5456SafetyCatalog.qk 9/26/04 9:03 PM Page 20 Emergency Stop and Safety Gate Modules NA1/3-D, NA1/3-D/230 Safety Category 4 according to EN 954-1 Category 0 Emergency Stop 3 NO safety outputs 24 VAC / VDC, 110 or 230 VAC power supply single/dual channel automatic or manual reset self monitoring Failure diagnosis by LEDs Approvals: Product Description Ordering Key NA1/3-D/230 Emergency Stop and Safety includes 24 Vac/Vdc, 110 or Case Gate modules according to 230 Vac. Application EN 60204-1, EN 292-1/-2, Every model is characterized Controlled Devices EN 418 and EN 1088. by dual channel input and Safety Outputs This family of safety module safety output contacts with Safety Category in Safety Category 4, force guided relay outputs. Power Supply Type Selection Power supply References 24 VAC/VDC NA1/3-D 110 VAC NA1/3-D/110 230 VAC NA1/3-D/230 Electrical Specifications Power supply Switching voltage / NA1/3-D 24 Vac/dc 10% current /capability NA1/3-D/110 110 Vac 10% NA1/3-D 24 Vdc / 5A NA1/3-D 230 230 Vac 10% NA1/3-D/110 110 Vac / 5A Power consumption 3 VA / 3 W NA1/3-D 230 230 Vac / 5A Input current/voltage 0.9 to 1.1 V Contact fuse protection 5 A fast or 4 A slow Safety outputs 3 NO Insulation voltage Pollution degree: 2. Overvoltage Category: Auxiliary outputs 1 NC 3 / 250 V Basis insulation: Overvoltage Category: 3 / 250 V Time Specifications Environmental Specifications Delay on energisation - Operating temperature -25C to + 55C Delay on de-energisation < 30 ms Storage temperature -25C to + 65C Channel simultaneity Mechanical Specifications 2 Protection degree terminals IP 20 Max cross section 2.5 mm rigid wire 2 of external conductors 2.5 mm flexible wire Protection degree housing IP 40 Dimensions (H x W x D) 22.5 x 114.5 x 99 mm Housing material Polyamid PA6.6 Weight Housing type 22.5 mm housing models NA1/3-D 170 g Mounting DIN rail NA1/3-D/110 238 g NA1/3-D 230 238 g 1-17 Specifications are subject to change without notice (10.01.04)5456SafetyCatalog.qk 9/26/04 9:03 PM Page 21 NA1/3-D, NA1/3-D/230 Dimensions 99 22,5 114,5 Wiring Diagrams Application Dual Channel Emergency Stop POWER A1 A2 S33 S34 S11 S12 S21 S22 13 23 33 41 SUPPLY E-STOP Trasf. K2 START Control Logic AC K1 DC K1 K2 S33 S34 A1 A2 S21 S22 S11 S12 13 23 33 41 - + (+) (-) 14 24 34 42 14 24 34 42 Connection Sample Connections Terminal Function Connection A1 +24 Vdc or AC supply A2 GND or AC supply S11-S12 First input channel (E-STOP or Safety Switch Channel 1) 13 23 33 41 13 23 33 41 S21-S22 Second input channel A1 S34S33S12 A1 S34S33S12 (E-STOP or Safety Switch Channel 2) NA1/3-D NA1/3-D/230 Power Power S33-S34 START (automatic o manual) Channel 2 Channel 2 13-14 First safety output (N.O.) 23-24 Second safety output (N.O.) Channel 1 Channel 1 13 23 33 41 13 23 33 41 33-34 Third safety output (N.O.) 14 24 34 42 14 24 34 42 41-42 Auxiliary output (N.C.) S21S22S11 A2 S21S22S11 A2 14 24 34 42 14 24 34 42 NA1/3-D/110 or 230 NA1/3-D Specifications are subject to change without notice (10.01.04) 1-18