The MBS601 Series of AC-DC power supplies provides up to 600 W of regulated output power through a wide input voltage range 85 264 VAC in a single output of 24 VDC or 48 VDC. The MBS601 Series comes in a 4.92 x 9.86 x 2.36 inch form factor with a full set of protection features. The MBS601 Series is available in an aluminium extruded chassis having fins for an optimal heat dispersion via natural convection. The input / output connections are fixed to the chassis through water tight glands, which combined with the sealed enclosure, give the power supply an IP66/67/68 ingress protection grade. The -SL option offers a 5 VDC stand-by output and a set of control signals: +/- remote sense, remote On/Off (-PS Inhibit), power good (PS Ok), I-share (ISHARE1+V SLOGIC). The MBS601 Series complies with the latest edition of the IEC/EN 60601-1 safety standards for medical equipment requiring 2x MoPP protection grade and displays the CE Mark for the European Low Voltage Directive (LVD). Sealed enclosure, IP66/67/68 Ingress Protection grade High efficiency up to 94% (50% to 100% load) Low stand-by power consumption (< 0.35 W) Universal input voltage range 85 264 VAC Input inrush current limiting <30 A 800 W peak power (up to 10 s) Single 24, 48 VDC voltages Active PFC, EN61000-3-2 compliant (Class C, >25% load) Low earth / touch leakage current Over temperature, OV, OC and SC protections. Stand by +5 V, 1.5 A output. Remote On / Off signal Overall dimensions 125.0 x 250.5 x 60.0 mm (4.92 x 9.86 x 2.36 in) Medical safety approval to IEC 60601-1 3rd edition, 2xMoPP protection grade BF appliances compatible IEC 60601-1-2 4th edition EMC compliant Clinical Analysers Dental units / chairs MRI / Full Body TC Systems Medical Diagnostic & Imaging Systems 2 MBS601 Series INPUT VOLTAGE NOM. OUTPUT MAX. OUTPUT MAX. OUTPUT MODEL NUMBER PACKAGE & COOLING RANGE VOLTAGE POWER CURRENT DIMENSIONS VAC VDC W A Sealed Chassis MBS601-1T24 85 - 305 24 600 25 Natural Convection Sealed Chassis MBS601-1T24-SL Natural Convection 85 - 305 24 600 25 + Control Signals 125.0 x 250.5 x 60.0 mm Sealed Chassis 4.92 x 9.86 x 2.36 in MBS601-1T48 85 - 305 48 600 12.5 Natural Convection Sealed Chassis MBS601-1T48-SL Natural Convection 85 - 305 48 600 12.5 + Control Signals PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT MoPP grade 85 100-240 264 VRMS MoOP grade 85 100-277 305 AC Input Voltage PS starts and operates at 85 V at all load conditions AC Built in fuses has been safety certified up to 250 VDC. DC Input Voltage Operating the MBS601 above that limit up to 300 V does require an 170 - 300 V DC DC external fuse protection. 440 Hz with reduced PFC and output power rating. Input Frequency 47 50/60 63 Hz Consult factory for details. RMS at 180 V , maximum load, 50 / 60 Hz 4.0 AC Input Current - - A RMS at 85 VAC, maximum load, 50 / 60 Hz 8.5 Cold start, 25 C ambient, full load Inrush Current 115 V - - 20 AC A 230 V - - 30 AC Fusing High breaking, 10 A, 250 V on each AC lines. - - 10 A 20% rated load 89 - - At 115 V 50% rated load 93 - - AC 100% rated load 92 - - Efficiency % 20% rated load 90 - - At 230 / 264 V 50% rated load 94 - - AC 100% rated load 94 - - Power on, 115 VAC, no load - - 5 Input Power Consumption Power on, 230 VAC, no load - - 4 W Stand by, 115, 230 V , no load - - 0.35 AC Power Factor From 50 to 100% of rated load, 230, 115 VAC, 50 / 60 Hz input voltages. 0.90 - - - THDi From 50 to 100% rated load, 115, 230, 264 V 50 / 60 Hz. - - 20 % AC Complies with EN 61000-3-2 at 230 VAC, 50/60 Hz, Class A, D. Harmonic Current Complies with EN 61000-3-2 Class C at 230 V , 50/60 Hz, >150 W load. AC Fluctuations and Flicker Complies with EN 61000-3-3 at nominal voltages and full load. Normal conditions 115 VRMS, 60 Hz - 170 - Earth Leakage Current 230 V , 50 Hz - 290 - A RMS 264 V , 60 Hz (worst case) - - 460 RMS tech.support psbel.com