Product: 1153A CATV Video, RG11 Type, 14 AWG BCCS, Quad Shield (Foil + 60% Braid + Foil + 40% Braid), CMP Product Description 14 AWG solid .064 bare copper-covered steel conductor, plenum, foam FEP insulation, Duofoil (100% coverage) + TC braid shields (60% and 40% coverage), FEP jacket. Technical Specifications Product Overview Suitable Applications: CATV, Broadband Physical Characteristics (Overall) Conductor AWG Stranding Material Nominal Diameter No. of Coax 14 Solid BCCS - Bare Copper Covered Steel 0.064 in 1 Conductor Count: 1 Insulation Material Material Trade Name Nominal Diameter FEP - Fluorinated Ethylene Propylene (Foam) Teflon 0.28 in Outer Shield Material Type Layer Material Material Trade Name Coverage % Tape 1 Alum / Poly / Alum Duofoil 100% Braid 2 Tinned Copper (TC) 60% Tape 3 Alum / Poly / Alum Duofoil 100% Braid 4 Tinned Copper (TC) 40% Outer Jacket Material Material Material Trade Name Nominal Diameter FEP - Fluorinated Ethylene Propylene Teflon 0.387 in Electrical Characteristics Conductor DCR Nominal Conductor DCR Nominal Outer Shield DCR Outer Conductor DCR 11 Ohm/1000ft 1.8 Ohm/1000ft 1.8 Ohm/1000ft Capacitance Nom. Capacitance Conductor to Shield 16.2 pF/ft Inductance Nominal Inductance 0.093 H/ft Impedance Nominal Characteristic Impedance75 Ohm Return Loss (RL) Frequency MHz Min. Structural Return Loss (SRL) 5 - 400 MHz 20 dB High Frequency (Nominal/Typical) Frequency MHz Nom. Insertion Loss 1 MHz 0.2 dB/100ft 10 MHz 0.39 dB/100ft 50 MHz 1.2 dB/100ft 100 MHz 1.7 dB/100ft 200 MHz 2.5 dB/100ft 400 MHz 3.5 dB/100ft 700 MHz 4.6 dB/100ft 900 MHz 5.3 dB/100ft 1000 MHz 5.6 dB/100ft Delay Nominal Delay Nominal Velocity of Propagation (VP) % 1.24 ns/ft 82% Voltage UL Voltage Rating 300 V RMS Temperature Range Non-UL Temp Rating: 200C Operating Temp Range: -70C To +200C Mechanical Characteristics Bulk Cable Weight: 94 lbs/1000ft Max. Pull Tension: 212 lbs Min Bend Radius/Minor Axis: 3.9 in Standards NEC/(UL) Compliance: CL2P, CMP CEC/C(UL) Compliance: CMP RG Type: 11/U Type Series Type: 11 Applicable Environmental and Other Programs Environmental Space: Indoor - Plenum EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/96/EC (BFR): Yes EU Directive 2011/65/EU (ROHS II): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive Compliance: EU Directive 2003/11/EC (BFR) EU CE Mark: Yes EU RoHS Compliance Date (yyyy-mm-dd): 2005-04-01 MII Order 39 (China RoHS): Yes Suitability Suitability - Aerial: Yes - When supported by messenger wire Suitability - Burial: Yes Suitability - Hazardous Locations: No Suitability - Indoor: Yes Suitability - Outdoor: Yes Flammability, LS0H, Toxicity Testing