Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9533 Multi-Conductor - Computer Cable for EIA RS-232 Applications For more Information please call 1-800-Belden1 Description: 24 AWG stranded (7x32) tinned copper conductors, conductors cabled, PVC insulation, overall Beldfoil shield (100% coverage), 24 AWG stranded tinned copper drain wire, PVC jacket. Physical Characteristics (Overall) Conductor AWG: Conductors AWG Stranding Conductor Material 3 24 7x32 TC - Tinned Copper Insulation Insulation Material: Insulation Material Wall Thickness (in.) PVC - Polyvinyl Chloride .010 Outer Shield Outer Shield Material: Outer Shield Trade Name Outer Shield Material Coverage (%) Beldfoil Aluminum Foil-Polyester Tape 100 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 24 7x32 TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Nom. Wall Thickness (in.) Beldfoil PVC - Polyvinyl Chloride .032 Overall Cable Overall Cabling Lay Length & Direction: Length (in.) 1.50 Overall Cabling Color Code Chart: Number Color 1 Black 2 White 3 Red Overall Nominal Diameter: 0.162 in. Mechanical Characteristics (Overall) Operating Temperature Range: -30C To +80C UL Temperature Rating: 80C (UL AWM Style 2464) Bulk Cable Weight: 16 lbs/1000 ft. Max. Recommended Pulling Tension: 16.500 lbs. Min. Bend Radius (Install)/Minor Axis: 1.750 in. Page 1 of 3 05-09-2012Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9533 Multi-Conductor - Computer Cable for EIA RS-232 Applications Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMG CEC/C(UL) Specification: CMG AWM Specification: UL Style 2464 (300 V 80C) EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes Flame Test C(UL) Flame Test: FT4 Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Capacitance Conductor to Conductor: Capacitance (pF/ft) 33 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/ft) 65 Nom. Conductor DC Resistance: DCR 20C (Ohm/1000 ft) 25 Nominal Outer Shield DC Resistance: DCR 20C (Ohm/1000 ft) 18 Max. Operating Voltage - UL: Voltage 300 V RMS (UL AWM Style 2464) Max. Recommended Current: Current 1.75 Amps per conductor 25C Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc 9533 060U1000 1,000 FT 18.000 LB CHROME 3 24 PVC FS PVC 9533 060U500 500 FT 9.500 LB CHROME 3 24 PVC FS PVC 9533 060100 100 FT 2.400 LB CHROME 3 24 PVC FS PVC 9533 0601000 1,000 FT 18.000 LB CHROME C 3 24 PVC FS PVC 9533 060500 500 FT 9.000 LB CHROME 3 24 PVC FS PVC 9533 0605000 5,000 FT 85.000 LB CHROME 3 24 PVC FS PVC Notes: C = CRATE REEL PUT-UP. Page 2 of 3 05-09-2012