The MCC750 Series of AC-DC power supplies provides a steady 750 W of regulated DC power through 180-305 VAC and 600 W through 85-137 VAC input voltage ranges in a single output of 24 or 48 VDC. The natural convection cooling operation (without fan), is particularly suitable for environments sensitive to acoustical noise. The MCC750 Series comes in two U-shaped 1.6 high packages, with and without a protective cover, offering 12 and 5 VSB standby outputs and a full set of protection features. The MCC750 Series supports digital power management over the Power Management Bus communications protocol. Multiple units may be connected in parallel for redundancy and / or higher power, enabled with the internal OR-ing and current sharing functions. The MCC750 Series complies with the latest edition of the IEC/EN 60601- 1 safety standards for medical equipment requiring 2x MoPP protection grade and displays the CE-Mark for the European Low Voltage Directive (LVD). Universal input voltage range 90 305 V , MoOP 90 264 V , MoPP AC AC Input inrush current limiting 750 W rated power (900 W peak for <10 s) High efficiency up to 94% Single 24 VDC or 48 VDC output voltages available Active PFC, EN61000-3-2 compliant (Class C, >25% load) Low earth / touch leakage current Natural convection cooling Over temperature, OV, OC and SC protections +12 V / 0.3 A +5 V / 0.72 A Stand by outputs Built-in current sharing and OR-ing for parallel operation and N+1 redundancy Power good and remote sense signals Remote On / Off signal Power Management Bus communication protocol supported Medical safety approval to IEC 60601-1 3rd edition, 2x MoPP rated and BF appliances compatible IEC 60601-1-2 4th edition EMC compliant RoHS 3 compliant (Directive EU 2015/863) X-Ray / CT Scanner Dental Equipment Laboratory / Analysis Equipment Medical Devices / Applications 2 MCC750 Series INPUT NOM. MAX. MAX. VOLTAGE OUTPUT OUTPUT OUTPUT MODEL NUMBER PACKAGE & COOLING DIMENSIONS RANGE VOLTAGE POWER CURRENT VAC VDC W A U-chassis 101.6 x 234.0 x 41.0 mm MCC750-1T24 85 - 305 24 750 31.2 Natural Convection 4.00 x 9.21 x 1.61 in U-chassis 101.6 x 234.0 x 41.0 mm MCC750-1T48 85 - 305 48 750 15.6 Natural Convection 4.00 x 9.21 x 1.61 in U-chassis + Protective Cover 101.6 x 234.7 x 41.0 mm MCC750-1T24-PC 85 - 305 24 750 31.2 Natural Convection 4.00 x 9.24 x 1.61 in U-chassis + Protective Cover 101.6 x 234.7 x 41.0 mm MCC750-1T48-PC 85 - 305 48 750 15.6 Natural Convection 4.00 x 9.24 x 1.61 in PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT PS starts at 85 VAC at all load conditions Operating input voltage range 85 100-277 305 VRMS AC Input Voltage MCC750 Series is designed to operate with a square or trapezoidal input voltage wave form (i.e. from UPS) Built in fuses safety certified up to 250 VDC. Operating the MCC750 above DC Input Voltage 120 - 300 V DC that limit up to 300 VDC, does require an external fuse protection * Input Frequency 47 50/60 63 Hz At 180 V , 750 W, 50 / 60 Hz 5.0 AC ARMS At 85 V , 600 W load, 50 / 60 Hz 8.7 AC Input Current - - 163 VDC, maximum load 5.6 A 120 VDC, 650 W 6.0 At power-on asserted Cold start, 25 C ambient, full load Inrush Current Any point of the AC input sine 230 VAC - - 30 A 277 VAC - - 50 Fusing High breaking, 16 / 20 A, 277 V (250 V ) on each AC line. - - 16 / 20 A AC DC 20% rated load 85 - - At 120 VAC 50% rated load 92 - - 100% rated load 92 - - Efficiency % 20% rated load 87 - - At 230 VAC 50% rated load 93 - - 100% rated load 94 - - At power on, no load, 100 277 VAC range - 6.0 - Input Power Consumption W Stand by, no load, nominal 100 277 V range - 3.5 - AC Power Factor Any nominal input line voltage, 50/60 Hz, from 50 to 100% maximum load 0.95 - - - THDi From 50 to 100% rated load, 100 277 V , 50/60 Hz. - - 20 % AC Complies with EN 61000-3-2 at 230 V , 50/60 Hz, Class A, D. AC Harmonic Current Complies with EN 61000-3-2 Class C at 230 V , 50/60 Hz, >300 W load. AC Fluctuations and Flicker Complies with EN 61000-3-3 at nominal voltages and full load. Normal conditions 115 VRMS, 60 Hz - 170 - Earth Leakage Current A 230 V , 50 Hz - 300 - RMS 264 V , 60 Hz (worst case) - - 450 RMS 264 VRMS, 60 Hz Touch Leakage Current Normal Condition (NC) - - 100 A Single Fault Condition (SFC) - - 500 264 VRMS, 60 Hz Patient Leakage Current Normal Condition (NC) - - 100 A Single Fault Condition (SFC) - - 500 * Suggested fuse SIBA 5012434.16 and fuse holder SIBA 5105805.1 tech.support psbel.com