Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9455 Multi-Conductor - Audio, Control and Instrumentation Cable For more Information please call 1-800-Belden1 General Description: 20 AWG stranded (7x28) tinned copper conductors, conductors cabled, PVC insulation, PVC jacket. Physical Characteristics (Overall) Conductor AWG: Conductors AWG Stranding Conductor Material 9 20 7x28 TC - Tinned Copper Total Number of Conductors: 9 Insulation Insulation Material: Insulation Material Wall Thickness (in.) PVC - Polyvinyl Chloride 0.015 Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (in.) PVC - Polyvinyl Chloride .035 Overall Cable Overall Cabling Color Code Chart: Number Color 1 White 2 Red 3 Green 4 Brown 5 Blue 6 Orange 7 Yellow 8 Purple (around Black) 9 Black Overall Nominal Diameter: 0.317 in. Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +80C UL Temperature Rating: 80C (UL AWM Style 2464) Bulk Cable Weight: 63 lbs/1000 ft. Max. Recommended Pulling Tension: 111 lbs. Min. Bend Radius/Minor Axis: 3.250 in. Page 1 of 3 11-08-2019Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9455 Multi-Conductor - Audio, Control and Instrumentation Cable Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMG CEC/C(UL) Specification: CMG AWM Specification: UL Style 2464 (300 V 80C) EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes Flame Test UL Flame Test: UL1685 FT4 Loading CSA Flame Test: FT4 Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Capacitance Conductor to Conductor: Capacitance (pF/ft) 27 Nom. Conductor DC Resistance: DCR 20C (Ohm/1000 ft) 10.7 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 2.8 Amps per conductor 25C Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc 9455 060100 100 FT 6.400 LB CHROME 9 20 PVC FRPVC 9455 0601000 1,000 FT 64.000 LB CHROME C 9 20 PVC FRPVC 9455 060500 500 FT 33.500 LB CHROME C 9 20 PVC FRPVC 9455 0605000 5,000 FT 325.000 LB CHROME C 9 20 PVC FRPVC Notes: C = CRATE REEL PUT-UP. Revision Number: 3 Revision Date: 09-11-2012 2019 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Page 2 of 3 11-08-2019