Product: 735A1T DS-3 and DS-4, 735A Series, 26 AWG SPC Coax, Siamese Tracer, CMR/CMG Product Description 735A Series, 26 AWG Solid .016 (.40mm) silver-plated copper conductor(s), foam HDPE insulation, Beldfoil + tinned copper braid shield (95% coverage), CMR rated, PVC jacket. PVC insulated tracer wire in Siamese (Figure 8) configuration. Technical Specifications Physical Characteristics (Overall) Conductor AWG Stranding Material Nominal Diameter No. of Coax 26 Solid SC - Silvered Copper 0.016 in 1 Conductor Count: 2 Insulation Material Nominal Diameter PE - Polyethylene (Foam) 0.077 in Outer Shield Type Layer Material Material Trade Name Coverage % Tape 1 Bi-Laminate (Alum+Poly) Beldfoil 100% Braid 2 Tinned Copper (TC) 95% Outer Jacket Material Nominal Diameter PVC - Polyvinyl Chloride 0.129 x 0.203 in Electrical Characteristics Conductor DCR Nominal Conductor DCR Nominal Outer Shield DCR Outer Conductor DCR 41 Ohm/1000ft 5.3 Ohm/1000ft 7 Ohm/1000ft Capacitance Nom. Capacitance Conductor to Shield 17.7 pF/ft Inductance Nominal Inductance 0.19 H/ft Impedance Nominal Characteristic Impedance 75 Ohm Return Loss (RL) Frequency MHz Minimum Return (RL) 15-95 MHz 30 dBDelay Nominal Delay Nominal Velocity of Propagation (VP) % 1.34 ns/ft 76% High Frequency Frequency MHz Max. Insertion Loss (Attenuation) Min. RL (Return Loss) dB 1 MHz 0.6 dB/100ft 30 dB 1.024 MHz 0.61 dB/100ft 4.224 MHz 1.1 dB/100ft 5 MHz 1.2 dB/100ft 10 MHz 1.7 dB/100ft 17.184 MHz 2.2 dB/100ft 22.368 MHz 2.5 dB/100ft 25.92 MHz 2.7 dB/100ft 44.736 MHz 3.6 dB/100ft 50 MHz 3.8 dB/100ft 69.632 MHz 4.5 dB/100ft 77.76 MHz 4.8 dB/100ft 100 MHz 5.5 dB/100ft 137.088 MHz 6.4 dB/100ft 200 MHz 7.8 dB/100ft Voltage UL Voltage Rating 300 V RMS Electrical Characteristics Notes: Return Loss: Fixed bridge and termination Temperature Range Operating Temp Range: -20C To +75C Mechanical Characteristics Bulk Cable Weight: 13 lbs/1000ft Max. Pull Tension: 25 lbs Min. Bend Radius/Minor Axis: 1.3 in Standards NEC/(UL) Compliance: CMR CEC/C(UL) Compliance: CMG RG Type: Sub-miniature 59 Other Specification: Telcordia Specification GR-139-CORE. Applicable Environmental and Other Programs Environmental Space: Indoor - Riser EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/11/EC (BFR): Yes EU Directive 2011/65/EU (RoHS 2): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU (RoHS 2 amendment): Yes EU Directive Compliance: EU Directive 2003/11/EC (BFR) MII Order 39 (China RoHS): Yes Suitability Suitability - Indoor: Yes Flammability, LS0H, Toxicity Testing UL Flammability: UL1666 Vertical Shaft CSA Flammability: FT4 UL voltage rating: 300 V RMS Plenum/Non-Plenum