Product: 9064 CATV Video, RG11, 14 AWG BCCS Tri Shield, CM PVC Jacket Product Description CATV, Series 11, 14 AWG solid .064 bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond Plus aluminum braid shield (76% coverage), CM PVC jacket. Technical Specifications Physical Characteristics (Overall) Conductor AWG Stranding Material Nominal Diameter No. of Coax 14 Solid BCCS - Bare Copper Covered Steel 0.064 in 1 Conductor Count: 1 Insulation Material Nominal Diameter PE - Polyethylene (Foam) 0.28 in Table Notes: Gas Injected Outer Shield Material Type Layer Material Material Trade Name Coverage % Tape 1 Alum / Poly / Alum Duobond II 100% Braid 2 Aluminum 77% Tape 3 Alum / Poly 100% Table Notes: Tape has shorting fold and is bonded to jacket Outer Jacket Material Material Nominal Diameter PVC - Polyvinyl Chloride 0.393 in Electrical Characteristics Conductor DCR Nominal Conductor DCR Nominal Outer Shield DCR Outer Conductor DCR 11 Ohm/1000ft 3.8 Ohm/1000ft 3.8 Ohm/1000ft Capacitance Nom. Capacitance Conductor to Shield 16.2 pF/ft Inductance Nominal Inductance 0.097 H/ft Impedance Nominal Characteristic Impedance Nominal Characteristic Tolerance 75 Ohm 3 OhmReturn Loss (RL) Frequency MHz Min. Structural Return Loss (SRL) 5-1000 MHz 20 dB Delay Nominal Delay Nominal Velocity of Propagation (VP) % 1.2 ns/ft 83% High Freq Frequency MHz Max. Insertion Loss (Attenuation) 5 MHz 0.38 dB/100ft 55 MHz 0.96 dB/100ft 211 MHz 1.9 dB/100ft 270 MHz 2.13 dB/100ft 300 MHz 2.25 dB/100ft 350 MHz 2.42 dB/100ft 400 MHz 2.6 dB/100ft 450 MHz 2.75 dB/100ft 550 MHz 3.04 dB/100ft 750 MHz 3.65 dB/100ft 870 MHz 4.06 dB/100ft 1000 MHz 4.35 dB/100ft Voltage Non-UL Voltage Rating 300 V RMS Temperature Range Non-UL Temp Rating: 80C Operating Temp Range: -40C To +80C Mechanical Characteristics Bulk Cable Weight: 55 lbs/1000ft Max. Pull Tension: 276 lbs Min Bend Radius/Minor Axis: 4 in Standards NEC/(UL) Compliance: CATV, CM CEC/C(UL) Compliance: CM CPR Euroclass: Eca RG Type: 11/U Type Series Type: 11 Applicable Environmental and Other Programs Environmental Space: Indoor (Not Riser or Plenum) EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/96/EC (BFR): Yes EU Directive 2011/65/EU (ROHS II): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU: Yes EU Directive Compliance: EU Directive 2003/11/EC (BFR) EU CE Mark: Yes EU RoHS Compliance Date (yyyy-mm-dd): 2004-01-01 MII Order 39 (China RoHS): Yes Suitability Suitability - Indoor: Yes Flammability, LS0H, Toxicity Testing UL Flammability: UL1685 UL Loading