Product: 9265 Composite ENG, EFP and CCTV Product Description Composite, RG-59 22 AWG BC Coax, stranded (7x30), BC braid 95% coverage, 1 PR 22 AWG TC, stranded (7x30), w/drain wire, PVC jacket. Technical Specifications Physical Characteristics (Overall) Conductor AWG Stranding Material Nominal Diameter No. of Pairs No. of Coax 22 Stranded BC - Bare Copper 0.03 in 1 22 TC - Tinned Copper 0.03 in 1 Total Number of Pairs: 1 Insulation Material Nominal Diameter PE - Polyethylene (Foam) 0.146 in PVC - Polyvinyl Chloride 0.054 in Color Chart Number Color 1 Black 2 Red Inner Shield Material Type Material Material Trade Name Coverage % Drainwire Material Drainwire Diameter Drainwire AWG Drainwire Construction n x D Braid Bare Copper (BC) 95% TC - Tinned Copper 0.03 in 22 7x30 Bi-Laminate Tape Beldfoil (Z-Fold) 100% (Alum+Poly) Outer Jacket Material Material Nominal Diameter PVC - Polyvinyl Chloride 0.47 in Electrical Characteristics Conductor DCR Nominal Conductor DCR Conductor Resistance Nominal Inner Shield DCR Nominal Outer Shield DCR 15 Ohm/1000ft 2.6 Ohm/1000ft 11 Ohm/1000ft Capacitance Element Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Shield Coax 51 pF/ft 17.3 pF/ft Pair 95.5 pF/ft Inductance Nominal Inductance 0.09 H/ftImpedance Element Nominal Characteristic Impedance Coax 75 Ohm High Frequency (Nominal/Typical) Element Frequency MHz Nom. Insertion Loss Coax 1 MHz 0.3 dB/100ft 5 MHz 0.7 dB/100ft 10 MHz 1 dB/100ft 50 MHz 2.1 dB/100ft 100 MHz 3 dB/100ft Delay Element Nominal Delay Coax 1.3 ns/ft Voltage UL Voltage Rating 30 V RMS Electrical Characteristics Notes: Coax Nominal Voltage Breakdown Jacket (Shield to Ground) = 22kV RMS Temperature Range Non-UL Temp Rating: 60C Operating Temp Range: -40C To +60C Mechanical Characteristics Bulk Cable Weight: 58 lbs/1000ft Max. Pull Tension: 68 lbs Min Bend Radius/Minor Axis: 2.5 in Standards NEC/(UL) Compliance: CL2 UL AWM Style Compliance: UL Style 20006 RG Type: 59/U Type Applicable Environmental and Other Programs Environmental Space: Indoor (Not Riser or Plenum) EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/11/EC (BFR): Yes EU Directive 2011/65/EU (ROHS II): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU: Yes EU Directive Compliance: Yes EU CE Mark: No EU RoHS Compliance Date (yyyy-mm-dd): 2005-04-01 MII Order 39 (China RoHS): Yes Suitability Suitability - Indoor: Yes Flammability, LS0H, Toxicity Testing UL Flammability: UL1685 UL Loading UL voltage rating: 30 V RMS Plenum/Non-Plenum Plenum (Y/N): No Part Number Variants