitive coupling
u
Optional Coaxial Shield for 50 impedance and switching of fast rise time digital
pulses offered on Form A
u
Relay models 2200-2301, 2200-2302 are ATE industry standards
u
Specicfi ally engineered for OEM designs and maintenance of existing
production fixtures
u
RoHS compliant
DIMENSIONS
in Inches (Millimeters)
.810 .210
(20.57)
(5.33)
.225 (5.72)
.020
.500
(0.51)
(12.7)
.100
.125
(2.54)
(3.18)
.700
.018 Dia. pins
(17.78)
(0.46)
4
1 2 3
5
867
Bottom View
Ordering Information
XXXX-XX-XX1
Part Number
2
Model Number Shielding Options
NOTE
2204 0=No Shielding
u Coil Voltage
Model #s 2200-2301 & 2200-2302 represent
2211 1=Electrostatic Shield
complete part numbers . 05=5 volts
Coil Options
(N/A on Model #2211)
12=12 volts
3=use for Model #2204 (12 volt coil)
2=Coaxial Shield
and Model #2211 (5 & 12 volt coil)
(N/A on Model #2211)
4=use for Model #2204 (5 volt coil)
tel: (401) 943.2686 | fax: (401) 942.0920
12 | page2200- 2200-
2204 2211
MODEL NUMBER
2301 2302
Parameters Test Conditions Units 1 Form A 1 Form C 1 Form A 1 Form A
Electrostatic Coaxial Shield
Shield
COIL SPECS.
Nom. Coil Voltage VDC 5 12 5 12 5 5
Coil Resistance +/- 10%, 25 C 370 1500 230 1500 150 150
Operate Voltage Must Operate by VDC - Max. 3. 8 9.0 3.8 9.0 3.6 3.6
Release Voltage Must Release by VDC - Min. 0.4 1.0 0.4 1.0 0.5 0.5
CONTACT RATINGS
Switching Voltage Max DC/Peak AC Resist. Volts 200 100 150 150
Switching Current Max DC/Peak AC Resist. Amps 0.5 0.25 0.5 0.5
Carry Current Max DC/Peak AC Resist. Amps 1.0 0.5 1.0 1.0
Contact Rating Max DC/Peak AC Resist. Watts 10 3 10 10
1 6
Life Expectancy-Typical Signal Level 1.0V, 10mA x 10 Ops. 500 100 500 500
6
Rated Loads x 10 Ops. 5 5 5 5
Static Contact
50mV, 10mA 0.100 0.150 0.150 0.150
Resistance (max. init.)
Dynamic Contact 0.5V, 50mA
0.200 0.200 0.200 0.200
Resistance (max. init.) at 100 Hz, 1.5 msec
RELAY SPECIFICATIONS
Insulation Resistance Between all Isolated Pins
12 11 11 11
10 10 10 10
(minimum) at 100V, 25C, 40% RH
Capacitance - Typical Shield Floating pF 0.9 0.9 0.9 0.9
Across Open Contacts Shield Guarding pF 0.2 N/A 0.2 0.2
Between Contacts VDC /peak AC 250 200 250 250
Dielectric Strength
Contacts to Coil VDC/peak AC 250 N/A 250 250
(minimum)
Contacts/Shield to Coil VDC/peak AC 1500 1500 1500 1500
Operate Time - At Nominal Coil Voltage,
msec. 0.5 (typ.) 1.0 (typ.) 0.55 (max.) 0.55 (max.)
including bounce 30 Hz Square Wave
Release Time - Typical msec. 0.1 2.0 0.1 0.1
To p V i e w : 5 4 5 4
5 4 5 4
Dot stamped on top of relay refers to pin #1 location 6 3 6 3 6 3
6 3
Grid = .1x.1 (2.54mm x 2.54mm)
7 2
7 2
7 2 7 2
8 1
8 1
8 1
8 1
Notes:
1
Consult factory for life expectancy at other switching loads .
2
Model 2204, pin #7 is tied to optional electrostatic shield, pins #6 & #7 are tied to optional coaxial shield .
Environmental Ratings:
+ +
Storage Temp: -35C to 100C; Operating Temp: -20C to 85C; Solder Temp: 270C max; 10 sec . max
All electrical parameters measured at 25C unless otherwise specified .
Vibration: 20 Gs to 2000 Hz; Shock: 50 Gs
COTO TECHNOLOGY, INC.