Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 123092A Coax - ControlNet Quad Shielded Coax For more Information please call 1-800-Belden1 General Description: 18 AWG solid bare copper-covered steel conductor, foam polyethylene insulation, Duobond IV quad shield (100% coverage), PVC inner jacket, aluminum interlocked armor, PVC sunlight-resistant outer jacket. Usage (Overall) Suitable Applications: ControlNet, Modbus II, Industrial Coax Physical Characteristics (Overall) Conductor AWG: Coax AWG Stranding Conductor Material Dia. (in.) 1 18 Solid BCCS - Bare Copper Covered Steel .040 Total Number of Conductors: 1 Insulation Insulation Material: Insulation Material Dia. (in.) FPE - Foam Polyethylene .180 Inner Jacket Inner Jacket Material: Inner Jacket Material Nom. Dia. (in.) PVC - Polyvinyl Chloride 0.298 Outer Shield Outer Shield Material: Layer Outer Shield Trade Name Type Outer Shield Material Coverage (%) 1 Bonded Duofoil Tape Bonded Aluminum Foil-Polyester Tape-Aluminum Foil 100 2 Braid AL - Aluminum 60 3 Duofoil Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100 4 Braid AL - Aluminum 40 Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (in.) PVC - Polyvinyl Chloride 0.045 Armor Armor Type: Interlocking Armor Material: Aluminum Diameter over Armor: .501 Overall Cable Overall Nominal Diameter: 0.591 in. Mechanical Characteristics (Overall) Operating Temperature Range: -40C To +75C Bulk Cable Weight: 142 lbs/1000 ft. Max. Recommended Pulling Tension: 200 lbs. Min. Bend Radius/Minor Axis: 7.100 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CL2, CM EU Directive 2011/65/EU (ROHS II): Yes EU Directive 2000/53/EC (ELV): Yes Page 1 of 3 08-26-2016Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 123092A Coax - ControlNet Quad Shielded Coax EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 10/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes RG Type: 6/U Flame Test UL Flame Test: UL1685 Vertical Tray Flame Test CSA Flame Test: FT4 Suitability Suitability - Indoor: Yes Suitability - Outdoor: Yes Sunlight Resistance: Yes Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) 75 Nom. Inductance: Inductance (H/ft) .097 Nom. Capacitance Conductor to Shield: Capacitance (pF/ft) 16.2 Nominal Velocity of Propagation: VP (%) 82 Nominal Delay: Delay (ns/ft) 1.28 Nom. Conductor DC Resistance: DCR 20C (Ohm/1000 ft) 28.0 Nominal Outer Shield DC Resistance: DCR 20C (Ohm/1000 ft) 3.6 Nom. Attenuation: Freq. (MHz) Attenuation (dB/100 ft.) 1 .35 2 .38 5 .45 10 .59 20 .86 50 1.37 100 1.97 200 2.82 300 3.48 400 4.04 Max. Operating Voltage - UL: Voltage 300 V RMS Minimum Structural Return Loss: Description Freq. (MHz) Start Freq. (MHz) Stop Freq. (MHz) Min. SRL (dB) 5 50 23 Notes (Overall) Notes: ControlNet is a ControlNet International trademark. Page 2 of 3 08-26-2016