Alpha Wire 711 Lidgerwood Avenue, Elizabeth, NJ 07207 Tel: 1-800-52 ALPHA (25742), Web: www.alphawire.com Customer Specification PART NO. 9316 Construction Diameters (In) 1) Component 1 1 X 1 COAX a) Conductor 25 (7/.0067) AWG SCW 0.020 b) Insulation 0.020 Wall, Nom. PTFE 0.060 (1) Color(s) Cond Color Cond Color Cond Color 1 CLEAR SPC BRAID Shield,94% Coverage, 2) Shield Min. 3) Jacket 0.010 Wall, Nom.,FEP 0.098 (0.102 Max.) a) Color(s) NATURAL TAN ALPHA WIRE-* P/N 9316 MIL-DTL-17 M17/113-RG 316 12814 E346462 1C 26 AWG SHIELDED 200C (UL) C(UL) CMG FT4 OR AWM b) Print 1971 150C 125V CE ROHS * = Factory Code Note: Product may have c(UL) or CSA markings depending upon plant of manufacture. Applicable Specifications 150C / 125 V 1) UL AWM/STYLE 1971 RMS CMG 200C 2) CSA International C(UL) TYPE CMG 200C FT4 200C / 900 V 3) Military MIL-C-17/113 RG 316/U RMS 4) CE: EU Low Voltage Directive 2006/95/EC Environmental 1) CE: EU Directive 2011/65/EU(RoHS2): This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011. No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire s web site for RoHS C of C. 2) REACH Regulation (EC 1907/2006): This product does not contain Substances of Very High Concern (SVHC) listed on the European Union s REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha s REACH SVHC Declaration. The outer surface materials used in the manufacture of this part meet the 3) California Proposition 65: requirements of California Proposition 65. Properties Physical & Mechanical Properties 1) Temperature Range -55 to 200C 2) Bend Radius 10X Cable Diameter 3) Pull Tension 2.11 Lbs, Maximum Electrical Properties (For Engineering purposes only) 900 V 1) Voltage Rating RMS 2) Characteristic Impedance 50 +/- 2 3) Ground Capacitance 29.3 pf/ft 1 kHz, Nominal 4) Velocity of Propagation 70 % 5) Conductor DCR 85.8 /1000ft 20C, Nominal 6) OA Shield DCR 8.5 /1000ft 20C, Nominal 7) Voltage Withstanding 2 kV, Minimum 8) Corona Extinction 1.2 kV, Minimum 9) SRL 30 db 50 MHz 30 100 MHz 23 400 MHz 21 1 GHz 17 db 3 GHz 10) Attenuation, Max dB/100ft 7.5 50 MHz